Issued Violation Status Severity Description Penalty Balance due Hearing
Aug 26, 2024 37029058M RESOLVE CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS #39053467X ISSUED ON 12/23/2021, AND FAILURE TO FILE... $625 $0 Jun 10, 2025
Aug 26, 2024 37029057K ACTIVE CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS #39053466Y ISSUED ON 12/23/2021, AND FAILURE TO FILE... $625 $0 Jun 10, 2025
Mar 19, 2024 37027143H RESOLVE CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS #39037338J ISSUED ON 3/9/2021, AND FAILURE TO FILE A... $3,125 $0 Sep 23, 2024
Mar 19, 2024 37027144J RESOLVE CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS #39037339L ISSUED ON 3/9/2021, AND FAILURE TO FILE A... $3,125 $0 Sep 23, 2024
Mar 19, 2024 37027138N RESOLVE CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS #39036596H ISSUED ON 2/23/2021, AND FAILURE TO FILE ... $3,125 $0 Sep 23, 2024
Dec 23, 2021 39053466Y RESOLVE CLASS - 2 SEAL ABOVE DOOR TO BOILER ROOM,SEAL BAS OF CHIMNEY,HARTFORD LOOP & PIPING NEED TO BE REPLACED,COMBUSTION AIR TERMINAT... $625 $0 May 10, 2022
Dec 23, 2021 39053467X RESOLVE CLASS - 2 COMBUSTION AIR TERMINATION NOT 30"HIGH $625 $0 May 10, 2022
Dec 23, 2021 39053468H RESOLVE CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH D.O.B. FOR VIOLATION #039036... $0 $0 Jun 7, 2022
Mar 9, 2021 39037338J ACTIVE CLASS - 2 PIGTAIL ON MANUAL RESET PRESSURETROL MISSING, CORRECT ALL VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION $625 $0 Apr 27, 2021
Mar 9, 2021 39037339L ACTIVE CLASS - 2 FOUND NEW YORKER GAS FIRED BOILER MODEL# CGS80 SERIAL# 64697498 NOT REGISTERED REGISTER THE BOILER AND CORRECT ALL VI... $625 $0 Apr 27, 2021
Feb 23, 2021 39036596H ACTIVE CLASS - 2 BOILER UNREGISTERED LEAK ON RETURN GAGL LEAKING MISSING PIGTAILS ON PRESTRLS REL.VLV TO BE VERTICAL WITH DISCHG HOLES... $625 $0 Apr 13, 2021
May 21, 2019 37015046H RESOLVE CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLA ION#35315797K ISSUED ON 08/06/2018 AND TO FILE ... $625 $0 Sep 24, 2019
Aug 6, 2018 35315797K RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.I OBSERVED IN CELLAR AREA A BROKEN PIPE SPRAYING WATER ALL OVER... $625 $0 Sep 25, 2018
Jun 6, 2018 35315799Y ACTIVE CLASS - 1 WORK WITHOUT A PERMIT.I OBSERVED ON THE 1ST FLOOR AREA OF QUAN IHEN LAUNDROMET 12 ADDITIONAL COMMERCIAL DRYERS WERE I... $1,600 $0 Nov 20, 2018
Oct 1, 2008 34703631Z RESOLVE CLASS - 2 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS FOR ALT 2 JOB#402025027 PERMIT EXP 2/9/06. CONTRARY: PLAN DO... $2,500 $0 Nov 25, 2008
