Skip to content

ECB violations

59 Street, Queens • Block 02319 • Lot 0010

42 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Feb 19, 2026 39550561J ACTIVE CLASS - 2 DURING INSPECTION OF A 10 STORY BUILDING WITH A SIDEWALK SHED IN PLACE, DOB RECORDS REVEALED THAT THE PERMIT EXPIRED ... $6,250 $6,250 Apr 28, 2026
Feb 2, 2026 39549842H ACTIVE CLASS - 2 OBSERVED PERMITTED SIDEWALK SHED WITH LOOSE DEBRIS NETTING AND MISSING BOLT COVERINGS ON THE VERTICAL MEMBERS AT EXPO... $2,400 $2,400 Nov 23, 2026
Jan 28, 2026 39175199Y ACTIVE CLASS - 2 CONDENSATE PUMP LEAKING, CORRECT ALL VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION. $1,280 $1,280 Mar 29, 2027
Jan 27, 2026 35685915K RESOLVE CLASS - 3 FAILURE TO MAINTAIN BUILDING CODE-COMPLIANT MANNER. AS NOTED: AT TIME OF INSPECTION OBSERVED AT PARKING LOT A LAMP PO... $500 $500 Oct 2, 2026
Dec 8, 2025 39547703Z ACTIVE CLASS - 2 OBSERVED NO PARAPET INFORMATION PANEL ON THE PERMITTED SIDEWALK SHED AT EXPOSURE 1. THIS CREATES HAZARDOUS CONDITIONS... $1,250 $1,250 Sep 14, 2026
Dec 8, 2025 39547704K ACTIVE CLASS - 2 BC 3307.2.3 OBSERVED LOOSE DEBRIS NETTING AT SIDEWALK SHED AT THE ENTRANCE OF THE BUILDING & THE PEDESTRIAN PASSAGEWA... $2,500 $2,500 Sep 14, 2026
Oct 21, 2025 39546209Z ACTIVE CLASS - 2 AT THE TIME OF INSPECTION, THE SIDEWALK SHED WAS MISSING MULTIPLE POST SCREW CAPS TO PROTECT THE PUBLIC FROM INJURY. ... $10,000 $10,000 Jun 3, 2027
Sep 5, 2025 39159362P ACTIVE CLASS - 2 OBSERVED 3 WORKERS DOING REPAIRS TO FACADE USING SUSPENDED SCAFFOLD. NO NOTIFICATION/PERMIT ON FILE. STOP ALL WORK AT... $2,500 $2,500 Oct 5, 2026
Jan 26, 2023 35670430K ACTIVE CLASS - 2 FAILURE TO MAINTAIN BUILDING EXTERIOR WALL/FACADE AND APPURTENANCES:OBSERVED AT BALCONY SLAB CRACK AT VARIOUS FLOORS ... $1,250 $0 Apr 25, 2023
Jan 26, 2023 35670429N ACTIVE CLASS - 3 FAILURE TO POST EXTERIOR WALL CONDITION CERTIFICATE AS REQUIRED UNDER 1RCNY 103.04.NOTE:AT TIME OF INSPECTION OBSERVE... $500 $0 Apr 25, 2023
Dec 2, 2022 37024177M ACTIVE CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... $1,250 $0 Jun 6, 2023
Mar 8, 2021 39037306P ACTIVE CLASS - 2 HOIST ROPE SHORTENING. TROFT COVERS MISSING IN SHAFTWAY. PROVIDE. $625 $0 May 25, 2021
Mar 8, 2021 39037305N ACTIVE CLASS - 2 HOIST ROPE SHORTENING. $625 $0 May 25, 2021
Dec 20, 2017 38259718Z RESOLVE CLASS - 1 CEASE USE 5M7, 44Y13, 47O2, 40M7, 71X10 5M7-DOOR RESTRICTOR MISSING, 44Y13-TRACTION SHEAVE EXCESSIVE OIL LEAK. RE SEA... $1,000 $0 Feb 6, 2018
Jan 9, 2017 38252460Z RESOLVE CLASS - 2 52B11 HOIST ROPES SIZES IS INSUFFICIENT NEED TO REPLACE. $250 $0 Jun 13, 2017
Jan 9, 2017 38252461K RESOLVE CLASS - 2 52B11,80M07. 52B11-HOIST ROPES SIZES IS INSUFFICIENT NEED TO REPLACE $250 $0 Jun 13, 2017
Jan 8, 2016 35164463P RESOLVE CLASS - 3 BC3307.6 FAILURE TO MAINTAIN SIDEWALK SHED AS REQUIRED BY CODE. AT TIME OF INSPECTION: SIDEWALK SHED ERECTED UNDER 44... $0 $0 Feb 23, 2016
Sep 21, 2015 36023323K RESOLVE CLASS - 2 FAILURE TO FILE AN ACCEPTABLE TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS:PERIODIC INSPECTION OF EXTERIOR WAL... $2,000 $0 Feb 23, 2016
Jun 9, 2015 35133207Y RESOLVE CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BLDG EAST ELEV EXP1 FLAGS AND/OR FLOWER POTS BALCONY 4,9,14 SOUTH ELEV EXP2 BULGING MASO... $500 $0 Jul 28, 2015
Jan 6, 2015 35095394Y RESOLVE CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BLDG EAST ELEV.EXP#1 NO A/C COVER 5FL.WEST ELEV.EXP#3(REAR) TOP BALCONY CRACKS,DISPLACEM... $5,000 $0 Feb 24, 2015
