ECB violations
34-01 90 Street, Queens • Block 01451 • Lot 0001
82 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jul 2, 2025 | 39152649K | ACTIVE | CLASS - 1 | (05-A-10) CEASE USE ITEM. DOOR ZONE RESTRICTOR HAS BEEN TAMPERED WITH/DISABLED AND RENDERED (MISSING) INOPERATIVE. TH... | $1,250 | $0 | Mar 2, 2026 |
| Mar 7, 2025 | 39140705H | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT TIME OF INSPECTION I OBSERVED 3 GAS DRYERS CONNECTED TO GAS... | $1,250 | $0 | May 13, 2025 |
| Mar 7, 2025 | 39140706J | ACTIVE | CLASS - 2 | WORK WITHOUT PERMIT. AT TIME OF INSPECTION IN BASEMENT I OBSERVED ILLEGAL LAUNDRY ROOM WITH 3 GAS DRYERS AND 3 WASHIN... | $1,250 | $0 | May 13, 2025 |
| Jan 5, 2024 | 39102788P | RESOLVE | CLASS - 1 | DOOR ZONE RESTRICTOR TAMPERED WITH DISABLED. RESTRICTOR PLUNGER WAS REMOVED SITTING ON TOP OF THE MAIN LINE IN THE MA... | $3,125 | $0 | Mar 12, 2024 |
| Oct 11, 2023 | 37025513R | RESOLVE | CLASS - 1 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER IN DOB VIOLATION VIO23-01934, DATED 6/27/2023. RESPONDENT WAS REQUIRE... | $2,500 | $0 | Feb 20, 2024 |
| Aug 6, 2023 | 39091933L | RESOLVE | CLASS - 1 | (05-A-10) CEASE USE ITEM. DOOR ZONE RESTRICTOR HAS BEEN TAMPERED WITH/ DISABLED AND RENDERED INOPERATIVE. THIS IS A S... | $1,250 | $0 | Nov 14, 2023 |
| Jun 27, 2023 | 39089212Z | ACTIVE | CLASS - 2 | NOTED: AT TIME OF INSPECTION, OBSERVED THE GARAGE WITH RUNNING CRACKS ON THE BEAMS/GIRDERS, SLABS AND IN SEVERAL LOCA... | $625 | $0 | Sep 5, 2023 |
| Jun 21, 2023 | 39088815N | RESOLVE | CLASS - 1 | (05-A-10) CEASE USE ITEM. DOOR ZONE RESTRICTOR HAS BEEN TAMPERED WITH/ DISABLED AND RENDERED INOPERATIVE. THIS IS A S... | $1,250 | $0 | Aug 29, 2023 |
| Mar 6, 2023 | 39080758J | ACTIVE | CLASS - 1 | CEASED USE BOILER,ROCKMILLS 125 WATER LEAKING FROM CHAMBER,MISSING BOLTS& DOGS ON BOILER DOORS,SUPPLY PUMP NEEDS TO B... | $1,250 | $0 | May 16, 2023 |
| Feb 10, 2023 | 39079519Y | RESOLVE | CLASS - 1 | DLM INOPERATIVE , REPAIR / ZONE LOCK MADE INOPERATIVE , REPAIR / IN CAR EMERGENCY OUTSIDE COMM INOPERATIVE , TRPAIR /... | $1,250 | $0 | Sep 12, 2023 |
| Oct 14, 2022 | 39071967L | RESOLVE | CLASS - 1 | DLM IMPROPERLY INSTALLED ON THIS DEVICE . NO FIREMAN'S SERVICE PRESENT IN CONTROLLER . INSTALL FIREMAN'S SERVICE SO D... | $625 | $0 | Apr 18, 2023 |
| Sep 13, 2022 | 39069977M | ACTIVE | CLASS - 1 | DOOR ZONE RESTRICTOR NOT WORKING TAMPERED WITH DISABLED(CU). DLM WAS INSTALLED AS MANDATED BY CODE 3.10.12 APPENDIX K... | $3,125 | $0 | Dec 6, 2022 |
