1626 Cody Avenue, Queens
Queens • Block 03557 • Lot 0028 • Zip: 11385
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 5 days ago- Union Square 36 min 3 walking, 33 riding
- Fulton Street 40 min 3 walking, 37 riding
- Downtown Brooklyn 44 min 3 walking, 41 riding
- Grand Central 47 min 3 walking, 44 riding
- Times Square 48 min 3 walking, 45 riding
- Penn Station 50 min 3 walking, 47 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Railroad
Bus
Citi Bike
Places nearby
Pierogi Boys
No description yet
They Say That
No description yet
Ilegal Taqueria
No description yet
Nhà Minh
No description yet
Joe & John's Pizzeria
Joe & John's Pizzeria is a cozy neighborhood spot serving up delicious, authentic New York-style pizza. With a casual...
Evil Twin Brewing NYC
No description yet
Luther’s at TV Eye
No description yet
Peg's Cavalier
Step into Peg's Cavalier for a cozy and inviting atmosphere, serving up delicious cocktails and a variety of craft be...
Activity
Sales, filings, permits and violations from every dataset, in one order.
2026
-
CLASS - 2
REPLACE JUMPED FUSE. REPROGRAM IN CAR EMERGENCY COMMUNICATION.
2024
-
DOB violation Aug 2, 2024
BENCH-FAILURE TO BENCHMARK NONE
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
-
DOB violation May 2, 2024
BENCH-FAILURE TO BENCHMARK NONE
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
2023
-
DOB violation Jun 30, 2023
HBLVIO-HIGH PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL HGH PRESSURE INSPECTION
-
DOB violation Jun 30, 2023
HBLVIO-HIGH PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2020 INTERNAL HGH PRESSURE INSPECTION
-
DOB violation Jun 30, 2023
HBLVIO-HIGH PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL HGH PRESSURE INSPECTION
-
DOB violation Jun 30, 2023
HBLVIO-HIGH PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL HGH PRESSURE INSPECTION
2022
-
Alteration Type II
REMOVAL OF THREE (3) NATURAL GAS BOILERS AND ONE (1) DOMESTIC HOT WATER HEATER FROM SECOND (2ND) FLOOR. NO CHANGE IN ...
2021
2020
2017
2010
-
CLASS - 2
FAILURE TO MAINTAIN BLDG WALL(S) OR APPURTENANCES - NOTED THERE EXISTSVERTICAL AND HORIZONTAL CRACKS AT FRONT FACADE....
2009
-
Alteration Type II
SUBSEQUENT DOCUMENT FILED FOR STRUCTURAL WORK AS PER PLANS SUBMITTED.
2008
-
CLASS - 3
100M05,52Q03.100M05-MISSING 2 YR TEST TAG. PERFORM THE TEST.52Q03-INSTALL CABLE GUARDS ON HOIST MACHINE.
-
Alteration Type I
Construction of 3rd flr. Installation of partitions and doors. Vertical enlargement only to create new caretakers apa...
2007
-
Non-Hazardous
50A.FULTON VT BOILER,15HP,NB 73581,GAS,1995.50A-HIGH PRESSURE STEAM BOILER IN OPERATION ON OPEN FACTORY FLOOR W/NO EN...
-
Non-Hazardous
50A,B.FULTON VT BOILER,15HP,NB 85936,GAS 2000.50A-BOILER INSTALLATION COVERED BY(WALL)PERMIT #401849318-01.RESPONDENT...
-
Alteration Type II
INSTALL GAS FIRED HIGH PRESSURE BOILER. CONNECT TO EXISTING HIGH PRESSUR E STEAM PIPING. NO CHANGE IN EGRESS, USE OR ...
2005
-
Alteration Type II
Application filed for installation of mechanical equipment as shown on plans. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
2003
-
Non-Hazardous
24B/32A/34A/38/50A/50B. CYCLOTHERN FTSM BOILER, HP STEAM OIL FIRED NB 12698 (50A) NO DISCHARGE PIPE ON THE SAFETY VAL...
2002
-
Alteration Type II
AT 2ND FLOOR (NORTH END) INDUSTRIAL BLDG . INSTALL MASONRY PARTITIONS & OORS FOR ACCESSORY OFFICES INCLUDING GAS ...
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Building Permits
Owner information from Department of Buildings filings
Recent Building Permits
Owner information from recent DOB NOW filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records