ECB violations

55-44 97 Place, Queens • Block 01905 • Lot 0047

20 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Dec 22, 2025 35720505Z ACTIVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. LACK OF REQUIRED NUMBER OF MEANS OF EGRESS FOR EVERY FLOOR PER... $12,500 $12,500 Mar 3, 2026
Dec 22, 2025 35720506K RESOLVE CLASS - 1 BC 907.2.8. FAILURE TO PROVIDE A FIRE ALARM SYSTEM CLASS "J" FOR TRANSIENT USE AT UNIT #1A AT THE 1ST FLOOR. REMEDY: ... $6,250 $6,250 Mar 3, 2026
Dec 22, 2025 35720504R RESOLVE CLASS - 2 PERMANENT DWELLING USED/CONVERTED FOR OTHER THAN PERMANENT-RESIDENTIALPURPOSES. DOB RECORDS INDICATES PREMISES TO BE ... $5,000 $5,000 Mar 3, 2026
Jun 21, 2023 39088852M RESOLVE CLASS - 1 THE ONLY ELEVATOR IN BUILDING (OR SECTION OF BUILDING) OUT OF SERVICE. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT... $1,250 $0 Oct 24, 2023
Jan 18, 2022 35504338Y RESOLVE CLASS - 1 SEC. BC 3309.1 PROTECTION OF ADJOINING PROPERTIES. AT THE TIME OF INSPECTION OBSERVED 6 STY NEW RESIDENTIAL AT BLDG W... $2,500 $0 Jun 21, 2022
Jan 18, 2022 35504339X RESOLVE CLASS - 1 FAILED TO PROVIDE PEDESTRIAN PROTECTION FOR SIDEWALKS & WALKWAYS(NO SIDEWALK SHED). AT THE TIME OF A INSPECTION OF A ... $625 $0 Jun 21, 2022
Jan 18, 2022 35504337M RESOLVE CLASS - 2 SEC. BC 3307.6.5.11 FAILURE TO NOTIFY DOB OF SIDEWALK SHED REMOVAL. ATTHE TIME OF INSPECTION OF A 6 STY NEW RESIDENTI... $0 $0 Apr 19, 2022
Dec 7, 2021 39052414H RESOLVE CLASS - 2 EXTERIOR WALLS ON EXPOSURE 1 FROM GROUND LEVEL TO 1ST. FLOOR( FOR ELEVATOR WALLS) WERE INSTALLED WITH R-30 CAVITY INS... $640 $0 Jun 21, 2022
Sep 17, 2021 35589556H RESOLVE CLASS - 1 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS-NEEDLE BEAM AT EXP#2 NOT CONFORMI... $2,500 $0 Dec 14, 2021
Sep 17, 2021 35589555X RESOLVE CLASS - 1 FAILURE TO MAINTAIN/DISPLAY ONSITE DOCUMENT REQUIRED BY BC CHAPTER 33 NO LOAD IMPOSED LETTER AT SITE.AT THE TIME OF I... $1,250 $0 Dec 14, 2021
Aug 3, 2021 35583463L RESOLVE CLASS - 2 BC330721-FAILURE TO COMPLY WITH DOT STIPULATION/REGULATIONS.AT TIME OFINSPECTION THIS WAS 6 STORIED RESIDENTIAL BUILD... $0 $0 Jul 5, 2022
Aug 3, 2021 35583464N RESOLVE CLASS - 2 FAILURE TO INSTITUTE/MAINTAIN CONSTRUCTION FENCE AS PER SUBSECTION OF CODE REQUIREMENTS.AT THE TIME OF INSPECTION,THI... $0 $0 Oct 26, 2021
Jul 16, 2021 35585176H RESOLVE CLASS - 1 BC 3309.2 LICENSE TO ENTER ADJOINING PROPERTY. NOTE=AT THE TIME OF MY INSPECTION,I OBSERVED A ROOF PROTECTION ON ADJA... $2,500 $0 Oct 5, 2021
May 26, 2021 39041807P RESOLVE CLASS - 2 EXTERIOR WALLS ON EXPOSURE 2 ON 2ND., 4TH. AND 5TH. FLOOR WERE INSTALLED WITHOUT 2" SPACE BETWEEN CUM WALLS AND METAL... $0 $0 Jul 13, 2021
Jan 8, 2021 35544389K RESOLVE CLASS - 1 BC 3305.2.2 FIELD CONNECTION.NOTE:AT THE TIME OF MY INSPECTION OF AN 6STORY BUILDING WITH CONSTRUCTION WORK IN PROGRE... $2,500 $0 Jan 11, 2022
Jan 8, 2021 35544390H RESOLVE CLASS - 1 USE OF EXISTING STRUCTURES TO SUPPORT VERTICAL OR LATERAL LOADS. NOTE:AT THE TIME OF MY INSPECTION OF AN 6 STY BLDG W... $5,000 $0 Jan 11, 2022
Jan 8, 2021 35544391J RESOLVE CLASS - 1 FAILURE TO MAINTAIN RECORD OF PRE-SHIFT SAFETY MEETING FOR EACH WORKERNOTE:AT THE TIME OF MY INSPECTION OF AN 6 STORY... $5,000 $0 Jan 11, 2022
Jan 8, 2021 35544392L RESOLVE CLASS - 1 PERMIT HOLDER FAILED TO ENSURE WORKER RECIEVE SITE SAFETY ORIENTATION.NOTE:AT THE TIME OF MY INSPECTION OF A 6 STORY ... $2,500 $0 Jan 11, 2022
Jan 6, 2021 35542394X RESOLVE CLASS - 2 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS. AS NOTED:AT TIME OF INSPECTION A... $0 $0 Mar 30, 2021
Feb 29, 2020 35469107X RESOLVE CLASS - 2 FAILURE TO MAINTAIN/INSTITUTE SAFETY MEASURES-JOBSITE FENCE IN RESPONSE TO ABOVE MENTIONED COMPLAINT#4805891 OBSERVED... $0 $0 May 12, 2020