| Jul 22, 2022 | 39066479X | ACTIVE | CLASS - 1 | CEASE USE ITEMS : ZONE LOCK , A SAFETY DEVICE , HAS BEEN DISABLED , REPAIR / FUSES ON CONTROLLER JUMPED OUT , REPAIR ... | $1,250 | $0 | Sep 6, 2022 |
| Apr 25, 2022 | 39060990X | ACTIVE | CLASS - 1 | CEASE USE ITEM : CAR STOPS NOT LEVEL BY 4" , REPAIR / NON CEASE USE ITEMS : DLM IMPROPERLY INSTALLED ON THIS DEVICE .... | $12,500 | $0 | Jun 14, 2022 |
| Dec 15, 2021 | 39052915X | ACTIVE | CLASS - 1 | CEASE USE ITEMS : ZONE LOCK , A SAFETY DEVICE , HAS BEEM BYPASSED , REPAIR / DOOR LOCK MONITOR , A SAFETY DEVICE IS I... | $6,250 | $0 | Feb 1, 2022 |
| Jul 30, 2020 | 39026170L | RESOLVE | CLASS - 1 | 1. PROVIDE BRAKE MAINTENANCE . 2. NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPE... | $3,125 | $0 | Sep 15, 2020 |
| Jun 29, 2020 | 37019416Y | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #35210484Z ON 2/23/17,AND TO FILE A CERTIF... | $3,125 | $0 | Oct 20, 2020 |
| Jun 29, 2020 | 37019434H | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #35133978M ISSUED ON 1/14/16,AND TO FILE A... | $3,125 | $0 | Oct 20, 2020 |
| Jul 24, 2019 | 38270249M | RESOLVE | CLASS - 1 | CU7N11,61R9,2X10,98B7,100M7. 7N11-ZONE LOCK HAS BEEN BYPASSED TO ALLOWCAR DOOR TO BE OPENED WHEN OUT OF DOOR ZONE CAU... | $1,280 | $0 | Oct 29, 2019 |
| Apr 24, 2019 | 38269339H | RESOLVE | CLASS - 1 | CEASE USE. 7A11, 21L10, 2X10, 70O2, 98D7 7A11-ZONE LOCK PLUNGER REMOVED ALLOWING CAR DOOR TO BE WORN OUT OF ZONE CAUS... | $1,250 | $0 | Oct 22, 2019 |
| Nov 20, 2018 | 37012399J | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION#32092998M ISSUED ON 02/07/18,AND TO FILE A ... | $1,250 | $0 | Apr 9, 2019 |
| Jul 9, 2018 | 38262436H | RESOLVE | CLASS - 1 | CU05A01; CU08V01. 05A01=DOOR RESTRICTOR ALTERED; CU08V01-DEVICE STOP PED 2'ABOVE 1ST FLOOR W/INSPECTOR INSIDE AND DOO... | $3,125 | $0 | Oct 9, 2018 |
| Feb 13, 2018 | 38260566R | RESOLVE | CLASS - 1 | C/U 59L10. 59L10 DEVICE SLIPS THRU BRAKES.CEASE USE.CALL DOB FOR REINSPECTION.BRING FULL LOAD CAPACITY. | $1,000 | $0 | May 1, 2018 |
| Feb 8, 2018 | 35265353R | RESOLVE | CLASS - 2 | REMOVAL OF SAFETY MEASURE, SUCH AS SIDEWALK SHEDS W/O DEPT APPROVAL. AT THE TIME OF INSPECTION BUILDING FACADE WAS ST... | $800 | $0 | Feb 12, 2019 |
| Feb 7, 2018 | 32092998M | ACTIVE | CLASS - 2 | B254;5B;15;16;48A;50A:PIGTAILS ON CONTROLS AND STEAM GAUGE WRONG MATERIAL.CORRECT ALL VIOLATING CONDITIONS AND SUBMIT... | $500 | $0 | Mar 27, 2018 |
