Skip to content

Maintenance code violations

27-51 Butler Street, Queens • Block 01665 • Lot 0046

13 records

HPD grades a violation A for non-hazardous through C for immediately hazardous.

Issued Class Status Violation Apartment Correct by
May 29, 2008 B SECOND NO ACCESS TO RE-INSPECT VIOLATION SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE LIGHT FIXUTRE AT CEILING 1ST STY. SHARED SPACE. Jul 3, 2008
May 29, 2008 B SECOND NO ACCESS TO RE-INSPECT VIOLATION SECTION 27-2026 ADMIN. CODE: REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLO... Jul 3, 2008
May 29, 2008 B SECOND NO ACCESS TO RE-INSPECT VIOLATION SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PLASTERBOARD CEILING AT CE... Jul 3, 2008
May 29, 2008 B SECOND NO ACCESS TO RE-INSPECT VIOLATION SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING LIGHT FIXTURE ON NORTH WALL AT PRIVATE HALL NEAR REAR NORTH... Jul 3, 2008
May 29, 2008 B SECOND NO ACCESS TO RE-INSPECT VIOLATION SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR AT NORTH WEST C... Jul 3, 2008
May 29, 2008 B SECOND NO ACCESS TO RE-INSPECT VIOLATION SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ACCUMULATION OF WOOD, CARTONS RAGS, DISUSED FURNITURE A... Jul 3, 2008
May 29, 2008 C SECOND NO ACCESS TO RE-INSPECT VIOLATION SECTION 27-2026 ADMIN. CODE: REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLO... Jun 4, 2008
May 29, 2008 B SECOND NO ACCESS TO RE-INSPECT VIOLATION SECTION 27-2010,2011,2012 ADMIN. CODE: CLEANSE AND DISINFECT TO THE SATISFACTION OF THIS DEPARTMENT AFTER REMOVING TH... Jul 3, 2008
May 29, 2008 C SECOND NO ACCESS TO RE-INSPECT VIOLATION SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE DROPPED MASONRY FLOOR BATH... Jun 4, 2008
May 29, 2008 C SECOND NO ACCESS TO RE-INSPECT VIOLATION SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE CEILING BEAMS WET AND ROTTEN CELLAR CENTER. Jun 4, 2008
May 29, 2008 B SECOND NO ACCESS TO RE-INSPECT VIOLATION SECTION 27-2005 ADMIN. CODE: PROVIDE ELECTRIC SERVICE ALL ROOMS ENTIRE 1ST STY. AND CELLAR 1ST STY. APT. AND CELLAR. Jul 3, 2008
May 29, 2008 B SECOND NO ACCESS TO RE-INSPECT VIOLATION SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE ROOF OF REAR YARD GARAGE - USED AS A PORCH Jul 3, 2008
May 29, 2008 B SECOND NO ACCESS TO RE-INSPECT VIOLATION SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE WINDOW SASHES AND GLASS AT REAR PORCH 2ND STY. ... Jul 3, 2008