98-08 Astoria Boulevard, Queens
Queens • Block 01378 • Lot 0028 • Zip: 11369
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 6 days ago- Grand Central 49 min 25 walking, 24 riding
- Times Square 52 min 25 walking, 27 riding
- Penn Station 58 min 25 walking, 33 riding
- Union Square 60 min 25 walking, 35 riding
- Fulton Street 66 min 25 walking, 41 riding
- Downtown Brooklyn 70 min 25 walking, 45 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Railroad
Bus
Citi Bike
Activity
Sales, filings, permits and violations from every dataset, in one order.
2025
-
DOB violation Nov 14, 2025
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
2024
-
DOB violation Sep 23, 2024
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
2023
-
DOB violation Jun 30, 2023
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
-
DOB violation Jun 30, 2023
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
-
DOB violation Jun 20, 2023
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
-
DOB violation Jun 20, 2023
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
2017
-
Alteration Type II
FILING TO REPLACE HVAC UNIT. NEW UNIT ONTO EXISTING DUNNAGE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
2016
2015
-
Alteration Type II
FILING TO REPLACE HVAC UNITS. NEW UNITS ONTO EXISTING DUNNAGE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
2011
-
Alteration Type II
INSTALLATION OF 2-LEVEL LIFT ELEVATOR & SHAFTWAY BETWEEN 1ST & 2ND FLOORS.
2010
-
Alteration Type II
FILING FOR RENOVATION OF MIXED USE BUILDING. FUNERAL ROLE AND RESIDENTIAL APTS.. RELAMINATION OF WALLS, FINISHED FLOO...
-
Alteration Type III
INSTALLATION OF HEAVY DUTY SIDEWALK SHED A TOTAL OF 60 L.F. AS PER PLAN AT 98-08 ASTORIA BLVD. WORK SHALL COMPLY WITH...
2009
-
Alteration Type III
FILING FOR FACADE REPAIR. REPLACEMENT AND RE-POINTING OF BRICK FACADE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
-
CLASS - 2
FAILURE TO PROVIDE ADEQUATE/CORRECT INFORMATION FOR JOB SITE SIGN. JOBSITE SIGN FOR SIDEWALK SHED STATES PERMIT #1104...
-
CLASS - 1
FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES,NOTED: AT FRONT OFBUILDING,(STREETS) CRACKS IN WALL AROUND AC UNI...
2003
-
Non-Hazardous
B4A, 44C, 50, 21A 50 PRESENTROLS MUST BE SEPARATED AND EACH 1 INSTALLED ON A SEPERATE LINE AND PIGTAIL SYPHON
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Building Permits
Owner information from Department of Buildings filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records