| Oct 31, 2017 | 38258885L | RESOLVE | CLASS - 2 | 8V1,56Y13,56Q3,70O2. 8V1,56Y13,56Q13,70O2. | $0 | $0 | Dec 19, 2017 |
| Oct 31, 2017 | 38258884J | RESOLVE | CLASS - 2 | 8V1,100D6,67X10,56Y13,5J1. 8V1,100D6 HANDRAIL UNSECURE PROPERLY SECURE67X10,56Y13,5J1. | $0 | $0 | Dec 19, 2017 |
| Feb 23, 2017 | 35210486M | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES.NOTE:NORTH ELE,EXPO#1,DAMAGE/SPALLING BRICKS AT 3RD FL... | $250 | $0 | Apr 11, 2017 |
| Feb 23, 2017 | 35210484Z | RESOLVE | CLASS - 1 | FAILURE TO TAKE PROVIDE SAFETY MEASURE SIDEWALK SHEDS,NETTING,ETC,WHERE REQUIRE TO PROTECT AND SECURE PUBLIC SAFETY F... | $2,400 | $0 | Apr 11, 2017 |
| Feb 23, 2017 | 35210485K | RESOLVE | CLASS - 2 | REMOVAL OF SIDEWALK SHEDS WITHOUT DEPARTMENT APPROVAL.NOTE:AT THE TIMEOF INSPECTION BUILDING FACADE WAS STILL DESIGNA... | $400 | $0 | Apr 11, 2017 |
| Nov 7, 2016 | 37001669R | RESOLVE | CLASS - 2 | FAILURE TO FILE ACCEPTABLE AMENDED REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW 1... | $830 | $0 | Jun 6, 2017 |
| Jan 14, 2016 | 35133977K | RESOLVE | CLASS - 1 | FAIL TO TAKE AND PROVIDE SAFETY MEASURE/SIDEWALK SHED,NETTING,ETC. WHERE REQ.NOTE:FACADE TECH RPT FILE UNSAFE BY PE/R... | $12,000 | $0 | Mar 1, 2016 |
| Jan 14, 2016 | 35133978M | RESOLVE | CLASS - 1 | FAIL TO MAINTAIN EXTERIOR BLDG.NOTE:NORTH ELEV, EXP #1 OBS SPALL/BROKEN WINDOW SILLS @VAR LOCS & FLRS,ALSO CRACK/BULD... | $1,030 | $0 | May 3, 2016 |
| Nov 7, 2015 | 38239306Y | RESOLVE | CLASS - 2 | 05J01,34O02,14T11,70O02,08V01,56Y02,56Y13,16J01,16T10. 05J01-ADJUST GAP BETWEEN CAR DOOR AND RETURN POST; 16J01-ADJUS... | $0 | $0 | Dec 22, 2015 |
| Nov 7, 2015 | 38239305M | RESOLVE | CLASS - 2 | 08V01,67X10,56Y02,56Y13,57BB11,21J01. 21J01-CAR DOOR HESITATES TO RE OPEN WHEN PUSHED ON HATCH DOOR FROM INSIDE THE E... | $0 | $0 | Dec 22, 2015 |
| Jun 26, 2015 | 38237626Y | RESOLVE | CLASS - 2 | 67X10,71X10,70O02. 6X10-REPAIR EMERGENCY PHONE; 71X10-REPAIR PIT LIGHT70002-CLEAN PIT. | $2,500 | $0 | Aug 11, 2015 |
| Jun 26, 2015 | 38237625M | RESOLVE | CLASS - 2 | 69X10,14I11,15I11,73O02,74O02,70O02. 67X10-REPAIR EMERGENCY PHONE; 14I11-REPALCE DAMAGED CAR MIRROR; 15I11-REPLACE DA... | $2,500 | $0 | Aug 10, 2015 |
| Jun 9, 2015 | 35133208X | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BLDG(NORTH ELEV.)EXP.1 SCREENS NOTE SECURED F/4,5 MISSING LOUVER PARAPET,CAMEL BRICKS CR... | $500 | $0 | Oct 27, 2015 |
