| Apr 15, 2016 | 38241491H | RESOLVE | CLASS - 2 | 59U07,59E01. 59U07-PROVIDE BRAKE MAINTENANCE TAG AS PER A17.1-2003 AND NYC APPENDIX K 8.6.4.6 | $500 | $0 | May 31, 2016 |
| Oct 24, 2012 | 38223423R | RESOLVE | CLASS - 2 | 67L10,68M07,61T07. 67- PHONE IN CAB NOT WORKING. 68- NO MAINT. LOG IN MOTOR ROOM. 61- NEED COMPANY NAME & PHONE # ON ... | $250 | $0 | Dec 11, 2012 |
| Jul 31, 2009 | 38203319Z | RESOLVE | CLASS - 2 | 56Y13.56O2.44H8 | $0 | $0 | Sep 22, 2009 |
| Aug 19, 2008 | 38188574N | RESOLVE | CLASS - 3 | 98BB05.100BB05.44M08.52K11 | $0 | $0 | Oct 14, 2008 |
| Sep 12, 2007 | 32052185Z | RESOLVE | Non-Hazardous | 50,50A,B,C,D,E,F,G,H,I,32A.50-530C DISCHARGE PIPE MISSING.50A-22"SMOKE PIPE CLEANOUT NOT SEALED.50B-MISSING BRASS SYP... | $0 | $0 | Oct 30, 2007 |
| Sep 12, 2007 | 32052186K | RESOLVE | Non-Hazardous | 32A,50,50A,B,C.50-MISSING DISCHARGE PIPE ON 530C VALVE.50A-PRESSURE GAUGE MISSING BRASS SYPHON TUBE ALSO ROTTED.50B-D... | $0 | $0 | Oct 30, 2007 |
| Jul 10, 2007 | 38168176J | RESOLVE | Non-Hazardous | 17H11.27H11.38O02.55Y13.66O02.86B05.40T07.39L10.39L-MACHINE ROOM LIGHTING. | $350 | $0 | May 6, 2008 |
| May 8, 1998 | 38072989K | RESOLVE | Non-Hazardous | 46H50Y57O #46-REPLACE WORN ROPES. #50-REPLACE WORN MACHINE SEALS. | $0 | $0 | Jun 30, 1998 |
| Apr 22, 1997 | 34154129Y | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT WORK NOTED: INSTALLED AIR CONDITION SYSTEM SIDE OF BUILDING REMEDY: OBTAIN A PERMIT IF FEASIBLE... | $350 | $0 | Jul 8, 1997 |
| Mar 9, 1993 | 38032019N | RESOLVE | Non-Hazardous | 02L,01L,25I,901)CLEAN SYSTEM (25)REAJUST FOR PROPERTY LEASING OF REAR DOOR. | $0 | $0 | Apr 20, 1993 |
| Jul 20, 1992 | 38025525K | RESOLVE | Non-Hazardous | 10L,15M,18M,62L,62M,36E,36W, 10R.REPLACE BROKEN CAR STATION PLATE & OR REPAIR SAME BLOCK 4FL AND 5FL. BUTTON HOLES PR... | $100 | $0 | Sep 1, 1992 |
| Sep 23, 1991 | 38015136H | RESOLVE | Non-Hazardous | 73M #73 FAILURE TO PROVIDE FIREMAN SERVICE OPERATION AS PER SECTION 27-996.02 OF BUILDING CODE. | $150 | $0 | Nov 12, 1991 |
| Sep 13, 1991 | 38015127X | RESOLVE | Non-Hazardous | 16M,#(16) PROVIDE TWO GIBS ON ALL HOISTWAY DOORS; FIRST FLOOR MISSING. | $0 | $0 | Oct 29, 1991 |
| Jul 31, 1991 | 34054580K | RESOLVE | Non-Hazardous | FAILURE TO FILE A REPORT OF COMPLIANCE WITH LOCAL LAW 16/84 CERTIFYINGTO THE INSTALLATION OF REQUIRED FIRE PROTECTION... | $0 | $0 | Sep 17, 1991 |