Maintenance code violations
482 Onderdonk Avenue, Queens • Block 03431 • Lot 0035
100 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| May 7, 2026 | A | NOV SENT OUT | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... | — | Aug 10, 2026 |
| Dec 9, 2025 | C | NOV SENT OUT | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1R, 1st STORY, ... | 1R | Dec 9, 2025 |
| Dec 9, 2025 | C | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL... | — | Dec 23, 2025 |
| Jun 12, 2025 | A | VIOLATION DISMISSED | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... | — | Sep 15, 2025 |
| Apr 16, 2024 | A | VIOLATION DISMISSED | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... | — | Jul 20, 2024 |
| Mar 29, 2023 | A | VIOLATION DISMISSED | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... | — | Jul 2, 2023 |
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| Mar 4, 2022 | A | VIOLATION DISMISSED | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... | — | Jun 7, 2022 |
| Apr 16, 2021 | A | VIOLATION DISMISSED | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... | — | Jul 20, 2021 |
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| — | I | VIOLATION DISMISSED | SECTION27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CO... | — | — |
| Jun 22, 2015 | A | VIOLATION CLOSED | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE ... | — | Sep 25, 2015 |
| Jun 22, 2015 | A | VIOLATION CLOSED | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR... | — | Sep 25, 2015 |
| Jun 22, 2015 | A | VIOLATION CLOSED | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COM... | — | Sep 25, 2015 |
| Jun 22, 2015 | A | VIOLATION CLOSED | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR... | — | Sep 25, 2015 |
| Jun 22, 2015 | C | VIOLATION CLOSED | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIG... | — | Jun 30, 2015 |
| Jun 22, 2015 | B | VIOLATION CLOSED | § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANC... | 2R | Jul 27, 2015 |
| Jun 22, 2015 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY | 2R | Jul 27, 2015 |
| Jun 8, 2015 | B | VIOLATION CLOSED | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF BEDBUGS IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY,... | 3L | Jul 13, 2015 |
| — | I | VIOLATION DISMISSED | SECTION27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CO... | — | — |
| Sep 11, 2014 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 2R | Oct 16, 2014 |
| Sep 11, 2014 | B | VIOLATION CLOSED | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF BEDBUGS IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY,... | 2R | Oct 16, 2014 |
| Sep 11, 2014 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY,... | 2R | Oct 16, 2014 |
| Apr 30, 2014 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BASE CABINET IN THE KITCHEN LOCATED AT APT 2R, 2nd STORY, ... | 2R | Jun 4, 2014 |
| Apr 30, 2014 | B | VIOLATION CLOSED | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM WEST... | 2R | Jun 4, 2014 |
| Apr 30, 2014 | B | VIOLATION CLOSED | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM WEST AT... | 2R | Jun 4, 2014 |
| Apr 30, 2014 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM WEST... | 2R | Jun 4, 2014 |
| Apr 30, 2014 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). , LOCATED AT APT 2R, 2nd STORY, 1st APART... | 2R | Jun 4, 2014 |
| Apr 30, 2014 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE FAUCET AT WASH BASIN IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY,... | 2R | Jun 4, 2014 |
| Apr 30, 2014 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REFIT THR DOOR IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | 2R | Aug 3, 2014 |
| Oct 1, 2012 | A | VIOLATION CLOSED | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR... | — | Jan 4, 2013 |
| Oct 1, 2012 | A | VIOLATION DISMISSED | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COM... | — | Jan 4, 2013 |
| Oct 1, 2012 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY,... | 3R | Nov 5, 2012 |
| Oct 1, 2012 | B | VIOLATION CLOSED | § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANC... | 3R | Nov 5, 2012 |
| Oct 1, 2012 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES... | — | Nov 5, 2012 |
| Oct 1, 2012 | A | NOT COMPLIED WITH | § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL... | — | Jan 4, 2013 |
| Sep 20, 2012 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY,... | 3R | Oct 25, 2012 |
| Sep 20, 2012 | B | VIOLATION CLOSED | § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANC... | 3R | Oct 25, 2012 |
| Sep 12, 2012 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE DOOR LOCK IN THE ENTRANCE LOCATED AT APT 3R, 3rd STORY, 1s... | 3R | Oct 17, 2012 |
| Sep 12, 2012 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY,... | 3R | Oct 17, 2012 |
| Sep 12, 2012 | B | VIOLATION CLOSED | § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANC... | 3R | Oct 17, 2012 |
| Sep 12, 2012 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE AT WEST WALL IN THE BAT... | 3R | Oct 17, 2012 |
| Sep 12, 2012 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE BATHROOM LOCATED AT APT 3R... | 3R | Oct 17, 2012 |
| Sep 4, 2012 | B | VIOLATION CLOSED | § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANC... | 2R | Oct 9, 2012 |
| Sep 4, 2012 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1L, 1st STORY,... | 1L | Oct 9, 2012 |
| Sep 4, 2012 | B | VIOLATION CLOSED | § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANC... | 1L | Oct 9, 2012 |
| Sep 4, 2012 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY,... | 2R | Oct 9, 2012 |
| May 17, 2012 | B | VIOLATION CLOSED | § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANC... | 2R | Jun 21, 2012 |
| May 17, 2012 | B | VIOLATION CLOSED | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY,... | 2R | Jun 21, 2012 |