ECB violations
23-35 Broadway, Queens • Block 00567 • Lot 0007
21 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Oct 1, 2024 | 37029946K | ACTIVE | CLASS - 1 | FAILURE TO SUBMIT THE REQUIRED PARKING STRUCTURE INITIAL OBSERVATION REPORT FOR AN EXISTING PARKING STRUCTURE DOCUMEN... | $12,500 | $12,500 | Nov 10, 2025 |
| Feb 16, 2023 | 35411071L | RESOLVE | CLASS - 1 | FAILURE TO NOTIFY THE DEPT 72HRS PRIOR TO THE COMMENCEMENT OF WORK.AT TIME OF INSPECTION RELATED TO WORK UNDER PERMIT... | $0 | $0 | Jun 6, 2023 |
| Sep 27, 2018 | 38261520X | RESOLVE | CLASS - 2 | 97X17. ELEVATOR FAILURE TO MAINTAIN SERVICE EQUIPMENT UPON INSPECTION DEVICE IS OUT OF SERVICE CREATING A HAZARDOUS, ... | $312 | $0 | Jan 22, 2019 |
| Aug 19, 2017 | 38257402N | RESOLVE | CLASS - 2 | 29H01,67X10 (29H01)ADJUST CHAINE (67X10) REPAIR PHONE | $0 | $0 | Oct 3, 2017 |
| May 11, 2016 | 35112133H | ACTIVE | CLASS - 3 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS. JOB#420238772 PAA DWG. DATED 01/04/15. NOTED: 1-BOILER ROOM... | $500 | $0 | Dec 6, 2016 |
| Mar 5, 2009 | 34766190K | ACTIVE | CLASS - 2 | APPROVED PLACE OF ASSEMBLY PLANS NOT AVAILABLE FOR INSPECTION. REMEDY:PROVIDE APPROVED PLACE OF ASSEMBLY PLANS. | $500 | $0 | Jan 5, 2010 |
| Mar 5, 2009 | 34766189N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: LACK OF EMERGENCY POWER OR STORAGE BATTERY TO EXIT SIGN. NOTED... | $4,800 | $0 | Jan 5, 2010 |
| Nov 21, 2008 | 34750601J | ACTIVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.AT EAST EXPOSURE COURTYARD APPROX 8'WIDE X 16' DEEP X 8' HIGH A/C CON... | $1,200 | $0 | Oct 27, 2009 |
| Nov 21, 2008 | 34750600H | ACTIVE | CLASS - 1 | OPERATION OF PLACE OF ASSEMBLY W/O A CURRENT CERTIFICATE OF OPERATION FOR PA FILING #402542441 APPROVED 5/15/2007.NO ... | $1,600 | $0 | Oct 27, 2009 |
| Nov 20, 2008 | 34703823N | ACTIVE | CLASS - 3 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS FOR ALTII JOB #402541380. CONTRARY PLAN DOES NOT SHOW THREE ... | $200 | -$138 | Jan 13, 2009 |
| Mar 23, 2007 | 34571063H | RESOLVE | Non-Hazardous | USE OR INSTALLATION OF PLUMBING MATERIALS OR EQUIPMENT WHICH DO NOT COMPLY WITH RS-16.IN CELLAR OF GYM PVC DRAIN LINE... | $200 | $0 | May 29, 2007 |
| Dec 12, 2006 | 34546988P | RESOLVE | Non-Hazardous | TOTAL OBSTRUCTION.NOTED:IN FRONT OF PREMISES.FIRE ESCAPES ON RIGHT HAND SIDE OF BLDG AT 1ST FL BLOCKED BY SAND AND DI... | $480 | $0 | Jan 30, 2007 |
| Jun 14, 2006 | 34527648P | ACTIVE | Non-Hazardous | OPERATIONS OF PUBLIC ASSEMBLY WITHOUT CURRENT PERMIT.NOTED:AT THE INSPECTION NO PUBLIC ASSEMBLY PERMIT.POSTED FOR FIT... | $200 | $0 | Jun 26, 2007 |
| Jun 14, 2006 | 34527649R | RESOLVE | Non-Hazardous | FAILURE TO POST CAPACITY SIGN.NOTED:AT THE TIME OF INSPECTION CAPACITYSIGNS NOT POSTED.REMEDY:POST CAPACITY SIGNS. | $40 | -$66 | Jun 26, 2007 |
| Nov 19, 2003 | 34408821H | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE ELEVATOR LANDING 39 SIGNS AT EACH FLOOR IN CASE OF FIRE USE STAIRWELL 393 FAILURE TO PROVIDE 3' EL... | $0 | $0 | Jan 6, 2004 |
| Jul 12, 1991 | 38014204X | RESOLVE | Non-Hazardous | 57O | $150 | $0 | Jan 22, 1992 |
| Jul 12, 1991 | 38014203Y | RESOLVE | Non-Hazardous | 73X,73 RESTORE TO SERVICE FOR THE PURPOSE OF INSPECTION | $150 | $0 | Jan 22, 1992 |
| Aug 29, 1990 | 38000167Z | RESOLVE | Non-Hazardous | 08V,14L,20L,74#,74-FIVE YEAR TEST. | $0 | $0 | Oct 30, 1990 |
| Aug 29, 1990 | 38000168K | RESOLVE | Non-Hazardous | 14M,08V | $0 | $0 | Oct 30, 1990 |
| Jul 10, 1990 | 38000135Y | RESOLVE | Non-Hazardous | 14M,08V,21X,73#, #(73)FIVE YEAR TEST AND FILE ELV 3. | $150 | $0 | Oct 2, 1990 |
| Jul 10, 1990 | 38000134M | RESOLVE | Non-Hazardous | 73X,73#,08V,14L,20L, #(73) FIVE YEAR TEST AND FILE ELV 3 #(20)ALL FLOORS (INDICATORS). | $150 | $0 | Oct 2, 1990 |