ECB violations

51 Avenue, Queens • Block 02453 • Lot 0040

101 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Apr 23, 2026 39185884L ACTIVE CLASS - 1 OBSERVED AT TIME OF INSPECTION 2 BOILERS NOT WORKING DUE TO CRACKED HEAT TUBES. TENANTS HAVE NO HOT WATER OR HEAT. PE... $2,530 $2,530 Jun 30, 2026
Feb 9, 2026 39176516N ACTIVE CLASS - 1 FOUND FEDERAL MODEL FST150 OIL FIRED BOILER CEASED USED DUE TO HAZARDOUS CONDITION. (COMBUSTION CHAMBER FULL OF WATER... $2,530 $0 Apr 21, 2026
Dec 9, 2025 39169851P RESOLVE CLASS - 1 CLASS 1 CEASE USE ITEM: DOOR ZONE RESTRICTOR INOPERATIVE. THIS IS A SAFETY FEATURE WHICH ENSURES PASSENGER SAFETY. RE... $1,250 $0 Feb 17, 2026
Dec 5, 2025 39169493Y ACTIVE CLASS - 2 OBSERVED FIRE DEPARTMENT CONNECTION LACKING CLEARANCES, INADEQUATE SPRINKLER COVERAGE THROUGH THE BUILDING, UNPROTECT... $1,250 $1,250 Aug 18, 2026
Aug 27, 2025 39158519J RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT TIME OF INSPECTION I OBSERVED NO SPRINKLER PROTECTION IN IN... $0 $0 Dec 23, 2025
Jul 22, 2025 39154511R RESOLVE CLASS - 1 THE ONLY ELEVATOR IN BUILDING (OR SECTION OF BUILDING) OUT OF SERVICE. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT... $6,250 $6,250 Oct 20, 2026
Jul 22, 2025 39154509H RESOLVE CLASS - 1 THE ONLY ELEVATOR IN BUILDING (OR SECTION OF BUILDING) OUT OF SERVICE. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT... $1,250 $0 Oct 20, 2026
Jul 22, 2025 39154510P RESOLVE CLASS - 1 THE ONLY ELEVATOR IN BUILDING (OR SECTION OF BUILDING) OUT OF SERVICE. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT... $1,250 $1,250 Oct 20, 2026
Jul 21, 2025 39154407R RESOLVE CLASS - 1 THE ONLY ELEVATOR IN BUILDING (OR SECTION OF BUILDING) OUT OF SERVICE. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT... $6,250 $0 Oct 20, 2026
Jul 21, 2025 39154406P RESOLVE CLASS - 1 THE ONLY ELEVATOR IN BUILDING (OR SECTION OF BUILDING) OUT OF SERVICE. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT... $1,250 $0 Oct 20, 2026
Jul 21, 2025 39154405N RESOLVE CLASS - 1 THE ONLY ELEVATOR IN BUILDING (OR SECTION OF BUILDING) OUT OF SERVICE. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT... $1,250 $1,250 Oct 20, 2026
Jul 2, 2025 39152659Y RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSP... $3,125 $0 Dec 8, 2026
Jul 2, 2025 39152658M RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSP... $3,125 $0 Dec 8, 2026
Jun 11, 2025 39150738N RESOLVE CLASS - 2 FAILURE TO SUBMIT CERTIFICATE OF CORRECTION FOR VIOLATION # 39139514R, FILE A CERTIFICATE OF CORRECTION $1,250 $1,250 Oct 20, 2026
Apr 2, 2025 39143614X ACTIVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. UPON INSPECTION, THE DEVICE IN A FAMILY SHELTER, WITH 216 DWEL... $1,250 $0 Feb 10, 2026
Apr 2, 2025 39143615H RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. UPON INSPECTION, THE DEVICE IN A FAMILY SHELTER, WITH 216 DWEL... $1,250 $0 Feb 10, 2026
