ECB violations
35-01-35-11 36 Avenue, Queens • Block 00639 • Lot 0001
51 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Oct 28, 2024 | 39533877L | RESOLVE | CLASS - 2 | UPON INSPECTION OF AN ACTIVE 9 STORY NB AND AFTER REVIEW OF THE APPROVED SITE SAFETY PLAN WORK WAS DETERMINED TO BE I... | $1,250 | $0 | Jun 16, 2025 |
| Oct 28, 2024 | 39533871K | RESOLVE | CLASS - 2 | AT THE TIME OF MY INSPECTION I OBSERVED A CONSTRUCTION FENCE INSTALLED AT EXPOSURE 1 AND 2 NOT MAINTAINED OR INSTALLE... | $1,000 | $0 | Jun 16, 2025 |
| Oct 28, 2024 | 39533876J | RESOLVE | CLASS - 2 | I OBSERVED PEDESTRIAN PROTECTION (SIDEWALK SHED) NOT MAINTAINED IN A SAFE CONDITION CONTRARY TO CODE 3307.6.5.1. RUST... | $2,400 | $0 | Jun 16, 2025 |
| Oct 28, 2024 | 39533881Y | RESOLVE | CLASS - 2 | I OBSERVED PEDESTRIAN PROTECTION (SIDEWALK SHED) INSTALLED CONTRARY TO CODES: 3307.6.4.4-MULTIPLE VERTICAL BEAMS INST... | $2,400 | $2,400 | Jan 7, 2025 |
| Jul 18, 2024 | 39530634N | RESOLVE | CLASS - 2 | OBSERVED CONSTRUCTION FENCE AT SEVERAL EXPOSURES, PERMIT Q00364769-I1-FN EXPIRED 04/01/2024. PERMITHOLDER FAILED TO R... | $625 | $0 | Feb 4, 2025 |
| Apr 9, 2024 | 39527303L | RESOLVE | CLASS - 1 | OBSERVED 9 STR/140 FT NEW BUILDING UNDER CONSTRUCTION- ACTIVE SITE W/ APROX. 15 WORKERS ON SITE. UPON REVIEW OF DEPAR... | $5,000 | $5,000 | Oct 31, 2025 |
| Sep 20, 2023 | 39521915P | RESOLVE | CLASS - 2 | I OBSERVED SF AT ALL 4-EXP INSTALLED CONTRARY TO PLANS-USING 2-5' HIGH MASONARY FRAMES ON BASE(1ST ROW)-NOT ON PLANS(... | $0 | $0 | Nov 28, 2023 |
| Sep 20, 2023 | 39521916R | RESOLVE | CLASS - 1 | AT THE TIME OF MY INSPECTION OF 10 STORY NEW BUILDING I OBSERVED INADEQUATE GUARDRAIL SYSTEM ON ROOF AT CORNERS OF EX... | $5,000 | $5,000 | Jan 16, 2024 |
| Aug 14, 2023 | 39520535Z | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OF DEPARTMENT RECORDS NO COMPLIANCE WAS RECORDED FOR INCIDENT 5-12-2023. | $2,500 | $2,500 | Oct 24, 2023 |
| May 12, 2023 | 35654007N | RESOLVE | CLASS - 1 | FAILURE TO NOTIFY THE DEPARTMENT OF AN ACCIDENT INCIDENT THAT RESULTEDIN A FATALLY OR AN INJURY.A WORKER FALL OFF A F... | $2,500 | $2,500 | Feb 6, 2024 |
| Apr 25, 2023 | 39515809K | RESOLVE | CLASS - 1 | & INDUSTRY SAFETY STANDARD FOR SAFE LADDER USE.@9 STORY NB SITE IN RESPONSE TO INTERIOR FRAMER/CARPENTER WORKER FELL ... | $2,500 | $2,500 | Feb 6, 2024 |
| Mar 20, 2023 | 39514372M | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION, OBSERVED UNPROTECTED MECHANICAL VENT AT EXPOSURE 3 AND UNPROTECTED ANTENNA DISH AT EXPOSUR... | $0 | $0 | May 30, 2023 |
