ECB violations
22-02-22-54 95 Street, Queens • Block 01071 • Lot 0001
37 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Feb 24, 2026 | 39178088P | RESOLVE | CLASS - 1 | CLASS 1 CEASE USE ITEM: DOOR ZONE RESTRICTOR INOPERATIVE. THIS IS A SAFETY FEATURE WHICH ENSURES PASSENGER SAFETY. RE... | $1,250 | $0 | May 5, 2026 |
| Nov 10, 2025 | 39166581K | ACTIVE | CLASS - 2 | NO CERTIFICATE OF CORRECTION FILED FOR VIOLATION NUMBER 39138542J, FILE A CERTIFICATE OF CORRECTION | $1,250 | $1,250 | Jan 20, 2026 |
| Feb 14, 2025 | 39138542J | RESOLVE | CLASS - 1 | UNSAFE STORAGE OF COMBUSTIBLE MATERIAL AND EQUIPMENT. OBSERVED EXCESSIVE UNSAFE STORAGE UNDERNEATH STAIRCASES THROUGH... | $6,250 | $6,250 | Feb 8, 2027 |
| Mar 12, 2024 | 39108504L | RESOLVE | CLASS - 2 | HOLE PENETRATIONS IN GAS/BOILER MECHANICAL ROOM CELLAR LEVEL AND UNPERMITTED PLASTIC ACCESS PANALS THROUGHOUT BUILDIN... | $0 | $0 | May 21, 2024 |
| Feb 29, 2024 | 39107353Z | RESOLVE | CLASS - 2 | OBSERVED CONCEALED SPRINKLER HEAD ESCUTCHEONS HAVING PAINT ON THEM. AS PER 102.3 OF THE PLUMBING CODE MAINTENANCE. IN... | $0 | $0 | Jul 2, 2024 |
| Feb 13, 2024 | 39105866P | RESOLVE | CLASS - 2 | WEIL MCLAIN BOILER. MODEL#1188. BOILER IS MISSING SPILL SWITCH AT THE DRAFT REGULATOR. AND EXHAUST LEAKAGE AT ELBOW O... | $0 | $0 | Jun 14, 2024 |
| Oct 21, 2022 | 39072445Z | RESOLVE | CLASS - 2 | SMOKE ALARM IS DEFECTIVE, CORRECT VIOLATING CONDITION AND SUBMIT A CERTIFICATE OF CORRECTION. | $625 | $0 | Dec 20, 2022 |
| Oct 13, 2022 | 39071904Y | RESOLVE | CLASS - 1 | I OBSERVED WORK BEING PERFORMED UNDER JOB PERMIT #421267220-01-EW-OT , THE SUBMITTED TPP HEALTH REQUIREMENT SECTION D... | $625 | $0 | Nov 29, 2022 |
| Oct 13, 2022 | 39071915J | RESOLVE | CLASS - 2 | OBSERVED IN BASEMENT/CELLAR EXCESSIVE AMOUNTS OF COMBUSTIBLE STORAGE IN THE BOILER ROOM. NO STORAGE SHALL BE KEPT IN ... | $0 | $0 | Nov 29, 2022 |
| Oct 13, 2022 | 39071903M | RESOLVE | CLASS - 2 | AT FIRST FLOOR, EXIT DOOR E, AT CELLAR LEVEL COMMUNITY ROOM DOOR (PUSH BAR) DO NOT CLOSE PROPERLY WHEN INSPECTED. ALS... | $0 | $0 | Nov 29, 2022 |
| Oct 13, 2022 | 39071920Y | RESOLVE | CLASS - 2 | OBSERVED APPROXIMATELY 10 FEET OF CAST IRON PIPE WITH CAST IRON FITTINGS INSTALLED( 2 INCH SWEEP AND 2 INCH WYE) WITH... | $0 | $0 | Apr 25, 2023 |
