| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jul 19, 2021 | 35583452X | RESOLVE | CLASS - 2 | JOBSITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBSECTION.AT THE TIME OF INSPECTION,THIS WAS A 4 STORY BUILD... | $1,030 | $0 | Oct 12, 2021 |
| Sep 30, 2020 | 35503691K | RESOLVE | CLASS - 2 | BC 3301.13.12 CONSTRUCTION SUPERINTENDENT FAILED TO DESIGNATE A COMPETENT PERSON AND ENSURE SUCH PERSON IS PRESENT AT... | $1,250 | $0 | Dec 22, 2020 |
| Sep 30, 2020 | 35503692M | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS.AT THE TIME OF MY INSPECTION OF AN ACTIVE NB PROJE... | $1,250 | $0 | Dec 22, 2020 |
| Sep 30, 2020 | 35503693Y | RESOLVE | CLASS - 2 | BC 3303.7.2 FIRE EXTINGUISHERS SHALL BE PROVIDED IN ACCORDANCE WITH NEW YORK CITY FIRE CODE.AT THE TIME OF MY INSPECT... | $1,250 | $0 | Dec 22, 2020 |
| Aug 5, 2020 | 35492502L | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION,OBSERVED ONGOING CONSTRUCTION ACTIVITIES CONTRARY TO MAYOR'S EMERGENCY EXECUTIVE ORDER 120 & SU... | $5,000 | $0 | Feb 9, 2021 |
| Mar 10, 2020 | 35469176J | RESOLVE | CLASS - 1 | CONTRACTOR FAILED TO ENSURE THAT EACH CONSTRUCTION OR DEMOLITION WORKER WORKING/ENGAGED AT THE SITE SUCCESSFULLY COMP... | $0 | $0 | Dec 15, 2020 |
| Feb 10, 2020 | 35470940Y | RESOLVE | CLASS - 1 | BC3314.4.8 SCAFFOLD MAINTENANCE.AT TIME OF INSPECTION OF AN ACTIVE JOBSITE I OBSERVED A SUPPORTED SCAFFOLD INSTALLED ... | $2,500 | $0 | Jul 14, 2020 |
| Feb 10, 2020 | 35470938P | RESOLVE | CLASS - 1 | COMPETENT PERSON.AT TIME OF INSPECTION OF AN ACTIVE JOBSITE W/APPROX 8 WORKERS ON SITE,I REQUESTED FROM SEVERAL WORKE... | $10,000 | $0 | Nov 10, 2020 |
| Feb 10, 2020 | 35470939R | RESOLVE | CLASS - 1 | BC3301.6 DESIGN DRAWINGS.AT THE TIME OF INSPECTION I OBSERVED A MAKE SHIFT PULLY SYSTEM AT THE FOURTH FLOOR TERRACE,T... | $2,500 | $0 | Jul 14, 2020 |
| Dec 6, 2019 | 35456228J | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION-SIDEWALK SHED LIGHT. NOTE: AT TIME OF MY INSPECTION OF A 4 STY... | $5,000 | $0 | Feb 18, 2020 |
| Jul 24, 2019 | 35438601J | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION OES NOT MEET CODE SPECIFICATION #3307.6.4.8: NOTE AT THE TIME OF MY INSPECTION I OBSERVED A SID... | $2,400 | $0 | Jan 28, 2020 |
| Jul 17, 2019 | 35420367P | RESOLVE | CLASS - 2 | BC3301.2 FAILURE TO SAFEGUARD (NO OVERHEAD PROTECTION) AT TIME OF INSPECTION, I OBSERVED NB FRAMING STRUCTURES AT ROO... | $625 | $0 | Sep 24, 2019 |
| Jul 17, 2019 | 35420369Z | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED/ACCEPTED CONSTRUCTION DOCUMETNS AT JOBSITEAT TIME OF INSPECTION (NO SOE PLANS FOR RETAINI... | $0 | $0 | Sep 24, 2019 |
| Jul 17, 2019 | 35420368R | RESOLVE | CLASS - 2 | BC3309.10 FAILURE TO PROTECT ADJOINING PROPERTIES (MISSING ROOF PRO TECTION). AT TIME OF INSPECTION I OBSERVED NB 4 S... | $625 | $0 | Sep 24, 2019 |
| Apr 19, 2019 | 35384792K | RESOLVE | CLASS - 2 | FENCE MAINTENANCE/EXPIRED FENCE PERMIT. AT TIME OF INSPECTION I OBSERVED THE JOBSITE FENCE CAVING INWARD AND NOT PLUM... | $0 | $0 | Jun 25, 2019 |
| Mar 26, 2019 | 35412094Z | RESOLVE | CLASS - 1 | BC3301.13.1.SITE SAFETY PLAN.AT TIME OF INSPECTION ON A PROPOSED 4 STORY BLDG AT FOUNDATION PHASE REQUESTED TO VIEW S... | $2,500 | $0 | Sep 12, 2019 |
| Mar 26, 2019 | 35412095K | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND OR AMENDMENTS.AT TIME OF INSPECTION ON A PROPOSED 4-STOR... | $0 | $0 | Jun 4, 2019 |
| Mar 11, 2019 | 35411803H | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN SAFETY OPERATION-INADEQUATE GUARDRAILS. OBSERVED AT TIME OF INSPECTION W/ GC AND SUBCONTRACTOR ON... | $2,500 | $0 | May 28, 2019 |
| Mar 11, 2019 | 35411805L | RESOLVE | CLASS - 2 | FENCE NOT CONSTRUCTED TO CODE. AT TIME OF INSPECTION W/ GC AND SUBCONTRACTOR ON SITE,OBSERVED CONSTRUCTION FENCE OUT ... | $400 | $0 | May 28, 2019 |
| Mar 11, 2019 | 35411804J | RESOLVE | CLASS - 2 | 3304.7 REQUIRED MEANS OF EGRESS-MISSING/INADEQUATE EGRESS. AT TIME OF INSPECTION ON SITE W/ GC AND SUBCONTRACTOR,OBSE... | $625 | $0 | May 28, 2019 |
| May 10, 2014 | 35076032N | RESOLVE | CLASS - 2 | WORK W/O PERMIT.WORK NOTED:@ FRONT OF PREMISES ENCLOSED ENTIRE FRONT PORCH.ENCLOSURE HAS(12)WINDOWS 7 (1)ENTRY DOOR W... | $800 | $0 | Jun 24, 2014 |
| Nov 28, 2003 | 34422932L | RESOLVE | Hazardous | WORK WITHOUT PERMITS. WORK NOTED: AT CELLAR ERECTED PARTITIONS CREATING 3 ROOMS AND A BATHROOM, INSTALLED WATER AND W... | $0 | $0 | Nov 15, 2004 |
| Nov 28, 2003 | 34422933N | RESOLVE | Hazardous | FAILURE TO PROVIDE TWO MEANS OF EGRESS AT CELLAR, NO SECOND MEANS OF EGRESS ONE ENTRANCE AT REAR OF PREMISES. REMEDY:... | $480 | $0 | Nov 15, 2004 |
| Nov 27, 2003 | 34422931J | RESOLVE | Hazardous | RESIDENCE ALTERED FOR OCCUPANCY AS A DWELLING FOR MORE THAN THE LEGALLY APPROVED # OF FAMILIES BUILDING DEPT RECORDS ... | $3,050 | $0 | Nov 15, 2004 |