| Feb 4, 2026 | 39176003H | RESOLVE | CLASS - 2 | MISSING SIGHT GLASS ON REAR DOOR, MISSING LUGS ON FRONT AND REAR DOORS, BROKEN STUDS ON DOORS. CORRECT ALL VIOLATING ... | $1,250 | $1,250 | Apr 14, 2026 |
| Oct 1, 2024 | 37030089N | ACTIVE | CLASS - 1 | FAILURE TO SUBMIT THE REQUIRED PARKING STRUCTURE INITIAL OBSERVATION REPORT FOR AN EXISTING PARKING STRUCTURE DOCUMEN... | $12,500 | $12,500 | Jan 14, 2025 |
| Mar 19, 2024 | 37027165Z | ACTIVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS #39041113K ISSUED ON 5/13/2021, AND FAILURE TO FILE ... | $1,250 | $1,250 | Jun 11, 2024 |
| Nov 7, 2022 | 39073509N | RESOLVE | CLASS - 1 | ELEVATOR IN BUILDING OUT OR SERVIVE . UPON INSPECTION THE DEVICE IS FOUND TO BE OUT OF SERVICE CREATING A HAZARDOUS C... | $1,250 | $1,250 | May 9, 2023 |
| Jun 6, 2022 | 39063526X | ACTIVE | CLASS - 2 | AT TIME OF MY INSPECTION I OBSERVED CONSTRUCTION DEBRIS AND MATERIAL AT THE BOTTOM OF FIRE ESCAPE STEPS AT THE FRONT ... | $10,000 | $10,000 | Jul 26, 2022 |
| May 22, 2021 | 35559374J | ACTIVE | CLASS - 2 | TEMPORARY CONSTRUCTION EQUIPMENT ONSITE-SIDEWALK SHED WITH EXPIRED PERMIT-NOTE:AT THE TIME OF MY INSPECTION I OBSERVE... | $6,250 | $6,250 | Aug 10, 2021 |
| May 22, 2021 | 35559373H | ACTIVE | CLASS - 2 | BC 3307.6.4.6 PARAPET NOTE:AT THE TIME OF MY INSPECTION I OBSERVED A SIDEWALK SHED ERECTED AT EXPOSURE ONE.I ALSO OBS... | $6,250 | $6,250 | Aug 10, 2021 |
| May 13, 2021 | 35510957Y | RESOLVE | CLASS - 1 | BC90728-FAILURE TO PROVIDE FIRE ALARM SYSTEM FOR TRANSIENT USE AT APT#5P.REMEDY:DISCONTINUE ILLEGAL OCCUPANCY. | $2,500 | $2,500 | Aug 3, 2021 |
| May 13, 2021 | 35510958X | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING I CODE-COMPLIANT MANNER.LACK OF A SYSTEMOF AUTOMATIC SPRINKLER WHERE IS REQUIRED AS PER ... | $1,250 | $1,250 | Aug 3, 2021 |
| May 13, 2021 | 35510956M | RESOLVE | CLASS - 2 | PERMANET DWELLING USED/CONVERTED FOR OTHER THAN PERMANENT-RESIDENTIAL PURPOSES.COFO#139326 INDICATES BUILDING TO BE L... | $2,500 | $2,500 | Aug 3, 2021 |
| May 13, 2021 | 39041113K | ACTIVE | CLASS - 2 | WORK WITHOUT A PERMIT. AT APARTMENT 6K LIVING ROOM AREA ERECTED AND INSTALLED FULL HEIGHT PARTITIONS TO CREATE ADDITI... | $1,250 | $630 | Jun 29, 2021 |
| Feb 26, 2021 | 39036865R | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... | $1,250 | $1,250 | Jun 1, 2021 |
| Feb 26, 2021 | 39036864P | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... | $1,250 | $1,250 | Jun 1, 2021 |
| Aug 11, 2020 | 39026768X | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... | $1,250 | $0 | Sep 29, 2020 |
| Aug 11, 2020 | 39026769H | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... | $1,250 | $0 | Sep 29, 2020 |
| Oct 20, 2017 | 38257999P | RESOLVE | CLASS - 1 | 32L10.(32L10)SHOE GUIDES WORN MUST REPAIRED OR REPLACED.DURING THE MOVEMENT THE CABIN IS SHAKING. | $1,000 | $0 | Dec 5, 2017 |
| Aug 22, 2012 | 38223077N | RESOLVE | CLASS - 3 | 70O02,15B11,71X10,100I10. 100I- HANDRAIL TO MACHINE ROOM. | $0 | $0 | Oct 9, 2012 |
| Oct 4, 2011 | 38218530X | RESOLVE | CLASS - 2 | 100E10/ 15B11/ 70O02/ 100E10 - DOOR CLUTCH RUBBING FACIA IS GOING UP &ON SHAFT | $250 | $0 | Nov 22, 2011 |
| Aug 11, 2011 | 34928100R | RESOLVE | CLASS - 2 | 27-203MISC.VIO.FAILURE TO COMPLY W/SAFETY REQUIREMENTS DURING CONSTRUCTION OPERATIONS AS PER 27-203.@ FRONT LEADING T... | $800 | $0 | Jan 17, 2012 |