Feb 25, 2025 39139518Y RESOLVE CLASS - 2 CLASS 2 ITEMS: IN-CAR COMMUNICATION INOPERATIVE. TOP OF CAR LIGHTING INOPERATIVE. REPLACE CAR DOOR RETAINERS (GIBS) A... $655 $0 Feb 26, 2026
Feb 25, 2025 39139536H RESOLVE CLASS - 2 I OBSERVED TWO 400 AMP DISCONNECTS IN THE MAIN ELECTRICAL ROOM IMPROPERLY BONDED BEYOND THE SERVICE DISCONNECT SWITCH... $2,000 $0 Jun 9, 2026
Feb 25, 2025 39139535X RESOLVE CLASS - 2 UNLAWFUL ACTS FAILURE TO COMPLY WITH COMMISSIONER'S ORDER AS STATED IN ECB# 39072207N ISSUED ON 10/18/2022 AND CORREC... $0 $0 May 6, 2025
Feb 25, 2025 39139514R RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 ... $2,500 $2,500 Jun 16, 2026
Feb 25, 2025 39139515Z ACTIVE CLASS - 2 EXIT DOOR NOT SELF-CLOSING. OBSERVED NON SELF CLOSING DOORS THROUGHOUT BUILDING. POTENTIAL FIRE HAZARD., REPAIR/REPLA... $625 $0 Jun 16, 2026
Feb 25, 2025 39139520N RESOLVE CLASS - 2 CLASS 2 ITEM: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT O... $625 $0 May 6, 2025
Feb 25, 2025 39139519X RESOLVE CLASS - 2 CLASS 2 ITEMS: IN-CAR COMMUNICATION INOPERATIVE. TOP OF CAR LIGHTING INOPERATIVE. REPLACE CAR DOOR RETAINERS. (GIBS) $655 $0 Feb 26, 2026
Feb 25, 2025 39139534Y RESOLVE CLASS - 2 UNLAWFUL ACTS: FAILURE TO COMPLY WITH COMMISSIONER'S ORDER AS STATED IN ECB# 39072210Y ISSUED ON 10/18/2022 AND CORRE... $0 $0 May 6, 2025
Feb 25, 2025 39139533M RESOLVE CLASS - 2 UNLAWFUL ACTS: FAILURE TO COMPLY WITH COMMISSIONER'S ORDER AS STATED IN ECB #39072209R ISSUED ON 10/18/2022 AND CORRE... $0 $0 May 6, 2025
Feb 25, 2025 39139540K RESOLVE CLASS - 2 I OBSERVED IN THE ELEVATOR MOTOR ROOM THE FAILURE TO SUPPORT THE CONDUIT FROM THE DISCONNECT TO THE ELEVATOR CONTROL ... $500 $0 Jun 9, 2026
Feb 25, 2025 39139541M ACTIVE CLASS - 1 I OBSERVED IN THE COMMON HALLS THE FAILURE TO PROVIDE GFCI OUTLETS AS REQUIRED BY LL39/2015 FOR OUTLETS BELOW 44" ACC... $4,000 $0 Jun 9, 2026
Feb 25, 2025 39139539N RESOLVE CLASS - 2 I OBSERVED IN THE ELEVATOR MOTOR ROOM THE USE OF THE DISCONNECT SWITCH AS A RACEWAY TO SUPPLY POWER TO A CIRCUIT BREA... $2,000 $0 Jun 9, 2026
Feb 25, 2025 39139537J RESOLVE CLASS - 2 I OBSERVED THE IMPROPER CROSSING OF LINE AND LOAD IN THE ELEVATOR SWITCH . THE PASSING OF LINE AND LOAD CONDUCTORS TH... $2,400 $0 Jun 9, 2026
Feb 25, 2025 39139538L RESOLVE CLASS - 1 UNLAWFUL ACTS: FAILURE TO COMPLY WITH COMMISSIONER'S ORDER AS STATED IN ECB# 39072206L ISSUED ON 10/18/2022 AND CORRE... $0 $0 May 6, 2025
Oct 18, 2022 39072210Y RESOLVE CLASS - 2 I OBSERVED IN THE BOILER AND ELEVATOR MACHINE ROOMS CONDUITS NOT SUPPORTED AS REQUIRED. PHOTOS TAKEN, PROPERLY SECURE... $0 $0 Dec 6, 2022
Oct 18, 2022 39072209R RESOLVE CLASS - 2 I OBSERVED IN THE ELEVATOR MOTOR ROOM THE USE OF THE MOTOR DISCONNECTS TO PASS BRANCH CIRCUIT WIRING NOT TERMINATED B... $0 $0 Dec 6, 2022
Oct 18, 2022 39072200K RESOLVE CLASS - 1 OBSERVED NEWLY INSTALLED GAS PIPING TO THREE NEW WATER HEATERS THAT ARE LOCATED IN THE BOILER ROOM THAT IS IN THE BAS... $2,500 $0 Apr 25, 2023
