35-29-35-61 74 Street, Queens • Block 01274 • Lot 0020
31 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Feb 17, 2021 | 39036366M | ACTIVE | CLASS - 1 | MAIN DRIVE ON BOARD INOPERATIVE REPAIR AND RETURN TO SERVICE ALARM SYSTEM AND EMERGENCY LIGHTS DO NOT WORK WHEN A.C S... | $1,250 | $1,250 | Oct 12, 2021 |
| Mar 17, 2016 | 35177275K | RESOLVE | CLASS - 3 | WORK W/O A PERMIT. NOTE: AT TIME OF INSPECTION OBSERVED WALL ERECTED FULL HEIGHT TO CEILING W/2 DOORS. WALL APPROX 12... | $0 | $0 | May 3, 2016 |
| Jun 26, 2015 | 38237627X | RESOLVE | CLASS - 2 | 05X10,21B01. 05X10-REPAIR DOOR ZONE LOCK; 21R01-PULLING 6TH FLR DOOR CAUSE ELEVATOR STOPS IN FLIGHT. | $500 | $0 | Oct 27, 2015 |
| Apr 17, 2015 | 35095541P | RESOLVE | CLASS - 2 | REMOVAL OF SAFETY MEASURES W/O DEPT APPROVAL.NOTED:@ THE TIME OF THIS VIO'S WRITING,THE FACADE WAS DESIGNATED AS "UNS... | $4,000 | $0 | Jun 2, 2015 |
| May 31, 2013 | 38227421L | RESOLVE | CLASS - 2 | 05X10 - REPAIR DOOR ZONE LOCK. | $0 | $0 | Jul 16, 2013 |
| May 31, 2013 | 38227602K | RESOLVE | CLASS - 2 | 05X10 - REPAIR DOOR ZONE LOCK.RESPONDENT FAILED TO COMPLY W/COMMISSIONERS ORDER TO CORRECT THE VIOLATING CONDITION AN... | $0 | $0 | Nov 12, 2013 |
| May 31, 2013 | 38227601Z | RESOLVE | CLASS - 1 | 05X10 - REPAIR DOOR ZONE LOCK. RESPONDENT FILED A CERTIFICATE OF CORRECTION ON FEB 06,2013 FOR NOV#38225031R UPON INS... | $0 | $0 | Nov 12, 2013 |
| May 31, 2013 | 38227614H | RESOLVE | CLASS - 1 | 05X10 - REPAIR DOOR ZONE LOCK,LICENSED AGENCY,LICENS #346001 SUBMITTEDA NOTARIZED STATEMENT TO BE USED FOR THE DISMIS... | $0 | $0 | Nov 12, 2013 |
| Dec 28, 2012 | 38225035Y | RESOLVE | CLASS - 1 | 05X10- DOOR ZONE LOCK INOPERATIVE. DUNWELL ELEVATOR ELECTRIC IND. LIC #346001 SUBMITTED A TEST REPORT {ELV 3} FOR EBN... | $0 | $0 | May 7, 2013 |
| Dec 28, 2012 | 38225031R | RESOLVE | CLASS - 2 | 05X10,70O02. 05X10-REPAIR DOOR SOME RESTRICTOR DEVICE. | $0 | $0 | Feb 12, 2013 |
| Dec 8, 2012 | 35000384X | RESOLVE | CLASS - 2 | SIDEWALK SHED DOES NOT CONFORM TO CODE SPECIFICATIONS. NOTED: SIDEWALKSHED #42054743-01-EQ-SH DOES NOT EXTEND TO PROT... | $0 | $0 | Jan 22, 2013 |
| Jul 25, 2012 | 34944598N | RESOLVE | CLASS - 1 | NO NOTIFICATION TO DOB PRIOR TO USE/INSTALLATION OF OUTRIGGER BEAMS IN CONNECTION W/ SUSPENDED SCAFFOLDS.NOTED:@ TIME... | $0 | $0 | Nov 27, 2012 |
| Jul 25, 2012 | 34944599P | RESOLVE | CLASS - 2 | 3307.6.4)FAILURE TO PROVIDE ADEQUATE PROTECTION FOR SIDEWALK AND ENTRANCE.NOTED:@ TIME OF INSPEC SUSPENDED SCAFFOLD W... | $800 | $0 | Nov 27, 2012 |
