ECB violations
44 Street, Queens • Block 00709 • Lot 0028
27 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Mar 21, 2022 | 39058465P | ACTIVE | CLASS - 1 | DLM IMPROPERLY INSTALLED ON THIS DEVICE . NO FIREMAN'S SERVICE PRESENT IN CONTROLLER . INSTALL FIREMAN'S SERVICE SO D... | $1,250 | $1,250 | Dec 18, 2026 |
| Dec 16, 2019 | 35424452H | RESOLVE | CLASS - 1 | FAILURE TO NOTIFY THE DEPT OF AN ACCIDENT OR INCIDENT THAT RESULTED INA FATALITY OR INJURY. NOTE:A WORKER WAS UNLOADI... | $5,000 | $0 | Mar 16, 2021 |
| Oct 9, 2019 | 35449419R | RESOLVE | CLASS - 2 | BC3314102/BC3314109-INADEQUATE SUPPORT,AND HORIZONTAL TIEBACK LOCATIONS FOR OUTRIGGER SCAFFOLD AND C-HOOK SCAFFOLDS.-... | $0 | $0 | Jul 20, 2021 |
| Oct 1, 2019 | 35424175Z | RESOLVE | CLASS - 1 | 3314.6.3 FAILURE TO MAINTAIN SAFETY MEASURE FOR TIEBACKS AND LIFE LINES ATTACHED TO SAME POINT OF ANCHORAGE. NOTE:AT ... | $2,500 | $0 | Oct 5, 2021 |
| Oct 1, 2019 | 35447269L | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PUBLIC AND PROPERTY AFFECTED BY CONSTRUCTION OPERATION. NOTE:AT TIME OF MY INSPECTION OF A 6... | $5,000 | $0 | Oct 5, 2021 |
| Oct 1, 2019 | 35424176K | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN SAFETY MEASURE ALL PERSON AND PROPERTY AFFECTED BYCONSTRUCTION. NOTE:AT TIME OF MY INSPECTION OF ... | $2,500 | $0 | Oct 5, 2021 |
| Oct 1, 2019 | 35447270Z | RESOLVE | CLASS - 1 | FAILURE TO PROMPTLY NOTIFY THE DEPT OF AN ACCIDENT AT CONSTRUCTION SITE. NOTE:AT TIME OF MY INSPECTION OF A 6 STORY B... | $2,500 | $0 | Oct 5, 2021 |
| Oct 1, 2019 | 35447271K | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENT AND/OR APPROVED AMENDMENTS. NOTE:AT TIME OF MY INSPECTION OF ... | $625 | $0 | Oct 5, 2021 |
| Oct 1, 2019 | 35447272M | RESOLVE | CLASS - 1 | FAILURE TO PERFORM SAFE/PROPER INSPECTION OF SUSPENDED SCAFFOLD. NOTE:AT TIME OF MY INSPECTION OF A 6 STORY BUILDING ... | $1,250 | $0 | Oct 5, 2021 |
| Oct 1, 2019 | 35447273Y | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION. NOTE:AT TIME OF MY INSPECTION OF A 6 STORY BUILDING AT FACADE... | $2,400 | $0 | Oct 5, 2021 |
| Oct 1, 2019 | 35447274X | RESOLVE | CLASS - 2 | HOUSEKEEPING. NOTE:AT TIME OF MY INSPECTION OF A 6 STORY BUILDING AT FACADE RENOVATION WORK IN PROGRESS. I OBSERVED T... | $625 | $0 | Oct 5, 2021 |
| Jun 18, 2019 | 37015298Y | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#37010734Z ISSUED ON 5/18/18 AND TO FIL... | $1,250 | $0 | Oct 29, 2019 |
| May 18, 2018 | 37010734Z | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT ACCEPTABLE 8TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS AND APP... | $1,250 | $0 | Oct 9, 2018 |