| Mar 20, 2023 | 39514371K | RESOLVE | CLASS - 2 | UPON REVIEW OF APPROVED SCAFFOLD/NEEDLE BEAM PLANS, SITE CONDITION DID NOT CONFORM TO THE APPROVED PLAN. SITE CONDITI... | $0 | $0 | May 30, 2023 |
| Jan 16, 2023 | 39511704X | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION AT AN ACTIVE JOBSITE, IT WAS OBSERVED FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING WITH CONSTRUCTI... | $0 | $0 | Apr 25, 2023 |
| Jan 16, 2023 | 39511700Z | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION AT AN ACTIVE JOBSITE IT WAS OBSERVED SCAFFOLD HAS NOT BEEN INSTALLED AND MAINTAINED AS PER CODE... | $0 | $0 | Apr 25, 2023 |
| Jan 16, 2023 | 39511705H | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION AT AN ACTIVE JOBSITE IT WAS OBSERVED FAILURE TO ROVIDE TREE PROTECTION AT EXPOSURE-2 (35TH STRE... | $0 | $0 | Apr 25, 2023 |
| Dec 21, 2022 | 39510674J | RESOLVE | CLASS - 2 | TIME OF INSPECTION AT 9 STORY NEW BUILDING OPEN ACTIVE SITE OBSERVED SUPPORTED SCAFFOLD INSTALLED AT ALL EXPOSURE. UP... | $0 | $0 | Apr 25, 2023 |
| Jul 15, 2022 | 39503632X | RESOLVE | CLASS - 2 | FAILURE TO TEMPORARY ELEVATOR CERTIFICATE AS REQUIRED. I OBSERVED TEMPORARY ELEVATOR /HOIST INSTALLED WITH CERTIFICAT... | $1,250 | $1,250 | Apr 11, 2023 |
| Jul 15, 2022 | 39503611R | RESOLVE | CLASS - 1 | AT TIME OF MY INSPECTION RESPONDING TO COMPLAINT THAT SIDEWALK SHED ROOF PARAPET DAMAGE HIT BY TRUCK AT 35 STREET AND... | $0 | $0 | Apr 11, 2023 |
| Jul 15, 2022 | 39503628N | RESOLVE | CLASS - 2 | I OBSERVED 9 STORY BUILDING ROOF LEVEL UNDER CONSTRUCTION WORKING IN PROGRESS WITH WORK NOT CONFORM AS PER APPROVED S... | $1,250 | $1,250 | Apr 11, 2023 |
| Jul 15, 2022 | 39503633H | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE WATCHPERSON AS REQUIRED: AT TIME OF MY INSPECTION OBSERVED 9 STORY BUILDING ROOF LEVEL UNDER CONST... | $2,500 | $2,500 | Apr 11, 2023 |
| Apr 16, 2022 | 35646150X | RESOLVE | CLASS - 1 | FAILED TO PROVIDE WATCH PERSON.NOTE:AT THE TIME OF MY INSPECTION OF A NEW 9 STORY BUILDING WITH APPROXIMATELY 6774 SQ... | $2,500 | $2,500 | Jan 4, 2023 |
| Apr 16, 2022 | 35646199R | RESOLVE | CLASS - 1 | BC 3307.4.7 WORK AND STORAGE ZONE NOTE:AT THE TIME OF MY INSPECTION OFA 9 STORY BUILDING NO ACTIVE CONSTRUCTION SITE ... | $6,250 | $6,250 | Sep 5, 2023 |
| Dec 27, 2021 | 35641975H | RESOLVE | CLASS - 2 | BC3314.1 INADEQUATE SUPPORT SCF.ATO MY INSP ON 9STYNB I OBSERVED ACTIVE SITE W/SSM ONSITE.ALSO OBSERVED SUPPORTED SCF... | $0 | $0 | Mar 29, 2022 |
