ECB violations

86-15-86-29 37 Avenue, Queens • Block 01460 • Lot 0034

31 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Mar 26, 2026 35727325N ACTIVE CLASS - 2 REISSUE #35717384Y DATE OF ISSUE: 04/28/2025. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. CRACKS IN MAIN E... $3,125 $0 May 15, 2026
Mar 26, 2026 35727349H ACTIVE CLASS - 2 EXIT DOOR NOT SELF-CLOSING PROPERLY. AT THE TIME OF INSPECTION, OBSERVED AND NOTED AT 1ST FLOOR EXIT-2 AND EXIT-3 DOO... $625 $0 May 15, 2026
Mar 26, 2026 35727326P ACTIVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS P... $1,250 $0 May 15, 2026
Apr 28, 2025 35717384Y ACTIVE CLASS - 2 REISSUE #35678871M. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. CRACKS IN MAIN ENTRY DOORWAY. BASE OF DOOR... $3,125 $0 May 27, 2025
May 7, 2024 35678871M ACTIVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.CRACKS IN MATH DOOR WAY BASE OF DOOR FRAME RUSTING AND BASE OF ... $625 $0 Jul 16, 2024
Apr 26, 2017 35253380Y RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER USE OF PROHIBITED DOOR HARDWARE PER BC 1008-1.8;27-37. ILLEGAL KICK... $0 $0 Sep 5, 2017
Apr 8, 2015 35128137L RESOLVE CLASS - 2 REISSUED VIOLATION #35027838L FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTED: WATER PENETRATION BLDG EN... $0 $0 Jun 16, 2015
Sep 5, 2014 35107490J RESOLVE CLASS - 2 REISSUE 35027837J.NO ILLUMINATED EXIT SIGNAGE PROVIDED @ BOILER ROOM.REM:PROVIDE SIGNAGE. $0 $0 Oct 28, 2014
Sep 5, 2014 35107489M RESOLVE CLASS - 2 REISSUE 35027838L.WATER PENETRATION THROUGHT ROOF &/OR FACADE HALLWAY CEILING OUTSIDE RM 402 & @ EXIT 2 CORRIDOR 1FL.... $0 $0 Oct 28, 2014
Jul 16, 2013 35027839N RESOLVE CLASS - 2 CELLAR -GAS METER ROOM AREAWAY EXTERIOR SIDE OF GAS METER ROOM - STORAGE OF PLANS, 5 GALLON PLASTIC CONTAINERS, MISC ... $0 $0 Sep 17, 2013
Jul 16, 2013 35027838L RESOLVE CLASS - 2 REISSUE 34901909L EXTERIOR ROOF AND BRICK FACADE HAS BECOME POROUS & ALLOWS RAIN WATER INTO BUILDING CAUSING INTERIOR... $0 $0 Sep 17, 2013
Jul 16, 2013 35027837J RESOLVE CLASS - 2 REISSUE 34949619X MISSING EXIT SIGNS - BOILER ROOM CELLAR MISSING EXIT SIGNS NO ILLUMINATED EXIT SIGNS OR ANY EXIT SI... $0 $0 Sep 17, 2013
Mar 27, 2012 34949618Y RESOLVE CLASS - 2 PARTIAL CORRIDOR OBSTRUCTION AT 1ST FLOOR PARTIAL OBSTRUCTION W/ BOOK CASES TABLES BOXES AND ROLLING CARTS REM: REMOV... $0 $0 Jun 5, 2012
Mar 27, 2012 34949619X RESOLVE CLASS - 2 MISSING EXIT SIGNS. AT BOILER ROOM NO ILLUMINATED EXIT SIGNS OR ANY EXIT SIGNS. REM:PROVIDE EXIT SIGNS. $0 $0 Jun 19, 2012
Mar 3, 2011 34901909L RESOLVE CLASS - 2 REISSUE: 34848012R, 34848011P. EXTERIOR ROOF AND BRICK FACADE HAS BECOME POROUS AND ALLOWING RAIN WATER INTO THE BLDG... $0 $0 May 3, 2011
May 14, 2010 34848013Z RESOLVE CLASS - 2 SEC. 28-301.1 FAILURE TO MAINTAIN EGRESS CLEAR & UNOBSTRUCTED OBSERVED: 2ND FL MAIN CORRIDOR PARTIALLY OBSTRUCTED BY ... $0 $0 Sep 14, 2010
