27-10 Newtown Avenue, Queens
Queens • Block 00575 • Lot 0002 • Zip: 11102
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 3 days ago- Times Square 27 min 4 walking, 23 riding
- Grand Central 27 min 4 walking, 23 riding
- Union Square 32 min 4 walking, 28 riding
- Penn Station 35 min 4 walking, 31 riding
- Fulton Street 40 min 4 walking, 36 riding
- Downtown Brooklyn 47 min 4 walking, 43 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Railroad
Ferry
Bus
Citi Bike
Places nearby
Between The Bagel
No description yet
Jin Broth
No description yet
Bohemian Hall & Beer Garden
No description yet
Andrew Bellucci’s Pizzeria
Andrew Bellucci’s Pizzeria in Astoria, NY offers authentic New York-style pizza made with fresh ingredients and a sec...
Macoletta
No description yet
El Lado Taco
No description yet
Butcher Bar
No description yet
Elias Corner
Elias Corner in Astoria offers a diverse menu of Mediterranean and American cuisine in a cozy and welcoming atmospher...
Activity
Sales, filings, permits and violations from every dataset, in one order.
2026
-
HPD violation Jan 29, 2026
Class C
§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL...
2025
-
HPD violation Dec 8, 2025
Class B
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOOR LATCH AND ASSEMBLY AT COMPACTOR CLOSET, 6th STORY
2024
-
HPD violation Oct 24, 2024
Class B
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER WINDOW SASH IN THE KITCHEN ...
-
HPD violation Oct 24, 2024
Class C
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STO...
-
HPD violation Oct 24, 2024
Class C
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th ...
-
HPD violation Oct 24, 2024
Class C
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT COMPACTOR CLOSET, 5th STORY
2022
-
DOB violation Aug 2, 2022
BENCH-FAILURE TO BENCHMARK NONE
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
-
CLASS - 2
PIPE LEAKING LEFT REAR OF BLR,SUPPLY PUMP MUST BE INTERLOCKED WITH BNR,MISSING VENT LIMINATOR,CANNOT HAVE 2-LOW WTR C...
-
CLASS - 2
WORK WITHOUT PERMIT INSTALLED IC BURNER MODEL MMG-42P SERIAL#65045-1 CORRECT AND SEND IN CERTIFICATE OF CORRECTION
-
CLASS - 2
RAYPACK BOILER HAS EXPOSED WIRES COMPLETLY APART MISSING CONTROLS ,CORRECT VIOLATION & SEND IN CERTIFICATE OF CORRECTION
2021
-
DOB violation Dec 1, 2021
EGRADE-FAILURE TO POST ENERGY GRADE/SCORE NONE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
-
CLASS - 1
CEASE USE;42M07,70Z02,67L10,C/U 2L10:NO DOOR LOCK MONITORING INSTALLEDIN THIS CONTROLLER AS MANDATED BY 3.10.12 OF AP...
-
CLASS - 2
HEATING SYSTEM- BOILER ROOM SIGN WITH CONTACT INFORMATION NOT VISIBLE FROM FRONT DOOR CORRECT VIOLATING CONDITION AND...
-
DOB violation Jun 2, 2021
BENCH-FAILURE TO BENCHMARK NONE
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
-
DOB violation Apr 29, 2021
EGRADE-FAILURE TO POST ENERGY GRADE/SCORE NONE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
2019
-
DOB violation Nov 8, 2019
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
-
Alteration Type III
LEGALIZE STUCCO WORK AS PER PLAN TO REMOVE VIOLATION # 35345751M .NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APP...
-
CLASS - 2
FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION#35345751M ISSUED ON 7-24-18 AND TO FILE...
-
DOB violation May 2, 2019
BENCH-FAILURE TO BENCHMARK NONE
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
2017
-
Alteration Type II
INSTALLATION OF WASHERS, DRYERS AND REQUIRED SPRINKLER HEAD OVER DRYERS ON CELLAR FLOOR, FOR TENANTS USE ONLY, ACCESS...
2016
2014
-
Alteration Type III
BRICK REPLACEMENT ON PARAPET WALL AS PER PLAN.NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
-
Alteration Type III
PROPOSED INSTALLATION OF PIPE SCAFFOLD FOR REMEDIAL REPAIRS AS PER PLANS. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER ...
-
Alteration Type III
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED FILED FOR REMEDIAL REPAIRS AS PER PLANS. NO CHANGE IN USE OCCUPANCY...
2009
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Registration Contracts
Contact information from multiple dwelling registrations
Building Permits
Owner information from Department of Buildings filings
Recent Building Permits
Owner information from recent DOB NOW filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records