| Sep 22, 2015 | 35036416X | RESOLVE | CLASS - 1 | WORK W/O PERMIT WORK NOTED AT CELLAR AND 1ST FLR REAR. ERECTED FULL PARTITION FOR 4 ROOMS AND 2 BATHROOMS. INSTALLED ... | $1,600 | $0 | Feb 2, 2016 |
| Sep 22, 2015 | 35036417H | RESOLVE | CLASS - 1 | RESIDENCE ALTERED FOR OCCUPANCY AS A DWELLING FROM 2FAMILIES TO 4FAMILIES. DOB RECORDS INDICATE RESIDENCE AS A 2FAMIL... | $38,400 | $38,400 | Feb 2, 2016 |
| Jun 8, 2011 | 34903512M | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER TO FILE A C/C W/THE DOB. RESPONDENT FAILED TO COMPLY W/THE COMMISSIONER'... | $0 | $0 | Aug 30, 2011 |
| Jun 8, 2011 | 34903511K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN A CODE-COMPLIANT MANNER. NOTED: GUARD RAILMISSING AT STAIR LEADING TO CELLAR AT FRONT AND... | $0 | $0 | Aug 30, 2011 |
| Jun 8, 2011 | 34903513Y | RESOLVE | CLASS - 1 | FILED A C/C OR OTHER RELATED MATERIALS CONTAINING FALSE MATERIAL STATEMENTS. RESPONDENT FILED A C/C ON 6.6.11 FOR NOV... | $4,800 | $0 | Aug 30, 2011 |
| Apr 21, 2011 | 34903084P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN A CODE-COMPLIANT MANNER. NOTED: NO HAND RAILS OR GUARD RAILS AT STAIR LEADING TO CELLAR A... | $0 | $0 | Jun 21, 2011 |
| Oct 10, 2008 | 34716936M | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR ... | $4,000 | $0 | Dec 23, 2008 |
| Oct 10, 2008 | 34691102H | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES. NOTED CHIMNEY HAS LOOSE A MISSING MORTAR A BRICKS. AT REAR RIGHT... | $5,000 | $0 | Dec 23, 2008 |
| Oct 10, 2008 | 34716937Y | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDING FOR N... | $4,000 | $0 | Dec 23, 2008 |
| Oct 30, 2007 | 34620558H | RESOLVE | Non-Hazardous | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DOB FOR VIOLATIONS 1.3447... | $2,500 | $0 | Dec 18, 2007 |
| Oct 30, 2007 | 34620559J | RESOLVE | Non-Hazardous | FAILURE TO COMPLY WITH AN ORDER OF THE DEPARTMENT. NOTED PREMISES ISSUED FAILURE TO MAINTAIN NOV'S FOR DEFECTIVE CHIM... | $5,000 | $0 | Dec 18, 2007 |
| Jul 6, 2007 | 34580190P | RESOLVE | Hazardous | FAILURE TO MAINTAIN.NOTE:FRONT STOOP IN DISREPAIR CAUSING A TRIPPING HAZARD ALSO CHIMNEY AT REAR NEEDS REPAIRING.REME... | $10,000 | $0 | Aug 28, 2007 |
| Mar 14, 2007 | 34560599M | RESOLVE | Hazardous | FAILURE TO MAINTAIN..NOTE:FRONT STOOP & CHIMNEY IN DISREPAIR..REMEDY: MAINTAIN PROPERTY/BLDG. | $10,000 | $0 | May 22, 2007 |
| Nov 3, 2006 | 34545155X | RESOLVE | Hazardous | FAILURE TO MAINTAIN.NOTED:CHIMNEY & FRONT STOOP/STEPS TO MAIN ENTRANCEIN DISREPAIR.REMEDY:MAINTAIN/REPAIR PROPERTY/BLDG. | $10,000 | $0 | Dec 19, 2006 |
| Jul 15, 2006 | 34528504K | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR BLDG DEFECTS NOTED:CHIMNEY OUT OF PLUMB &MISSING MORTAR JOISTS & FRONT STOOP IS IN DISRE... | $10,000 | $0 | Aug 29, 2006 |