Oct 18, 2022 39072207N RESOLVE CLASS - 2 I OBSERVED IN THE MAIN ELECTRICAL ROOM THE BONDING OF TWO 400 AMP DISCONNECT SWITCHES AFTER SERVICE SWITCHES 1 & 2. N... $400 $0 Jan 24, 2023
Oct 18, 2022 39072208P RESOLVE CLASS - 2 I OBSERVED IN THE ELEVATOR, BOILER AND MAIN ELECTRICAL ROOM CONVENIENCE RECEPTACLES NOT OF THE GFCI TYPE OR GFCI PROT... $1,200 $0 Dec 6, 2022
Oct 18, 2022 39072206L RESOLVE CLASS - 1 I OBSERVED IN THE IN THE COMMON HALLS CONVENIENCE RECEPTACLES NOT OF THE TAMPER TYPE OR TAMPER RESISTANT AS REQUIRED ... $1,600 $0 Dec 6, 2022
May 31, 2022 39063145M RESOLVE CLASS - 1 I OBSERVED IN THE HALLWAYS CONVENIENCE RECEPTACLES NOT OF THE TAMPER RESISTANT/PROOF TYPE AS REQUIRED WHERE ACCESSIBL... $1,600 $0 Jul 19, 2022
May 31, 2022 39063142R RESOLVE CLASS - 2 AT FIRST FLOOR, MAIN ENTRANCE, METAL SHED WITH LOOSE, LOST, DETACHED PARTS THROUGHOUT THE ACCESS AREA TO THE BUILDING... $0 $0 Jul 19, 2022
Feb 9, 2022 39055826H RESOLVE CLASS - 2 BAROMETRIC DAMPER NOT WORKING,SOOT ON BURNER & BOILER,MISSING VENT LIMINATOR CLEAN OUT DOOR NOT CLOSING,CORRECT VIOLA... $0 $0 Mar 29, 2022
Feb 9, 2022 39055825X RESOLVE CLASS - 2 MISSING COVER FOR LOW WATER CUT OFF,MISSING VENT LIMINATOR,SOOT ON BOILER & BURNER CORRECT VIOLATION & SEND IN CERTIF... $0 $0 Mar 29, 2022
Feb 11, 2021 39036147M RESOLVE CLASS - 2 GLASS MISSING IN REAR OF BOILER TO SIGHT FIRE AND OIL LEAK AT COMPRESSOR $0 $0 Apr 27, 2021
Sep 22, 2020 39029024R RESOLVE CLASS - 1 NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... $1,250 $0 May 25, 2021
Sep 22, 2020 39029023P RESOLVE CLASS - 1 NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... $1,250 $0 May 25, 2021
Sep 22, 2020 39029022N RESOLVE CLASS - 1 NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... $1,250 $0 May 25, 2021
Feb 25, 2020 39018227N RESOLVE CLASS - 2 FOUND 1 FEDERAL FST 150 OIL FIRED HOT WATER BOILER. 1- MISSING THERMAL SPILL SWITCH. 2- UNUSED OPENING IN CHIMNEY. CO... $625 $0 Feb 2, 2021
Feb 25, 2020 39018226L RESOLVE CLASS - 2 FOUND 1 FEDERAL FST 150 OIL FIRED HOT WATER BIOLER. 1- MISSING THERMAL SPILL SWITCH. 2- DEFECTIVE SAIL SWITCH AT COMB... $312 $0 Feb 2, 2021
Feb 13, 2020 39017551K RESOLVE CLASS - 2 I OBSERVED IN FRONT STAIR B AND ROOM #129, AN EXIT LIGHT THAT IS BEING FED WITH HARDWIRED FLEXIBLE EXTENSION CORD, VI... $400 $0 Sep 15, 2020
Sep 30, 2019 35392797J RESOLVE CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION#35434213J ISSUED ON 07/01/19 AND TO FIL... $1,280 $0 Feb 18, 2020
Jul 1, 2019 35434212H RESOLVE CLASS - 2 FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED. OBSERVED IN CELLAR THE REMOVAL OF A UNION PLUMBING FITTING FRO... $0 $0 Nov 19, 2019
Jul 1, 2019 35434211X RESOLVE CLASS - 2 WORK W/O A PERMIT. OBSERVED IN CELLAR VIOLATING CONDITION OUTLINED IN SUMMONS#35415209N FOR PLUMBING UNION FITTING IL... $0 $0 Nov 19, 2019