May 14, 2010 34848012R RESOLVE CLASS - 2 FAILURE TO MAINTAIN OBSERVED WATER PENETRATION FROM ROOF INTO RMS 406,407,MAIN CORRIDOR 4FL. REMEDY: MAINTAIN BUILDING. $0 $0 Sep 14, 2010
May 14, 2010 34848011P RESOLVE CLASS - 2 REISSUE 34761944P FAILURE TO MAINTAIN OBSERVED WATER PENETRATION THROUGH FACADE EXIT 2,FL 1. REMEDY: MAINTAIN BUILDING. $0 $0 Sep 14, 2010
Mar 20, 2009 34761943N RESOLVE CLASS - 2 BULKHEAD DOOR LEADING TO ROOF IS DEFECTIVE. DOOR LOCK IS NOT PROPERLY INSTALLED. REMEDY: REPAIR/REPLACE. $0 $0 May 12, 2009
Mar 20, 2009 34761944P RESOLVE CLASS - 2 EXTERIOR BRICK FACADE HAS BECOME POROUS AND ALLOWING RAIN INTO THE BLDG BY EXIT 2 (1ST FLR) CAUSING INTERIOR DAMAGES.... $0 $0 May 12, 2009
Mar 20, 2009 34761945R RESOLVE CLASS - 2 THE ELECTRICAL ROOM (C03) AT CELLAR LEVEL IS BEING USED AS STORAGE ROOM CONSISTING OF COMPUTERS AND DECK. REMEDY: REM... $0 $0 May 12, 2009
Aug 28, 2007 34592905H RESOLVE Non-Hazardous REISSUE #34526990X.CORRIDOR SMOKE STOP DOOR NOT SELF CLOSING.NOTED:CELLAR MANUAL OPERATED 2 DOORS ADJ TO ROOM CJSC HA... $0 $0 Nov 13, 2007
Aug 28, 2007 34592906J RESOLVE Non-Hazardous REISSUE #34526991H.1FL CAFETERIA/MULTI PURPOSE RM 2 EXIT DOORS WHEN CLOSED ARE SAGGING & HITTING EACH OTHER.REMEDY:RE... $0 $0 Nov 13, 2007
Aug 28, 2007 34592907L RESOLVE Non-Hazardous WATER PENETRATION THROUGH CEILING INTO CORRIDOR IN FRONT OF ROOM 407 &INTO CLASSROOM #406.REMEDY:STOP WATER PENETRATI... $0 $0 Nov 13, 2007
Jun 2, 2006 34526991H RESOLVE Non-Hazardous REISSUED ECB# 34474490H. 1ST FL CAFETERIA/MULIT PURPOSE RM 2 EXIT DOORS WHEN CLOSED ARE SAGGING AND HITTING EACH OTHE... $0 $0 Aug 15, 2006
Jun 2, 2006 34526990X RESOLVE Non-Hazardous CORRIDOR SMOKE STOP DOORS NOT SELF CLOSING. NOTED:CELLAR MANUAL OPERATED 2 DOORS ADJ TO RM CJSA HAS NO CHECKS. REISSU... $0 $0 Aug 15, 2006
Mar 25, 2005 34474488Z RESOLVE Non-Hazardous EXIT PASSAGEWAY OR CORRIDOR REQUIRED WIDTH DECRESED BY OBSTRUCTION NOTED FOURTH FLOOR CORRIDOR BLOCKED AT 12 ELECTRIC... $0 $0 Aug 2, 2005
Mar 25, 2005 34474490H RESOLVE Non-Hazardous FAILURE TO MAINTAIN BUILDING DEFECT NOTED FIRST FLOOR CAFETERIA MULTI PURPOSE ROOM 2 EXIT DOORS WHEN CLOSED SAGGING A... $0 $0 Aug 2, 2005
Mar 25, 2005 34474489K RESOLVE Non-Hazardous CORRIDOR SMOKE STOP DOORS NOT SELF-CLOSING NOTED CELLAR MANUAL OPERATED 2 DOORS NEAR ROOM C-JSC HAVE NO CHECKS REMEDY... $0 $0 Aug 2, 2005
Jan 6, 2003 34376175Z RESOLVE Hazardous FAILURE TO MAINTAIN BUILDING. DEFECT: MISSING FIREPROOFING MATERIAL ONCEILING (METAL DECKING) BETWEEN CELLAR & FIRST ... $0 $0 Mar 18, 2003
Jan 6, 2003 34376174R RESOLVE Hazardous FAILURE TO MAINTAIN BUILDING. DEFECT: MISSING FIREPROOFING MATERIAL UNDER METAL DECKING (ROOF SLAB) IN PENTHOUSE -MAC... $0 $0 Mar 18, 2003