| Apr 29, 2022 | 35581536Y | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER.ATOI OBSERVED@EXP4@ROOF LEVEL SECS OF FOAM LAMINATED STUCCO HAS DETA... | $0 | $0 | Jul 26, 2022 |
| Sep 29, 2021 | 39048390K | RESOLVE | CLASS - 2 | NO THREADS ON LOW WATER CUTOFF BLOWDOWN PIPING, BACKFLOW PREVENTER MISSING DISCHARGE PIPING. CORRECT ALL VIOLATING CO... | $310 | $0 | Nov 16, 2021 |
| Jan 5, 2021 | 39034331N | RESOLVE | CLASS - 2 | THREADED PIPE ON LOW WATER CUT OFF BLOWDOWN. CORRECT ALL VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION. | $0 | $0 | May 24, 2022 |
| Dec 1, 2020 | 39032789X | RESOLVE | CLASS - 1 | ENTIRE DEVICE INOPERABLE-RETURN TO SERVICE IMMEDIATELY | $0 | $0 | Nov 23, 2021 |
| Feb 10, 2020 | 39017238Y | RESOLVE | CLASS - 2 | I OBSERVED IN THE BASEMENT BOILER ROOM THE INSTALLATION OF A SUB-PANEL WITH FEEDER CONDUCTORS, OVERCURRENT DEVICES, C... | $400 | $0 | Jan 26, 2021 |
| Feb 10, 2020 | 39017237M | RESOLVE | CLASS - 1 | I OBSERVED ON THE ROOF ELECTRICAL RACEWAYS INSTALLED UNDER THE FLASHING ATTACHED TO THE PARAPET WALL NO ACCESSIBLE ME... | $400 | $0 | Jan 26, 2021 |
| Feb 10, 2020 | 39017239X | RESOLVE | CLASS - 1 | I OBSERVED IN THE BASEMENT BOILER ROOM NEAR THE REC. ROOM A DOOR MARKED FOR STORAGE, CORRODED, BROKEN AND DEFECTIVE E... | $400 | $0 | Jan 26, 2021 |
| Dec 24, 2019 | 39014782Y | RESOLVE | CLASS - 1 | DOOR ZONE RESTRICTOR NOT WORKING TAKEN APART, IN CAR PHONE NOT WORKING. | $1,250 | $0 | Feb 15, 2022 |
| Jul 6, 2018 | 35336444H | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES.NOTED:OBSERVED AT EXPOSURE #1 NORTHEAST STONE COLUMN AT MAIN EN... | $3,125 | $0 | Nov 28, 2018 |
| Mar 12, 2018 | 35312870Y | RESOLVE | CLASS - 1 | UNLAWFUL ACTS FAILURE TO COMPLY W/AN ORDER OF THE COMMISSIONER. RECORDS INDICATE NO APPLICATION WAS MADE TO CORRECT &... | $0 | $0 | Oct 23, 2018 |
| Mar 1, 2018 | 35317562P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTED: OBSERVED SPALLING CEMENT STUCCO WHICH IS BULGING AT THE... | $500 | $0 | Apr 17, 2018 |
| Jan 3, 2018 | 35297135P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. NOTED: @ BASEMENT LEVEL, IN ELECTRICAL ROOM, THERE ARE SEVERAL CRA... | $250 | $0 | May 8, 2018 |
| Jan 3, 2018 | 35297496K | RESOLVE | CLASS - 1 | UNAPPROVED,UNSAFE,UNSUITABLE ELECTRICAL EQUIPMENT,APPARATUS,MATERIALS,DEVICES,APPLIANCES, OR WIRING IN USE. OBSERVED ... | $1,600 | $0 | Aug 7, 2018 |
