ECB violations
31-74 29 Street, Queens • Block 00579 • Lot 0087
24 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Nov 15, 2025 | 35717988P | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING FACADE WALLS AND APPURTENANCES.NOTE:AT THE TIME OF INSPECTION I OBSERVED AT EX#1 EAST EL... | $2,530 | $0 | Jan 20, 2026 |
| Aug 25, 2020 | 39027524Y | RESOLVE | CLASS - 2 | PHONE IN CAB INOPERATIVE. REPAIR. FIRE SERVICE BUZZER INOPERATIVE. REPAIR. FIRE EXTINGUISHER HAS NO EXPIRATION TAG. P... | $0 | $0 | Oct 13, 2020 |
| Jun 13, 2019 | 35437235Y | RESOLVE | CLASS - 2 | FAILED TO NOTIFY DEPT PRIOR TO INSTALLATION OF SUSPENDED SCAFFOLD. NOTE AT THE TIME OF MY INSPECTION, I OBSERVED SUSP... | $0 | $0 | Aug 20, 2019 |
| Mar 8, 2016 | 38241095X | RESOLVE | CLASS - 1 | 67X10,05X10,59X10. 67X10-REPROGRAM EMERGENCY PHONE; 05X10-REPAIR DOOR ZONE LOCK; 59X10-REPAIR (ADJUST) BRAKE MONITORI... | $1,000 | $0 | Apr 19, 2016 |
| Apr 16, 2014 | 36018813R | RESOLVE | CLASS - 2 | FAILUER TO FILE AN ACCEPTABLE CYCLE 7 TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXT... | $800 | $0 | Oct 21, 2014 |
| Jun 29, 2011 | 34914049N | RESOLVE | CLASS - 2 | WORK W/O A PERMIT. WORK NOTED AS FOLLOW: AT BASEMENT LEVEL (LOBBY) (1) FULL HEIGHT PARTITION WALLS ERECTED CREATING 1... | $0 | $0 | Dec 13, 2011 |
| Jun 29, 2011 | 34914048L | RESOLVE | CLASS - 2 | RESIDENCE ALTERED FOR OCCUPANCY AS DWELLING FOR MORE THAN THE LEGALLY APPROVED # OF FAMILIES. MDR #400769 APD RECORDS... | $0 | $0 | Dec 13, 2011 |
| May 10, 2011 | 34913678L | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED PLANS. UPON INSPECTION I OBSERVED THAT A GAS BOOSTER IS INSTALLED BUT NOT SHOWN ON ... | $500 | $0 | Sep 13, 2011 |
| Mar 4, 2011 | 34894982P | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED. UPON INSPECTION I OBSERVED 4 GAS FIRED DRYERS INS... | $1,000 | $0 | Oct 18, 2011 |
| Mar 4, 2011 | 34894986M | RESOLVE | CLASS - 1 | GAS BEING SUPPLIED TO BLDG W/O INSP & CERTIFICATION BY DOB.@ TIME OF INSP I OBSERVED 6" AND 4" WELDED GAS PIPE INSTAL... | $1,000 | $0 | May 31, 2011 |
| Mar 4, 2011 | 34894983R | RESOLVE | CLASS - 2 | USE OR INSTALLATION OF PLUMBING MATERIALS OR EQUIPMENT WHICH DO NOT COMPLY W/RS-16. UPON INSPECTION I OBSERVED FOUR G... | $250 | $0 | Apr 19, 2011 |
| Nov 4, 2009 | 38207210N | RESOLVE | CLASS - 2 | 42G11 69M07 24X10 39Q03 77Q03 24X10 -PI INDICATOR ON 4TH FL INOPERATIVE 39Q03 -TOP OF AL CAR LIGHT UNGUARDED 77Q03 - ... | $500 | $0 | Dec 29, 2009 |
| Nov 4, 2009 | 38207209X | RESOLVE | CLASS - 2 | 24X10 98M07 39I10 69M07 70O02 24X10 -POWER INDICATORS INOPERATIVE 39I10 -TOP OF A CAR LIGHT FIXTURE DAMAGED REPAIR OR... | $500 | $0 | Dec 29, 2009 |
| Nov 28, 2008 | 36005753L | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF E... | $400 | $0 | Mar 9, 2010 |
| Mar 24, 2006 | 38158325P | RESOLVE | Non-Hazardous | 21J01/51O02. 21- 6TH FL INTERLOCK SHUTS CAR DOWN IN FLIGHT. | $0 | $0 | May 9, 2006 |
| Mar 24, 2006 | 38158149P | RESOLVE | Non-Hazardous | 41G09/39O02/44O02/51O02/55O02. 41- REMOVE JUMPERS FROM FUSES. | $0 | $0 | May 9, 2006 |
| May 5, 2004 | 34460448R | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT:PERIODIC INSPECTION OF EXTERIOR WALLS AND APPRURTENANCES AS REQUIRED... | $0 | $0 | Jun 29, 2004 |
| Jan 27, 2003 | 32040863K | RESOLVE | Non-Hazardous | 50A DOOR OF BOILER ROOM IS REPUIRED TO SWING OUT OPENING EGRESS. | $0 | $0 | Mar 18, 2003 |
| Mar 3, 1998 | 38070772K | RESOLVE | Non-Hazardous | 52H12-REPLACE BRAKE LINING. | $0 | $0 | Apr 21, 1998 |
| Mar 3, 1998 | 38070773M | RESOLVE | Non-Hazardous | 22D6. | $0 | $0 | Apr 21, 1998 |
| Mar 28, 1994 | 38040434K | RESOLVE | Non-Hazardous | 09M,11Q,22D,36L,15L, (09) PROVIDE TWO GIBS IN CAR DOOR. (15) REPAIR LOBBY HOISTWAY DOOR AND PROVIDE ELEVATOR SERVICE ... | $0 | $0 | May 10, 1994 |
| Mar 28, 1994 | 38040433Z | RESOLVE | Non-Hazardous | 11Q,36L,09M, (36) REPAIR DOOR & PROVIDE A PROPER LOCK (09) PROVIDE TWO GIBS ON CAR DOOR | $0 | $0 | May 10, 1994 |
| Apr 2, 1991 | 38009792P | RESOLVE | Non-Hazardous | 13M,18L, (18) 6TH FLOOR. | $0 | $0 | Sep 3, 1991 |
| Apr 2, 1991 | 38009791N | RESOLVE | Non-Hazardous | 21X,57O, | $0 | $0 | Sep 3, 1991 |