42-26 81 Street, Queens • Block 01526 • Lot 0016
21 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jul 25, 2023 | 39090901M | ACTIVE | CLASS - 2 | DOOR TO BOILER ROOM NOT FIRE PROOF,NO STORAGE IN BOILER ROOM, CORRECT ALL VIOLING CONDITIONS AND SUBMIT A CERTIFICATE... | $3,125 | $3,125 | Oct 3, 2023 |
| Dec 9, 2022 | 37024950K | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $625 | $0 | May 16, 2023 |
| Oct 10, 2014 | 35026957J | RESOLVE | CLASS - 1 | OCCUPANCY CONTRARY TO DOB RECORDS.DOB'S RECORDS INDICATE APT 46 AS A STUDIO APT ILLEGAL CONVERSION NOTED AT 4G CONVER... | $2,400 | $0 | Feb 3, 2015 |
| Oct 10, 2014 | 35026956H | RESOLVE | CLASS - 2 | WORK W/O PERMIT WORK NOTD AT APT 4G ERECTED FULL PARTITIONS TO SUB-DIVIDE STUDIO INTO AT 4 BEDROOM ALL WITH WORKING D... | $800 | $0 | Feb 3, 2015 |
| Sep 14, 2014 | 38231917R | RESOLVE | CLASS - 2 | 42N10,56Y02,56T13. 42N10-BYPASSED FUSE ON CONTROLLER. | $500 | $0 | Nov 18, 2014 |
| Sep 14, 2014 | 38231918Z | RESOLVE | CLASS - 2 | 05I11,34O02,56Y02,56Y13,16E01. 05I11-CAR DOOR VISION GLASS DAMAGED REPLACE GLASS; 16E01-NUMEROUS FLOORS HATCH DOOR SL... | $500 | $0 | Nov 18, 2014 |
| Aug 12, 2009 | 38205332M | RESOLVE | CLASS - 2 | 70O02,71X10,52M07,68M07,69M07,14M07,41T07. 52M07- PROVIDE SPIN OUT DEVICE ON HOIST ROPES SHACKLES. | $250 | $0 | Oct 6, 2009 |
| Dec 19, 2008 | 36007007Z | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE SIXTH ROUND TECHINICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF ... | $0 | $0 | Mar 24, 2009 |
| May 5, 2006 | 38158352K | RESOLVE | Non-Hazardous | 51B07. (51)USE SAME SHACKLE CAR & COUNTERWEIGHT. | $350 | -$350 | Jan 9, 2007 |
| Aug 22, 2005 | 38154182Z | RESOLVE | Non-Hazardous | 83X10. (83)RESTORE TO SERVICE SO A FULL INSPECTION CAN BE MADE | $0 | $0 | Oct 11, 2005 |
| May 16, 2005 | 38152111M | RESOLVE | Non-Hazardous | 83X10. (83)-RESTORE TO SERVICE SO A FULL INSPECTION CAN BE MADE | $0 | $0 | Sep 6, 2005 |
| Apr 25, 2005 | 38151699H | RESOLVE | Non-Hazardous | 83X10. (83)RESTORE TO SERVICE SO A FULL INSPECTION CAN BE MADE | $350 | $0 | Sep 6, 2005 |
| Mar 25, 1998 | 38072168N | RESOLVE | Non-Hazardous | 75U5. | $0 | $0 | May 12, 1998 |
| Mar 25, 1998 | 38072167L | RESOLVE | Non-Hazardous | 75U5. | $0 | $0 | May 12, 1998 |
| Oct 14, 1995 | 38051423Z | RESOLVE | Non-Hazardous | 22D,57O,35P.35-=PROVIDE ACCESS TO MOTOR ROOM. | $0 | $0 | Dec 26, 1995 |
| Oct 14, 1995 | 38051422R | RESOLVE | Non-Hazardous | 08V,57O,35P.35-PROVIDE ACCESS MOTOR ROOM. | $0 | $0 | Dec 26, 1995 |
| Jan 9, 1995 | 38045776N | RESOLVE | Non-Hazardous | 53L, 53M, 17L, 22D. 53--PROVIDE MISSING LIGHTING FIXTURE OVER MACHINEAREA. 17--LOBBY, 5FL REPLACE WITH CLEAR WIRE GLA... | $100 | $0 | Mar 28, 1995 |
| Jan 9, 1995 | 38045525Z | RESOLVE | Non-Hazardous | 55L, 53M. 53--OVERHEAD LIGHT FIXTURE FOR MACHINE AREA MISSING,REPLACEIMMEDIATLY. 15--REPLACE ALL MISSING DUST COVERS. | $100 | $0 | Mar 28, 1995 |
| Oct 18, 1993 | 38038627Y | RESOLVE | Non-Hazardous | 08V,28H. | $0 | $0 | Nov 30, 1993 |
| Oct 18, 1993 | 38038626M | RESOLVE | Non-Hazardous | 08V. | $0 | $0 | Nov 30, 1993 |
| Jul 12, 1991 | 38008178K | RESOLVE | Non-Hazardous | 14M,07#,07 ADJUST DOOR REOPENING (STALLS) | $0 | $0 | Oct 29, 1991 |