| Jan 26, 2015 | 36027239X | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE CYCLE 7 TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXT... | $4,000 | $0 | Jul 14, 2015 |
| Jan 22, 2015 | 35119222L | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN NOTE AT EAST FACADE 2 A/C UNITS IN WINDOWS W/O ADEQUATE SUPPORT BRACKETS 1 ON FLR 5 AND 1 ON FLR ... | $5,000 | $0 | Mar 24, 2015 |
| Dec 13, 2014 | 35041602X | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/ THE COMM'S ORDER TO FILE A CERT OF CORRECTION W/ THE DEPT OF BLDG FOR NOTICE OF VIOLATION #35101... | $800 | $0 | May 26, 2015 |
| Nov 23, 2014 | 38233680R | RESOLVE | CLASS - 2 | 14L11,67L10,100Q07,40O02,68B07,41M07. 14-REPLACE MIRROR IN CAB; 67-REPAIR PHONE IN CAB; 100-PROVIDE GUARD FOR FAN IN ... | $2,500 | $0 | Jan 13, 2015 |
| Oct 24, 2014 | 35101269N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN: SEVERAL WINDOW AC UNITS DO NOT HAVE REQUIRED SUPPORT BRACKETS. ON FRONT FACADE FLOORS 2,5,6. REM... | $10,000 | $0 | May 5, 2015 |
| Aug 7, 2014 | 35025861K | RESOLVE | CLASS - 1 | FAIL TO MAINTAIN BLDG WALLS OR APPURTENANCES.NOTED @ EXPO 1,2,3 & 4 ASHIGH AS 7TH FL LVL THERE ARE WINDOW A/C OR UNIT... | $5,000 | $0 | Sep 23, 2014 |
| Apr 23, 2014 | 35091444P | RESOLVE | CLASS - 3 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.DEFECT NOTED:@ ALL EXPOSURES SOME WINDOW AIR CONDITIONER UNITS ARE ... | $230 | $0 | Jun 10, 2014 |
| Mar 17, 2014 | 35024222J | RESOLVE | CLASS - 2 | FAIL TO MAINTAIN EXTERIOR BLDG.NORTH ELEVATION,EXP #1 OBS CRACKS,DISPLACEMENT & DETERIORATING IN PARAPET FACADE.BROKE... | $530 | $0 | Jun 10, 2014 |
| Jul 1, 2013 | 35022126K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG. NOTED: OBSERVED WINDOW A/C UNITS INSTALLED THROUGHOUT BLDG W/O STEEL BRACKETS. REMEDY: INST... | $530 | $0 | Oct 15, 2013 |
| May 15, 2013 | 35019782L | RESOLVE | CLASS - 3 | WORK W/O A PERMIT: AT APT #5D ERECTED FULL HEIGHT PARTIITONS CREATING 2 BEDROOMS (ADDITIONAL) AT DINING ROOM/LIVING R... | $200 | $0 | Jul 2, 2013 |
| May 15, 2013 | 35019783N | RESOLVE | CLASS - 3 | WORK W/O A PERMIT: NOTED: AT APT #5C ERECT FULL HEIGHT PARTITION AT DINING ROOM CREATE ADDITIONAL BEDROOM,NO JOB FILI... | $200 | $0 | Jul 2, 2013 |
| Jun 29, 2012 | 36018511L | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCEW/ARTICLE 28-302 OF THE BLDG CODE AND DOB'S RUL... | $4,000 | $0 | Nov 27, 2012 |