| Mar 10, 2006 | 34505287L | RESOLVE | Hazardous | FAILURE TO MAINTAIN NOTE FRONT STOP IS IN DISREPAIR AND IS CREATING A TRIPPING HAZARD. REMEDY MAINTAIN DWELLING REPAI... | $10,000 | $0 | Apr 25, 2006 |
| Mar 10, 2006 | 34505286J | RESOLVE | Hazardous | FAILURE TO MAINTAIN. NOTE AT REAR OF DWELLING CHIMNEY IS OUT OF PLOMB AND MISSING MORTAR JOINTS. REMEDY. MAINTAIN BUI... | $10,000 | $0 | Apr 25, 2006 |
| Nov 17, 2005 | 34405673L | RESOLVE | Hazardous | FAILURE TO MAINTAIN. NOTE: FRONT STOOP IS IN DISREPAIR. CREATING A TRIPPLING HAZARD. REMEDY: MAINTAIN DWELLING/STOOP ... | $2,500 | $0 | Jan 10, 2006 |
| Nov 17, 2005 | 34405672J | RESOLVE | Hazardous | FAILURE TO MAINTAIN. NOTE: AT REAR OF DWELLING CHIMNEY IS OUT OF PLUMB, MISSING MORTAR JOINTS AND MISSING BRICK. REME... | $10,000 | $0 | Jan 10, 2006 |
| Aug 18, 2005 | 34490901N | RESOLVE | Hazardous | AT FRONT OF BUILDING CONCRETE STEPS ARE SEPARATING AND MISSING CONCRETE. REMEDY: MAINTAIN FRONT STEPS. | $10,000 | $0 | Oct 4, 2005 |
| Jul 8, 2005 | 34475272Y | RESOLVE | Hazardous | FAILURE TO MAINTAIN BUILDING. DEFECT NOTED: - CHIMNEY IS OUT OF PLUMB MISSING MORTAR JOINTS AND MISSING BRICK. REMEDY... | $10,000 | $0 | Aug 23, 2005 |
| Apr 28, 2005 | 34472949N | RESOLVE | Hazardous | 20050816Y, SPLIT AND MISSING CONCRETE. REMEDY: MAINTAIN BUILDING. | $10,000 | $0 | Aug 16, 2005 |
| Mar 24, 2005 | 34471446R | RESOLVE | Hazardous | FAILURE TO MAINTAIN BUILDING.DEFECT NOTED:CHIMNEY IS OUT OF PLUMB MISSING MORTAR JOISTS AND ALSO MISSING BRICK AT VAR... | $2,500 | $0 | May 10, 2005 |
| Dec 14, 2004 | 34492353K | RESOLVE | Hazardous | FAILURE TO MAINTAIN: 1) ENTRY CONCRETE STEPS IN DISREPAIR BROKEN, SPLIT AND MISSING CONCRETE. 2) CHIMNEY HAS LOOSE BR... | $10,000 | $0 | Feb 1, 2005 |
| Aug 17, 2004 | 34443916Y | RESOLVE | Hazardous | FAILURE TO MAINTAIN NOTE: NOTE: 1) FRONT ENTRY STEPS ARE CRACKED AND BROKEN. 2) CHIMNEY HAS DISPLACED BRICKS WITH MOR... | $10,000 | $0 | Oct 5, 2004 |
| Apr 28, 2004 | 34433915N | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXT. BUILDING WALL.1)CHIMNEY IS IN DISREPAIR W/LARGE BRICKS IN DANGER OF FALLING.2)FRONT ENTRANCE... | $0 | $0 | Jul 25, 2006 |
| Nov 14, 2003 | 34417425K | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR BLDG WALL(CHIMNEY BRICKWORK AND MASONARY FRONT STEPS)NOTED:CRACKED BRICKS AND MORTAR JOI... | $2,500 | $0 | Dec 30, 2003 |
| Apr 14, 1998 | 34174565Z | RESOLVE | Hazardous | WORK WITHOUT A PERMIT. WORK NOTED: IN CELLAR PARTITIONS ERECTED CREATING 4 RMS (VACANT AT TIME OF INSPECTION). KITCHE... | $2,500 | $0 | Jun 13, 2000 |
| Apr 14, 1998 | 34174566K | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN. NOTED: AT REAR & AT SIDE OF BLDG THERE IS AN ABUNDANCE OF DEBRIS (PLYWOOD, PLASTICS, CRATES, CHA... | $2,500 | $0 | Jun 2, 1998 |
| Sep 10, 1997 | 34162472L | RESOLVE | Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDING DEPARTMENT RECORDS, CELLAR CHANGED FRO... | $800 | $0 | May 13, 1998 |