| Aug 4, 2011 | 34917866R | RESOLVE | CLASS - 2 | 3307.5.2MISC.VIO. FAILURE TO HAVE FLAG PERSON.@ THE TIME OF MY INSPEC.APPROX. 3 WORKERS ON SITE INCLUDING CONCRETE TR... | $800 | $0 | Sep 20, 2011 |
| Feb 4, 2011 | 38215200J | RESOLVE | CLASS - 3 | 71X10,70O02. | $500 | $0 | Mar 22, 2011 |
| Feb 4, 2011 | 38215201L | RESOLVE | CLASS - 2 | 40I11,70O02.40-I-11. REPLACE ALL BROKEN WINDOWS IN MACH. RM. | $2,500 | $0 | Mar 22, 2011 |
| Dec 30, 2008 | 38199526M | RESOLVE | CLASS - 3 | 98,BB,05 | $100 | $0 | Feb 24, 2009 |
| Dec 30, 2008 | 38199527Y | RESOLVE | CLASS - 3 | 98,BB,05 | $100 | $0 | Feb 24, 2009 |
| Jun 12, 2008 | 34654214J | ACTIVE | Non-Hazardous | WORK W/O A PERMIT. WORK NOTED: AT APT #2E ERECTED FULL HEIGHT PARTITION WITH A DOOR CREATING 1 ADDITIONAL ROOM. AT AP... | $500 | $0 | Jan 19, 2010 |
| Mar 3, 2008 | 38182405P | RESOLVE | Non-Hazardous | 17H1185BB0586BB05. (17H11) DOOR GIBS WORN ON 2ND FLR. (85BB05) 5 YEAR EXPIRED (11/2002) (86-BB-05) 2 YEAR EXPIRED (02... | $180 | $0 | Apr 22, 2008 |
| Mar 3, 2008 | 38182406R | RESOLVE | Non-Hazardous | 85BB0517H1121M0740I1040D0639M0751O0260G1186BB05. SECOND OFFENSE (85BB05) DOB INDICATES 5 YEAR TEST EXPIRED (11/2002) ... | $1,000 | $0 | Apr 22, 2008 |
| Jan 23, 2008 | 38180940H | RESOLVE | Non-Hazardous | 21L10.45R11.05A10.45D06.85BB05. CEASE USE 21L10-ENTRAMPMENT ON 6TH FL DOORS DONT OPEN 45R11-UP THE (CORNER ) SWITCH I... | $800 | $0 | Mar 18, 2008 |
| Aug 1, 2007 | 38166596R | RESOLVE | Non-Hazardous | 05E01.33O02.38O02.39P07.66O02.84O02.05E01-CAR DOOR CLUTCH SCROPING HOISTWAY DOOR ROLLERS.84O02-CLEAN CAR & ALL HOISTW... | $0 | $0 | Sep 25, 2007 |
| Aug 1, 2007 | 38166597Z | RESOLVE | Non-Hazardous | 07#01.33O02.38O02.39P07.66O02.84O02.07#01-ADJUST DOOR OPERATOR (DOOR OPENING BEFORE LEVELING).84O02-CLEAN ALL HOISTWA... | $0 | $0 | Sep 25, 2007 |
| Aug 21, 1999 | 34225242L | RESOLVE | Hazardous | WORK WITHOUT A PERMIT. WORK NOTED: AT CELLAR PARTITIONS ERECTED CREATING 3 PIECE BATHROOM. REMEDY: OBTAIN PERMIT OR R... | $0 | $0 | Feb 23, 2000 |
| Aug 21, 1999 | 34225241J | RESOLVE | Hazardous | OCCUPANCY CONTRARY TO THAT OF CERTIFICATE OF OCCUPANCY #139326. C OF O INDICATES CELLAR TO BE LEGALLY APPROVED FOR 1 ... | $0 | $0 | Feb 23, 2000 |
| Aug 21, 1999 | 34225240H | RESOLVE | Hazardous | RESIDENCE ALTERED FOR OCCUPANCY AS A DWELLING FOR MORE THAN THE LEGALLY APPROVED # OF FAMILIES. CERTIFICATE OF OCCUPA... | $0 | $0 | Feb 23, 2000 |
| Feb 23, 1995 | 38047430P | RESOLVE | Non-Hazardous | 15B,21X,22D,35O,57O,58O,59O.15-ADJUST SLL DOORS TO MAKE SELF-CLOSING. | $0 | $0 | May 16, 1995 |
| Feb 23, 1995 | 38047429H | RESOLVE | Non-Hazardous | 14I, 15B, 28H, 36W, 37G, 57O, 58O, 59O, 08J, 73O. 15-ADJUST ALL HOISTWAY DOORS TO MAKE SELF-CLOSING. REPLACE MISSING ... | $0 | $0 | May 16, 1995 |
| Jul 3, 1990 | 38000083L | RESOLVE | Non-Hazardous | 03L,03M,50Y,22D,74O, (03)REPAIR FAN ON TOP OF CAR (03)PROVIDE CAPACITYPLATE (74)CLEAN TOP OF ELEVATOR OF OIL & DEBRIS. | $150 | $0 | Oct 2, 1990 |
| Jul 3, 1990 | 38000084N | RESOLVE | Non-Hazardous | 03L,03M,50Y,74O,53L, (03)REPAIR FAN (03)PROVIDE CAPACITY PLATE (50)RE-MOVE OIL (74)CLEAN CAR TOP. (53)REPAIR MOTOROOM... | $150 | $0 | Oct 2, 1990 |