| Dec 6, 2007 | 38180416L | RESOLVE | Non-Hazardous | 51B14,05I11,64X10,86U15. 05I-CAR DOOR VISION GLASS. | $0 | $0 | Jan 29, 2008 |
| Nov 20, 2001 | 34311392H | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN ON 3RD FL APT. WATER LEAK FROM UPSTAIR CEILING SHEET ROCK LOOSE AND SEPARATION FROM JOINTS IN BAT... | $2,500 | $0 | Jan 8, 2002 |
| Mar 17, 2001 | 38114584P | RESOLVE | Non-Hazardous | 47#02,25F11,31D06,31Q03,14B07,55X11,74X11,52#02. 47#02 CLEAN OILY GEVENOR CALBLE SO PROPER INSPECTION CABLE MADE 25-F... | $180 | $0 | May 2, 2001 |
| Mar 17, 2001 | 38114585R | RESOLVE | Non-Hazardous | 55X11,31Q03,50Y11,52#02. TT-X-11 REPAIR PIT LIGHT.31-Q-03 SECOND MISSING COVER ELECTRICAL BOX IN THE SHAFT.50-Y-11 CL... | $180 | $0 | May 2, 2001 |
| Mar 17, 2001 | 38114583N | RESOLVE | Non-Hazardous | 54I11,31Q06,31D06,55X11,52#02. 54-I-11 MAIN LINE DISCONNECTION SWITCH DAMAGED.INOPERATION REPAIR.31-Q-06 PROVIDE COVE... | $180 | $0 | May 2, 2001 |
| May 5, 1999 | 34176818R | RESOLVE | Non-Hazardous | FAILURE TO FILE A REPORT OF COMPLIANCE WITH LOCAL LAW 16/84 CERIFYING TO THE INSTALLATION OF REQUIRED FIRE PROTECTION... | $200 | $0 | Sep 8, 1999 |
| Mar 9, 1998 | 38071121L | RESOLVE | Non-Hazardous | 08V57O58O59O53B36D | $180 | $0 | Apr 29, 1998 |
| Mar 9, 1998 | 38071125Z | RESOLVE | Non-Hazardous | 36D53B | $180 | $0 | Apr 29, 1998 |
| Mar 9, 1998 | 38071124R | RESOLVE | Non-Hazardous | 57O58O59O53D36D | $180 | $0 | Apr 29, 1998 |
| Mar 9, 1998 | 38071123P | RESOLVE | Non-Hazardous | 53B36D57O58O59O | $180 | $0 | Apr 29, 1998 |
| Mar 9, 1998 | 38071122N | RESOLVE | Non-Hazardous | 08V585O59O53D36D | $180 | $0 | Apr 29, 1998 |
| Mar 6, 1998 | 38071116R | RESOLVE | Non-Hazardous | 73O35P | $180 | $0 | Apr 29, 1998 |
| Jun 28, 1993 | 38034660H | RESOLVE | Non-Hazardous | 15L 3&5 FLR DOOR CHECK | $0 | $0 | Sep 14, 1993 |
| Jun 28, 1993 | 38034658Z | RESOLVE | Non-Hazardous | 17I, (17) CAR DOOR & 4FLR VISION PANEL | $0 | $0 | Sep 14, 1993 |
| Jun 28, 1993 | 38034659K | RESOLVE | Non-Hazardous | 17I 15L 17 4FLR VISION PANEL 15 BSMT & 4FLR DOOR CHECK | $0 | $0 | Sep 14, 1993 |
| Jun 28, 1993 | 38034657R | RESOLVE | Non-Hazardous | 54I, (54) REPLACE MAIN LINE SWITCH BOX COVER | $0 | $0 | Sep 14, 1993 |
| Mar 19, 1991 | 38007473Z | RESOLVE | Non-Hazardous | 21L,54L, | $150 | $0 | Sep 24, 1991 |
| Mar 19, 1991 | 38007472R | RESOLVE | Non-Hazardous | 21L,46K, | $150 | $0 | Sep 24, 1991 |