Issued Violation Status Severity Description Penalty Balance due Hearing
Apr 5, 2024 35678608P RESOLVE CLASS - 2 EXIT DOOR NOT SELF-CLOSING. 1 FLOOR FRONT CLASS E, 2 FLOOR FRONT BACKDOOR CLASS A AND STAIRWELL ACROSS FROM CLASS A. ... $0 $0 Jun 11, 2024
Mar 18, 2019 35402121X RESOLVE CLASS - 2 EXIT DOOR NOT SELF CLOSING.NOTED:AT 2ND FLOOR EXIT DOOR NOT SELF CLOSING DUE TO HARDWARE MISSING. REPAIR.REPLACE DOOR. $0 $0 May 28, 2019
Mar 18, 2019 35402123J RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NO FIRE STOPPING PER BC 712.3;27-345.NOTED:AT CELLAR AT ELECTRI... $0 $0 May 28, 2019
Mar 18, 2019 35402124L RESOLVE CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EIXT PASSAGEWAY.NOTED:AT CELLAR LEVEL NEXT TO KITCHEN GOING TO FIRST FLOOR EXIT DOOR ... $1,250 $0 May 28, 2019
Mar 18, 2019 35402122H RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER.NOTED:AT CELLAR AT ELECTRICAL ROOM ILLEGAL STORAGE OF COMBUSTIB... $0 $0 May 28, 2019
Feb 18, 2015 35107985L RESOLVE CLASS - 2 WORK W/O PERMIT. NOTED: AN ILLUMINATED SIGN APPRX 24'X2'INSTALLED W/O PERMIT )AT FRONT "SHALOM LEARNING CENTER" RMDY:... $400 $0 Jul 14, 2015
Aug 3, 2014 35039126L RESOLVE CLASS - 2 ELECTRICAL WORK W/O PERMIT OBSERVED @ 12:35PM BRANCH WIRING,INSTALLED IN BSMT FOR 30 AMP FUSE CUT OUT FIRE ALARM CUT ... $0 $0 Sep 23, 2014
Jul 18, 2014 34973306P RESOLVE CLASS - 2 FAILURE TO COMPLY W/ THE COMMISSIONERS ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPT OF BLDGS FOR NOV#35091... $400 $0 Oct 7, 2014
May 27, 2014 35088504K RESOLVE CLASS - 1 PARTIAL STOP WORK ORDER FOR SUPPORTED SCAFFOLD ISSUED PURSUANT TO 28-207.2 & POSTED @ PREMISES.USERS CERT.NOTE:SUPPOR... $1,600 $0 Jul 15, 2014
May 27, 2014 35088506Y RESOLVE CLASS - 1 3314.8,PARTIAL STOP WORK ORDER FOR SUPPORTED SCAFFOLD ISSUED PURSUANT TO 28-207.2 & POSTED @ PREMISES.GUARDRAILS & TO... $1,600 $0 Jul 18, 2014
May 27, 2014 35088505M RESOLVE CLASS - 1 3314.5,PARTIAL STOP WORK ORDER FOR SUPPORTED SCAFFOLD ISSUED PURSUANT TO 28-207.2 & POSTED @ PREMISES.PLATFORM ON ALL... $1,600 $0 Jul 18, 2014
May 4, 2014 35091030P RESOLVE CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONST. OPERATIONS. NOTED: JOB SITE FENCE MISSING IN VARIOUS L... $800 -$4,000 Nov 14, 2014
May 4, 2014 35091029H RESOLVE CLASS - 2 WORK AFTER HOURS W/O VARIANCE PERMIT CONTRARY TO 28-105.12.5 NOTED: WORKING W/O A VARIANCE PERMIT DURING AFTER HOURS.... $800 $0 Sep 23, 2014
Jul 9, 2013 35022171J RESOLVE CLASS - 1 FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION NO HANDRAILS: NOTED AT STAIRWELL AT... $1,000 $0 Aug 27, 2013
Sep 4, 2012 34948878X RESOLVE CLASS - 2 1805.3 DESIGN FAILS TO CONSIDER THE INFLUENCE OF NEW FOOTING ON ADJOINING FOOTINGS AT DIFFERENT ELEVATION.PLANS FAILE... $0 $0 Oct 23, 2012
Sep 4, 2012 34948879H RESOLVE CLASS - 1 3304.7 FAILURE TO PROVIDE ADEQUATE MEANS OF EXIT FORM EXCAVATION IN 6'DEEP EXCAVATION NO EGRESS AT ANY EXPOSURE EXIST... $1,600 $0 Oct 23, 2012
Aug 31, 2012 34951664H RESOLVE CLASS - 2 FAILURE TO PROVIDE PROTECTION OF EXCAVATION NOTED ON ACTIVE JOBSITE SHORING PILES BEING INSTALLED EXCAVATION DEPTH IS... $0 $0 Oct 16, 2012
Sep 26, 2011 34923362Y RESOLVE CLASS - 2 JOB SITE FENCE NOT CONSTRUCTED PURSUANT TO SUBSECTION.@ THE TIME OF MY INSPEC.IN AN ACTIVE CONST.APPROX 4 WORKERS ON ... $800 $0 Jan 10, 2012
Sep 26, 2011 34923361M RESOLVE CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY DEMOLITION OPERATIONS.@ THE TIME OF MY INSPEC.APPROX 4 WORKER... $2,400 $0 Jan 10, 2012
Sep 26, 2011 34923360K RESOLVE CLASS - 1 WORK W/O A PERMIT.MECHANICAL DEMO PERMIT. @ THE TIME OF MY INSPEC.APPROX.4 WORKERS ON SITE.I OBSERVED MECHANICAL DEMO... $1,600 $0 Jan 10, 2012