60-20 56 Road, Queens
Queens • Block 02704 • Lot 0062 • Zip: 11378
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 3 days ago- Grand Central 45 min 28 walking, 17 riding
- Times Square 48 min 28 walking, 20 riding
- Penn Station 56 min 28 walking, 28 riding
- Union Square 56 min 28 walking, 28 riding
- Fulton Street 62 min 28 walking, 34 riding
- Downtown Brooklyn 70 min 28 walking, 42 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Railroad
Bus
Citi Bike
Activity
Sales, filings, permits and violations from every dataset, in one order.
2018
-
New Building
APPLICATION FILED TO SHOW THE UNDERPINNING DESIGN AND DETAILS.
-
Alteration Type III
BNP 07-186 - 25 LINEAR FT FRONTAGE, BUILDERS PAVEMENT PLAN FILING IN CONJUNCTION WITH APPLICATION #420464054.
2017
-
Alteration Type II
INSTALL NEW SPRINKLER SYSTEM IN A NEW 2 FAMILY RESIDENTIAL PROPERTY. FILED IN CONJUNCTION WITH JOB#420464054. NO CHAN...
2016
2015
2014
-
DOB violation Aug 21, 2014
C-CONSTRUCTION OTHER OPTIONAL
2013
-
CLASS - 2
SEC. BC 1704.1.1 "FULL SWO ISSUED PURSUANT TO 28-207.2 AND POSTED AT PREMISES." FAILURE TO FILE A SPECIAL INSPECTIONS...
-
CLASS - 1
FAILURE TO NOTIFY DOB W/I 24-48 HRS OF THE START OF EXCAVATION. NOTED:UPON INSPECTION FOUNDATION & UNDERPINNING COMPL...
-
CLASS - 2
FAILURE TO POST DOT PERMIT FOR STREET/SIDEWALK CLOSING. NOTED: UPON INSPECTION 20 (YRD) CONTAINER IN STREET FRONT OF ...
2012
-
CLASS - 2
SEC. 28-105.1 WORK W/O A PERMIT. EXPIRED PERMIT. CONSTRUCTION FENCE INPLACE AT JOB SITE UNDER FENCE PERMIT #420011196...
-
Demolition
2011
-
Alteration Type I
-
DOB violation Jan 28, 2011
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
-
DOB violation Jan 13, 2011
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
2010
-
CLASS - 2
WORK W/O A PERMIT.NOTED:CONCRETE UNDERPINNING HAS BEEN INSTALLED @ EXP.4 ADJOINING BLDG,APPROX.30FT. LONG X6FT. H8IGH...
-
CLASS - 2
BC1814.1 28-104.7.1 27-157 27-152 MISC VIOLATION FAILURE TO PREPARE AND PROVIDE ADEQUATE SITE SPECIFIC PLANS DETAILS ...
-
Alteration Type II
INSTALATION OF SPRINKLER SYSTEM. NO CHANGE TO BULK, EGRESS OR OCCUPANCY OF THE BUILDING. JOB FILED IN CONJUNCTION WIT...
2008
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.