Jun 19, 2008 34654117H RESOLVE Non-Hazardous WORK CONTRARY TO APPROVED PLANS FOR ALT II JOB #402420563 PERMIT HAS EXPIRED ON 5/17/07 CONTRARY FOUND ADA TOILET DOE... $2,500 $0 Aug 12, 2008
Jun 19, 2008 34654118J RESOLVE Non-Hazardous EXIT DOOR SWINGS AGAINST THE FLOOR OF EGRESS. FOR ALT II JOB #402420563 OF WHICH PERMIT HAS EXPIRED@ 05/17/07. LAUNDR... $2,500 $0 Aug 12, 2008
May 20, 2005 32048175N RESOLVE Non-Hazardous B4A/BQ9/36/32A/38/50A/50B/50C 50A-EXPSOED WOOD BEAMS IN BOILER ROOM 50B-HOLES IN BOILERS ROOM CEILING AND WORK 50C SE... $0 $0 Aug 2, 2005
May 20, 2005 32048176P RESOLVE Non-Hazardous B4A/19B/25A/25B/50A/50B (50A)BACK FLOW PREVENTOR MISSING (50B)COIL PLATE LEAKING (50C)PIPE PIPE SAFTEY OR RELIEF VALV... $0 $0 Aug 2, 2005
Feb 7, 2005 34464637Y RESOLVE Non-Hazardous WORK DOES NOT CONFORM TO APPROVED PLANS.PERMITS & PLANS #401953427.AT REAR OF 123-17 18 AVE THREE PIECED BATHROOM INS... $130 $0 Mar 29, 2005
Oct 15, 2004 32045960P RESOLVE Non-Hazardous BQ9 36 BQ9-INSTALLING NEW BOILER AND HOT WATER HEATER WITHOUT WORK PERMITS ISSUED. $0 $0 Nov 30, 2004
May 14, 2004 34433881Y RESOLVE Hazardous FAILURE TO MAINTAIN BLDG.- NOTE: 1) MORE THAN 20 CUBIC YRDS OF FLAMMABLE CONSTRUCTION DEBRIS, OLD LUMBER, WOOD LATH A... $2,500 $0 Jan 25, 2005
May 4, 2004 34437713N RESOLVE Non-Hazardous ILLEGAL OCCUPANCY OF BLDG. OCCUPANCY CONTRARY TO THAT ALLOWED BY THE DEPT OF BLDG RECORDS. ILLEGAL OCCUPANCY NOTED: A... $2,500 $0 Jan 25, 2005
May 4, 2004 34437709K RESOLVE Hazardous WORK WITHOUT A PEMRIT WORK NOTED AT 1ST FLOOR REMOVED INTERIOR PARTITIONS/ FRAMING AND ERECTED NEW PARTITIONS TO SUBD... $0 $0 Oct 5, 2004
May 4, 2004 34437710H RESOLVE Non-Hazardous WORK WITHOUT A PEMRIT WORK NOTED AT 1ST FLOOR APT 1R DROP CEILING INSTALLED WITH TIE WIRE (SHOULD BE BLACK IRON PENCI... $0 $0 Oct 5, 2004
May 4, 2004 34437711J RESOLVE Hazardous FAILURE TO PROPERLY AND SAFELY REMOVE DEBRIS FROM CONSTRUCTION SITE NOTED 1ST FLOOR GUTTED AND AT FRONT STORAGE OF PI... $0 $0 Oct 5, 2004
May 4, 2004 34437712L RESOLVE Non-Hazardous FAILURE TRO MAINTAIN NOTED REAR HALLWAY CEILING IN DISREPAIR HOLES IN CEILING REMEDY:MAINTAIN PREMISES MAKE NECESSARY... $0 $0 Oct 5, 2004
May 3, 2004 34420209N RESOLVE Non-Hazardous WORK WITHOUT A PERMIT NOTED REMOVED WALLS AT 1ST FLOOR AND PILED CONSTRUCTION DEBRIS IN FRONT STORE ERECTED PARTITION... $250 $0 Jun 22, 2004
May 3, 2004 34420208L RESOLVE Non-Hazardous WORK WITHOUT A PEMRIT WORK NOTED REMOVED WALLS AT 1ST AND 2ND FLS ERECTED NEW PARTITION AT 1ST & 2ND FLS CREATING APA... $250 $0 Jun 22, 2004