May 12, 2014 36019188P RESOLVE CLASS - 2 FAILURE TO FILE AN ACCEPTABLE CYCLE 7 TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXT... $4,000 $0 Oct 14, 2014
Mar 11, 2014 35024221H RESOLVE CLASS - 2 FAILURE TO MAINTAIN EXT BLDG *EAST ELEVN,EXP #1 OBSERVE CRACKS & DETERIORATING IN BALCONY SLAP ON THE TOP FL(CENTER R... $500 $0 Apr 29, 2014
Mar 11, 2014 35024219Z RESOLVE CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BLDG EAST ELEVN,EXP #1 OBSERVE BLOCKS OF WOOD UNDER A/C UNIT IMPROPERLY INSTALLED;WEST E... $500 $0 Apr 29, 2014
Feb 26, 2013 38225697N RESOLVE CLASS - 2 34O02,39O02,40P16,67X10,70O2. CLEAN HOISTWAY, CLEAN CAR TOP - PROVIDE ACCESS TO M.R. PROVIDE PHONE CLEAN PIT. $0 $0 Apr 16, 2013
Feb 26, 2013 38225698P RESOLVE CLASS - 2 09B10,34O02,39O02,40P16,70B02,05M07. 09- CAR FLR FEELS HOLLOW UNDERNEATH, TILES SINK IN CHECK, REPAIR. 34-CLEAN. 39- ... $0 $0 Apr 16, 2013
Jun 30, 2011 36017228L RESOLVE CLASS - 2 FAILURE TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCEWITH CODE PROVISIONS: PERIODIC INSPECTION OF EX... $2,000 $0 Jan 3, 2012
May 26, 2011 34872474L RESOLVE CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BLDG EAST ELEV(EXP#1)OBSERVE CRACKS DETERIATING,DISLODGE AND BROKEN OFF CONCRETE BALCONY... $500 $0 May 8, 2012
Sep 20, 2010 36015266N RESOLVE CLASS - 2 FAILURE TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCEWITH CODE PROVISIONS: PERIODIC INSPECTION OF EX... $8,000 $0 Feb 22, 2011
Mar 3, 2010 38209198Z RESOLVE CLASS - 2 02X10,71X10,69M07. 02X- IN CAR ALARM BELL INOPERATIVE. $500 $0 Jun 25, 2013
Feb 17, 2010 36012116Y RESOLVE CLASS - 2 FAILURE TO FILE AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/ CODE PROVISIONS PERIODIC INSP OF EXTERIOR... $2,000 $0 May 8, 2012
Jun 10, 2009 38203715K RESOLVE CLASS - 2 16L01.67X10.69M7. 16L01 REDUCE SPACE ON BACK OF LOBBY HATCH DOOR 67X10 IN CAR EMERGENCY PH INOPERATIVE $500 $0 May 8, 2012
Jan 23, 2009 36007900L RESOLVE CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISION:PERIODIC INSPECTION OF EX... $800 $0 Jul 7, 2009
Jun 20, 2007 38167445Y RESOLVE Non-Hazardous 40T7/86BB5/66O2/.40T-PROVIDE PROPER SIGNAGE MOTOR ROOM DOOR. $1,250 -$1,250 Apr 7, 2009
May 8, 2007 38166601M RESOLVE Non-Hazardous 5A10/17H11/17R11/33Q3/38O2/55Y13/55Y2/84X10/86BB5/.5A10-REPAIR CAR DOOR OPEN-DOORS OPEN TO FAST-SLAM.17H11-REPLACE HO... $350 $0 May 8, 2012
May 2, 2007 38166395K RESOLVE Non-Hazardous 5O2/17H11/17R11/33O2/38X10/38M7/64X10/86BB5/.5-O-2-CAR DOOR TRACK & HANGER ROLLERS DIRTY-NOT OPENING & CLOSING SMOOTH... $350 $0 Jan 26, 2010
Apr 17, 2007 38165965Z RESOLVE Non-Hazardous 17H11,17M07,19M07,34Q07,17R11,38O02,39O02,40T07,55Y13,66O02,84I11,86BB05,33O02.17H11-REPLACE WORN HOISTWAY DOOR GIBS ... $350 $0 Oct 16, 2007
Apr 17, 2007 38165966K RESOLVE Non-Hazardous 17M07,17R11,19M07,33O02,39O02,55Y13,66O02,86BB05.17M07-FIRE GIBS MISSING ON FL 1,4,9.17R11-REPLACE AS NEEDED ALL HOIS... $350 $0 Oct 16, 2007
Apr 8, 2002 32033732P RESOLVE Non-Hazardous 34A $180 $0 Feb 25, 2003
May 2, 1998 38073238Y RESOLVE Non-Hazardous 50Y,46Y, 46-OIL SOAKED $0 $0 Jun 23, 1998
May 2, 1998 38073240N RESOLVE Non-Hazardous 50Y,46Y,74Y, 46-OIL SOAKED 74-TOP OF CAR CLEAN UP OIL $0 $0 Jun 23, 1998
May 2, 1998 38073239X RESOLVE Non-Hazardous 50Y-OIL LEAK $0 $0 Jun 23, 1998
Aug 7, 1992 38027202P RESOLVE Non-Hazardous 50H11, 5702 $0 $0 Sep 22, 1992