ECB violations
110-44 72 Road, Queens • Block 02237 • Lot 0028
12 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Mar 7, 2018 | 32093313P | ACTIVE | CLASS - 2 | 4A,16,19B,36. (36)FOUND HYDROTHERM GAS FIRED BOILER NOT REGISTERED. REGISTER THE BOILER, CORRECT ALL VIOLATING CONDIT... | $3,125 | $0 | Apr 24, 2018 |
| Mar 7, 2018 | 32093314R | ACTIVE | CLASS - 2 | 4A,16,19B,36. (36)FOUND HYDROTHERM GAS FIRED BOILER NOT REGISTERED. REGISTER THE BOILER, CORRECT ALL VIOLATING CONDIT... | $3,125 | $0 | Apr 24, 2018 |
| Mar 7, 2018 | 32093312N | ACTIVE | CLASS - 2 | 4A,15,16,19B,34A,36,50A-B. FOUND HYDROTHERM GAS FIRED BOILER NOT REGISTERED. (50A)FIRE DAMPER MISSING ON FRESH AIR IN... | $3,125 | $0 | Apr 24, 2018 |
| Apr 22, 2008 | 34644710J | RESOLVE | Non-Hazardous | WORK W/O A PERMIT: EXPIRED PERMIT FOR ALT 11 JOB #402310744. PERMIT HAS EXPIRED ON 4/12/07 & 3PC BATHROOM STILL IN PL... | $500 | $0 | Jun 17, 2008 |
| Apr 22, 2008 | 34644711L | RESOLVE | Non-Hazardous | FAILURE TO FILE TR1 PRIOR START OF CONTROLLED WORK FOR ALT II JOB 402310744. NO ARCHITECT OR ENGINEER HAS TAKEN THE R... | $0 | $0 | Aug 11, 2009 |
| Apr 22, 2008 | 34644709M | RESOLVE | Non-Hazardous | WORK DOES NOT CONFORM TO APPROVED PLANS FOR ALT2 #402310744 NON CONFORMING WORK FOUND 1 CELLAR PLANS INDICATES 2 FIXT... | $250 | $0 | Jun 17, 2008 |
| Dec 5, 2002 | 34375780M | RESOLVE | Hazardous | OCCUANCY CONTRARY TO THAT ALLOWED ACCORDING TO CERTIFICATE OF OCCUPANCY #Q197429. ILLEGAL OCCUPANCY NOTED AT CELLAR. ... | $0 | $0 | Aug 12, 2003 |
| Dec 5, 2002 | 34375779P | RESOLVE | Hazardous | WORK WITHOUT PERMITS. WORK NOTED: AT CELLAR ERECTED FULL HEIGHT PARTTIONS CREATING 2 ROOMS AND A BATHROOM INSTALLED W... | $800 | $0 | Aug 12, 2003 |
| Dec 5, 2002 | 34375778N | RESOLVE | Hazardous | RESIDENCE ALTERED FOR OCCUPANCY AS A DWELLING FOR MORE THAN THE LEGALLY APPROVED # OF FAMILIES CERTIFICATE OF OCCUACN... | $5,300 | $0 | Aug 12, 2003 |
| Sep 6, 2002 | 32034502Y | RESOLVE | Hazardous | 4A/ 19B/ 49 49-NO CHECK VALVE (BACK FLOW PREUEMTER) ON BOILER FEED LINE | $800 | $0 | Jan 3, 2006 |
| Sep 6, 2002 | 32034504H | RESOLVE | Hazardous | 4A/ 19B/ 49/ 36/ 49-NO CHECK VALVE(BACK FLOW PREUENTER) ON BOILER FEED LINE THIS BOILER HEATS COMMERICAL OFFICE" MUST... | $800 | $0 | Jan 3, 2006 |
| Sep 6, 2002 | 32034503X | RESOLVE | Hazardous | 4A/ 19B/ 49/ 49 NO CHECK VALVE (BACK FLOW PREVENTER) ON BOILER FEED LINE | $800 | $0 | Jan 3, 2006 |