Jan 18, 2024 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SAGGING SUBFLOORING WOOD IN THE KITC... B14 Jan 24, 2024
Jan 18, 2024 C FIRST NO ACCESS TO RE- INSPECT VIOLATION HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT B14, 2nd ST... B14 Feb 13, 2024
Jan 18, 2024 B VIOLATION CLOSED § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT ALL WALLS IN THE... B14 Feb 22, 2024
Jan 18, 2024 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE KITCHENETTE... B14 Feb 22, 2024
Dec 29, 2023 C VIOLATION WILL BE REINSPECTED § 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE WATER CLOSET IN THE BATHROOM LOCATED AT APT A15, 1st STORY, 5th AP... A15 Jan 4, 2024
Oct 31, 2023 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN BATHTUB IN THE BATHROOM LOCATED AT APT A16, 1st ... A16 Nov 6, 2023
Oct 31, 2023 C VIOLATION CLOSED § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE APT ENTRANCE DOOR IN THE BATHROOM LOCATED AT APT A1... A16 Nov 6, 2023
Oct 31, 2023 C VIOLATION CLOSED § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOOR IN THE ENTRANCE LOCATED AT APT A16, 1st STORY,... A16 Nov 6, 2023
Oct 31, 2023 C VIOLATION WILL BE REINSPECTED § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASH BASIN WASTE LINE PIPE IN THE BATHROOM LOCAT... A16 Nov 6, 2023
Oct 31, 2023 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... A16 Nov 6, 2023
Oct 23, 2023 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL... B12 Nov 6, 2023
Oct 23, 2023 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL... Nov 6, 2023
Oct 23, 2023 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT B12, 2nd STO... B12 Nov 27, 2023
Oct 23, 2023 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT ALL WALLS IN THE BA... B12 Nov 27, 2023
Oct 23, 2023 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT B12, 2nd STORY... B12 Nov 27, 2023
Oct 23, 2023 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPOUT AT BATHTUB IN THE BATHROOM LOCATED AT APT B12... B12 Nov 27, 2023
Sep 5, 2023 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE THE BROKEN GLASS AT MEDECINE CABINET IN THE BATHROO... A15 Sep 11, 2023
Sep 5, 2023 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... A15 Sep 11, 2023
Sep 1, 2023 A FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2026 ADM CODE REPAIR LEAKY WATER CLOSET FLUSH PIPE CONNECTION IN THE BATHROOM LOCATED AT APT A15, 1st STORY, 8th... A15 Dec 5, 2023
Sep 1, 2023 C VIOLATION CLOSED § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE BATHROOM LOCATED AT... A15 Sep 7, 2023
Sep 1, 2023 C VIOLATION CLOSED § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED WIRES AT ... A15 Sep 7, 2023
Aug 30, 2023 C VIOLATION CLOSED § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WATER CLOSET IN THE BATHROOM LOCATED AT APT A14, 1st STO... A14 Sep 5, 2023
Aug 30, 2023 C VIOLATION CLOSED § 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE WASH BASIN AND VANITY IN THE BATHROOM LOCATED AT APT A14, 1st STOR... A14 Sep 5, 2023
Aug 30, 2023 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE VENTILATION SYSTEM IN THE BATHROOM LOCATED AT APT A... A14 Oct 4, 2023
Aug 30, 2023 C VIOLATION CLOSED § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BASE CABINET COUNTER TOP IN THE KITCHEN LOCATED AT ... A14 Sep 5, 2023
Aug 30, 2023 C VIOLATION CLOSED § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF ELECTRIC FUSE BOX... A14 Sep 5, 2023
Aug 30, 2023 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE VENTILATION SYSTEM IN THE KITCHEN LOCATED AT APT A1... A14 Oct 4, 2023
Aug 30, 2023 C VIOLATION CLOSED § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... A14 Sep 5, 2023
Aug 10, 2023 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILED WEST WALL IN THE BATHR... B14 Aug 16, 2023
Aug 10, 2023 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL... B14 Aug 24, 2023
Aug 10, 2023 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INOPERATIVE DOOR LOCK IN THE ENTRANCE LOCATED AT AP... B14 Aug 16, 2023
Aug 10, 2023 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL TILED WOOD FLOOR IN THE KITCHE... B14 Sep 14, 2023
Aug 10, 2023 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILED SOUTH WET WALL IN THE ... B14 Aug 16, 2023
Aug 9, 2023 B VIOLATION DISMISSED § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT B14, 2nd STORY... B14 Sep 13, 2023
Aug 9, 2023 B VIOLATION DISMISSED § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... B14 Sep 13, 2023
Aug 9, 2023 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE VENTILATION SYSTEM IN THE KITCHENETTE LOCATED AT AP... B14 Sep 13, 2023
Aug 9, 2023 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE VENTILATION SYSTEM IN THE BATHROOM LOCATED AT APT B... B14 Sep 13, 2023
Aug 4, 2023 C VIOLATION CLOSED § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE UPPER SASH WINDOW IN THE ENTIRE APARTMENT LOCATED A... 14A Aug 10, 2023
Aug 4, 2023 C FIRST NO ACCESS TO RE- INSPECT VIOLATION HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 14A, 1st... 14A Aug 30, 2023
Aug 4, 2023 C VIOLATION CLOSED § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN TH... 14A Aug 10, 2023
Aug 4, 2023 C VIOLATION CLOSED § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE BOTTOM OF SO... 14A Aug 10, 2023
Jun 27, 2023 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL... A17 Jul 11, 2023
Jun 27, 2023 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL TILES AT FLOOR IN THE 1st ROOM... A17 Aug 1, 2023
Jun 27, 2023 C VIOLATION CLOSED § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS AT BUILDING ENTRANCE AT PUBLIC HALL, 1st STORY Jul 3, 2023
Jun 27, 2023 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT A7, 1st STORY,... A7 Jul 3, 2023
Jun 27, 2023 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE WASH BASIN AND VANITY AT NORTH WALL IN THE BATHROOM LOCATED AT APT... A7 Jul 3, 2023
Jun 27, 2023 C FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WINDOW GLASS LOWER SASH OFFSET 2 WINDOW AT NORTH WA... A7 Jul 3, 2023
May 17, 2023 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ...MISSING IN THE 1... B14 Jun 21, 2023
May 17, 2023 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR ..MISSING IN THE 1st ROOM FROM NORTH LOCATED AT APT B14, 2nd ... B14 Jun 21, 2023
May 17, 2023 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). ...MISSING IN THE 1st ROOM FROM NORTH LOC... B14 Jun 21, 2023