| Oct 3, 2017 | 38258407R | RESOLVE | CLASS - 2 | CU 5X10 5X10 DOOR RESTRICTOR INOPERATIVE,MUST REPAIR.THIS DEVICE IS TOENSURE THE SAFETY OF THE PASSENGERS.NOTIFY DOB ... | $250 | $0 | Feb 6, 2018 |
| Feb 16, 2017 | 38253258J | RESOLVE | CLASS - 2 | 2X10,100N1,70O2,8F1 2X10-PHONE INOPERATIVE; 100N1-ZONE LOCK BYPASSED 70O2-DIRTY PIT; 9F1-CAR KEEPS RELEVELING AT FLOORS. | $0 | $0 | Apr 4, 2017 |
| Jan 25, 2017 | 35225873Y | RESOLVE | CLASS - 3 | WORK W/O PERMIT. OBSERVED ON 01/25/17 AT ABOVE ADDRESS REPLACEMENT.OF A HOT WATER TANK W/O A EWN OR A PERMIT ON FILEA... | $0 | $0 | May 16, 2017 |
| Mar 7, 2016 | 38241575P | RESOLVE | CLASS - 2 | 17H11- REPLACE WORN HOISTWAY DOOR GIBS | $250 | $0 | Apr 26, 2016 |
| Aug 24, 2015 | 35135606K | RESOLVE | CLASS - 3 | WORK DOES NOT CONFORM TO APPROVED CONST DOCUMENTS OR AMENDMENTS.JOB # 40005 6050. NOTED:HOTEL PARTIALLY INSPECTION 1S... | $100 | $0 | Oct 13, 2015 |
| May 14, 2014 | 34882774M | RESOLVE | CLASS - 3 | FAILURE TO MAINTAIN BLDG IN CODE COMOPLIANT MANNER.DEFECT IS 1,2ND,34D FLRS CORRIDOR SPRINKLER HEADS OBSTRUCTED, INSI... | $200 | $0 | Jul 1, 2014 |
| May 14, 2014 | 34882773K | RESOLVE | CLASS - 3 | WORK DOES NOT CONFORM TO APPROVED CONST.DOC.OR AMENDMENTS. JOB #400055890/A3/DNG DATED.02/06/10.NOTED 1-3RD FLR( )#35... | $200 | $0 | Jul 1, 2014 |
| Nov 2, 1998 | 38081302J | RESOLVE | Non-Hazardous | 57O,43U. PERFORM PRESURE RELEIF TEST. | $180 | $0 | Jan 19, 1999 |
| Jan 24, 1996 | 38053046L | RESOLVE | Non-Hazardous | 35B,57Y,57Y,50Y,50Y,54T,14M.35-REPAIR MAIN MACHINE PUMP UNIT INCLOSER 50-REPAIR OIL LEAK TO MAIN MACHINE AND PIT JACK... | $0 | $0 | Mar 12, 1996 |
| Feb 27, 1995 | 38047158P | RESOLVE | Non-Hazardous | 17M, 74L. 17-CAR DOOR VISION GUARD. 74-WHEN PHASE I OF LL5 IS INITIATED THERE IS NO AUDIBLE SIGNAL IN CAR. | $200 | $0 | Apr 11, 1995 |
| Jan 14, 1991 | 34044694J | RESOLVE | Hazardous | FAILURE TO HAVE APPROVED PA PLANS AVAILABLE FOR INSPECTION. REMEDY - OBTAIN & PROVIDE APPROVED PA PLANS | $250 | $0 | Feb 26, 1991 |
| Jan 14, 1991 | 34044695L | RESOLVE | Hazardous | FAILURE TO HAVE, APPROVED PA PLANS AVAILABLE FOR INSPECTION. REMEDY - OBTAIN & PROVIDE APPROVED PA PLANS. | $250 | $0 | Apr 30, 1991 |
| Sep 28, 1989 | 34031721N | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT WORK NOTED EXTENDED PARKING LOT AT REAR OF PREMISES EAST OF 94 ST AND 23 AVE APPROX 10'X 100 AN... | $0 | $0 | Dec 12, 1989 |