| Dec 27, 2021 | 35641976J | RESOLVE | CLASS - 2 | WORK CONTRARY TO APPROVED/ACCEPTED DOCS/DRAWING-ATO MY INSP ON NB9STY MIXUSE I OBSERVED NEEDLE BEAMS ON 3FL LEVEL.UPO... | $0 | $0 | Mar 29, 2022 |
| Dec 27, 2021 | 35641699K | RESOLVE | CLASS - 2 | BC3309.10 INADEQUATE ROOF PROTECTION.ATO MY INSP ON 9STYNB,I OBSERVED ACTIVE SITE W/SSM ONSITE.ALSO OBSERVED INADEQUA... | $0 | $0 | Mar 29, 2022 |
| Oct 19, 2021 | 35505485Z | RESOLVE | CLASS - 1 | WORK DOESNT CONFORM TO APPROVED CONST DOCS &/OR APPROVED AMENDMENTS.ATOI OF PROPOSED 9STYNB UNDER CONST (6FL POURED/8... | $625 | $625 | May 24, 2022 |
| Oct 19, 2021 | 35505486K | RESOLVE | CLASS - 1 | WORK DOESNT CONFORM TO APPROVED CONST DOCS &/OR APPROVED AMENDMENTS.ATOI OF PROPOSED 9STYNB UNDER CONST,(6FL POURED, ... | $625 | $625 | May 24, 2022 |
| Oct 19, 2021 | 35505487M | RESOLVE | CLASS - 1 | FAILURE TO PERFORM SUCCESSFUL HYDROSTATIC PRESSURE TEST OF STANDPIPE SYSTEM.ATOI OF PROPOSED 9STYNB UNDER CONST (6FL ... | $5,000 | $5,000 | May 24, 2022 |
| Oct 19, 2021 | 35505488Y | RESOLVE | CLASS - 1 | WORK DOESNT CONFORM TO APPROVED CONST DOCS &/OR APPROVED AMENDMENTS.ATOI OF PROPOSED 9STYNB UNDER CONST (6FL POURED,8... | $625 | $625 | May 24, 2022 |
| Oct 19, 2021 | 35505489X | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SEC REQUIREMENTSATOI OF PROPOSED 9STYNB UNDER CONST (6FL POURED,8TH WOR... | $0 | $0 | Jan 18, 2022 |
| Oct 15, 2021 | 35506013P | RESOLVE | CLASS - 1 | FAILURE TO SAFETY EQUIPMENT MEASURE NOTE:AT THE TIME OF MY INSPECTION RESPONDING TO COMPLIANT WHERE A WORKER GOT INJU... | $2,500 | $2,500 | Jun 7, 2022 |
| Oct 15, 2021 | 35506016K | RESOLVE | CLASS - 1 | BC 3314.4 FAILURE TO PROVIDE PROPER INSPECTION NOTE:AT TIME OF MY INSPECTION OBSERVED SUPPORTED PIPE SCAFFOLD INSTALL... | $625 | $625 | Jun 7, 2022 |
| Oct 15, 2021 | 35506014R | RESOLVE | CLASS - 1 | PRE-SHIFT SAFETY MEETING CONTENT.NOTE:AT TIME OF MY INSPECTION RESPONDING TO COMPLAINT THAT WHERE ONE WORKER GOT INJU... | $625 | $625 | Jun 7, 2022 |
| Oct 15, 2021 | 35506015Z | RESOLVE | CLASS - 1 | BC 3314.1 FAILURE TO MAINTAIN SUPPORTED PIPE SCAFFOLD NOT GUARDRAILS INADEQUATE PLATFORM.NOTE:AT TIME OF MY INSPECTIO... | $2,500 | $2,500 | Jun 7, 2022 |
| Oct 5, 2021 | 35538135J | RESOLVE | CLASS - 1 | BC 1905.6.3.3 FINAL CURING:FAILURE TO PROPERTY LABORATORY CURE CONCRETE CYLINDERS IN ACCORDANCE WITH ASTM C31.10.1.2,... | $1,250 | $0 | Aug 22, 2022 |
| Jul 2, 2021 | 39043932N | RESOLVE | CLASS - 1 | AT TIME OF INCIDENT, CRANE CD4794 UNDER CN961/20 ON SITE. CRANE FLIPPED OVER ONTO BUILDING DUE TO HMO DISREGARDING CR... | $10,000 | $10,000 | Jul 12, 2022 |