| May 18, 2016 | 32076091Y | RESOLVE | CLASS - 1 | 02-BOILER INSTALLED W/O PERMIT. RHEEM MOD#RCV1467- 1,467,000 BTUS. OBTAIN PROPER PERMITS AND REGISTER BOILER. | $1,600 | $0 | Aug 9, 2016 |
| May 18, 2016 | 32076092X | RESOLVE | CLASS - 2 | B254,11C,50,50A,50B,50C,50D. 50-SEAL DOOR W/O STEPS; 50A-SUPPORT PIP ING; 50B-INTERLOCK TRANSFER PUMP; 50C-INSTALL SP... | $250 | $0 | Jul 5, 2016 |
| May 6, 2015 | 35115850Y | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.FAILURE TO PROVIDE A SYSTEM OF AUTOMATIC SPRINKLER WHERE REQUIRED O... | $1,000 | $0 | Dec 29, 2015 |
| May 6, 2015 | 35115851X | RESOLVE | CLASS - 1 | WORK NO PERMIT OBSERVED ON MAY 6TH 2015.THE INSTALLATION OF WASHING MACHINE & GAS DRYERS IN LAUNDRY ROOM-SPACE NOT ON... | $0 | $0 | Jul 28, 2015 |
| Jul 30, 2014 | 35099472Z | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONST DOCUMENTS/APPROVED AMEND.NOTE:SIDEWALK SHED HAVE BEEN ERECTED @ EXP #4(44 STR... | $0 | $0 | Sep 16, 2014 |
| Feb 7, 2014 | 35069631J | RESOLVE | CLASS - 2 | WORK W/O A PERMIT. WORK NOTED: AT 4TH FL LEVEL,1 COMBINED APTS 4A & 4BTO BE USED AS 1 APT & 2 COMBINED APTS 4J & 4K T... | $800 | $0 | May 6, 2014 |
| Jan 21, 2011 | 38214683Z | RESOLVE | CLASS - 2 | 77B11 -REPLACE TOE GUARD AS PER K3 21"MIN 100M07-PROVIDE IN CAR COMMUNICATION AS PER K3 | $0 | $0 | Mar 8, 2011 |
| Jan 21, 2011 | 38214682R | RESOLVE | CLASS - 2 | 77B11 100M07 77B-REPLACE TOE GUARD AS PER K3 100M07-IN CAR COMMUNICATION PROVIDE AS PER K3 | $0 | $0 | Mar 8, 2011 |
| Jan 6, 2010 | 38208401K | RESOLVE | CLASS - 2 | 72N7.77Q3.81M7 72M7 PROVIDE PIT STOP AWITCH RETOACTIVE ITEM 77Q3 INSTALL GUARD ON UNDERSIDE THE PLATFORM LIGHT | $500 | $0 | Mar 2, 2010 |
| Oct 23, 1998 | 38080790N | RESOLVE | Non-Hazardous | 73O2,50Y11,8V1. | $0 | $0 | Aug 3, 1999 |
| Oct 20, 1998 | 38080786K | RESOLVE | Non-Hazardous | 73O 50Y 08V | $350 | $0 | Jan 4, 2000 |
| Oct 16, 1996 | 34144649Z | RESOLVE | Hazardous | FAILURE TO MAINTAIN DEFECT IS DEFECTIVE RAILING OF THE REAR FIRE ESCAPE STAIRS A PIECE OF METAL RAILING APPROX 3HIGHX... | $0 | $0 | Jan 14, 1997 |
| Oct 12, 1994 | 38043418Y | RESOLVE | Non-Hazardous | 40H,35R,33M,33R,40 REPAIR PIT GOVERNERNOR TENSION SHERVE REMOVE ALL NOISE TO 33 REMOVE ALL NOW ELEAVOTOR STORAGE IN R... | $0 | $0 | Nov 29, 1994 |
| Oct 12, 1994 | 38043417M | RESOLVE | Non-Hazardous | 17R,28H,36W,35R,33L,33M,REPLACE WITH CLEAR WIRE GLASS TO CAR DOOR VISION PANEL 28 REMOVE NASEAL CAR RUNS 36 REPAIR DO... | $0 | $0 | Nov 29, 1994 |