| Jul 2, 2021 | 39043931L | RESOLVE | CLASS - 1 | AT TIME OF INCIDENT, CRANE CD4794 UNDER CN961/20 ON SITE. CRANE PICKING STEEL COLUMN AT A RADIUS OUTSIDE OF THE CRANE... | $10,000 | $10,000 | Jul 12, 2022 |
| Jul 2, 2021 | 39043907L | RESOLVE | CLASS - 1 | AT TIME OF INCIDENT, HMO KEITH BROWN #8082, OPERATING CD4794 UNDER CN961/20, FLIPPED THE CRANE SIDEWAYS ONTO THE BUIL... | $0 | $0 | Aug 17, 2021 |
| Jul 2, 2021 | 35574926Y | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS.NOTE:AT TIME OF INSPECTION RESPONDI... | $5,000 | $5,000 | May 17, 2022 |
| Jul 2, 2021 | 39043930J | RESOLVE | CLASS - 1 | AT TIME OF INCIDENT, USER OF CRANE CD4794 UNDER CN961/20, CLASSIC IRON DESIGNS, WAS ATTEMPTING TO HOIST A STEEL CLOUM... | $0 | $0 | Oct 5, 2021 |
| Jul 2, 2021 | 39043903Y | RESOLVE | CLASS - 1 | AT TIME OF INCIDENT, HMO KEITH BROWN #8082, OPERATING CD4794 UNDER CN961/20, KNOWINGLY PICKED A STEEL COLUMN WEIGHING... | $10,000 | $9,920 | Aug 17, 2021 |
| Jul 2, 2021 | 35574925M | RESOLVE | CLASS - 1 | PERMIT HOLDER FAILURE TO ENSURE ALL WORKERS RECEIVE SITE SAFETY ORIENTATION.NOTE:AT TIME OF INSPECTION RESPONDING TO ... | $2,500 | $0 | Nov 30, 2021 |
| Jul 2, 2021 | 39043908N | RESOLVE | CLASS - 1 | AT TIME OF INCIDENT, LIFT DIRECTOR ONSITE OF CD4794 UNDER CN961/20, RODNEY BABWAH , FAILED TO PERFORM DUTIES. HOISTIN... | $10,000 | $0 | Aug 17, 2021 |
| Jun 29, 2021 | 35575764P | RESOLVE | CLASS - 2 | BC330747-WORK OR STORAGE ZONE.NOTE:AT THE TIME OF MY INSPECTION OF AN ACTIVE 9 STORY NEW BUILDING CURRENTLY AT 2ND FL... | $0 | $0 | Sep 21, 2021 |
| Jun 21, 2021 | 35574346H | RESOLVE | CLASS - 2 | YODOCKS NOT LOCKED IN PLACE OR WATERFILLED AS PER MANUFACTURER SPECIFICATIONS.AT THE TIME OF INSPECTION OF A PROPOSED... | $0 | $0 | Sep 14, 2021 |
| Jun 21, 2021 | 35574345X | RESOLVE | CLASS - 2 | INADEQUATE WORK/STORAGE ZONE AT THE TIME OF INSPECTION OF A PROPOSED 9STORY NEW BUILDING AT 2ND STORY FRAMING ACTIVE ... | $625 | $0 | Nov 30, 2021 |
| Jun 21, 2021 | 35574347J | RESOLVE | CLASS - 1 | BC 3307.1 FAILURE TO OBTAIN DOT PERMIT FOR A CRANE PLACEMENT ON STREETAT THE TIME OF INSPECTION OF A PROPOSED & STORY... | $625 | $625 | May 17, 2022 |
| Mar 2, 2021 | 35549818M | RESOLVE | CLASS - 1 | CONTRACTOR'S LICENSE EXPIRED.AT THE TIME OF MY INSPECTION AT A 9 STORYBUILDING UNDER CONSTRUCTION,I OBSERVED CONSTRUC... | $625 | $0 | Sep 28, 2021 |
| Mar 2, 2021 | 35549819Y | RESOLVE | CLASS - 1 | EARTHWORK NOTIFICATION NUMBER EXPIRED.AT THE TIME OF MY INSPECTION AT A 9 STORY BUILDING UNDER CONSTRUCTION CURRENTLY... | $2,500 | $0 | Sep 28, 2021 |