ECB violations
23-48 122 Street, Queens • Block 04225 • Lot 0041
13 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Dec 2, 2022 | 35670105R | RESOLVE | CLASS - 2 | TEMP CONSTRUCTION EQUIPMENT ONSITE:EXPIRED PERMIT.AS NOTED:ATOI CONSTRUCTION CLOSED.OBSERVED CONSTRUCTION PLYWOOD FEN... | $0 | $0 | Mar 7, 2023 |
| Nov 19, 2019 | 35444759K | RESOLVE | CLASS - 2 | JOB SITE PLYWOOD CONSTRUCTION FENCE NOT PURSUANT TO SECTION. AS NOTED:AT TIME OF INSPECTION CONSTRUCTION SITE WAS NOT... | $500 | $0 | Dec 8, 2020 |
| Aug 9, 2019 | 35441181J | RESOLVE | CLASS - 2 | JOB SITE FENCE NOT CONSTRUCTED OR MAINTAINED TO CODE. NOTES: AT THE TIME OF MY INSPECTION OF AN PERMITTED NEW BLDG SI... | $0 | $0 | Oct 15, 2019 |
| Jul 10, 2019 | 37015425H | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#35368632L ISSUED ON 10/19/18,AND TO FILE A... | $3,125 | $0 | Feb 11, 2020 |
| Jul 10, 2019 | 37015426J | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#35368633N ISSUED ON 10/19/18, AND TO F... | $1,250 | $0 | Feb 11, 2020 |
| Oct 19, 2018 | 35368633N | RESOLVE | CLASS - 2 | BC3301.7 FAILURE TO PROVIDE PE APPROVED DESIGN DRAWINGS. AS NOTED: AT TIME OF INSPECTION AN ACTIVE CONSTRUCTION SITE.... | $1,250 | $0 | Dec 11, 2018 |
| Oct 19, 2018 | 35368632L | RESOLVE | CLASS - 2 | BC3301.7 FAILURE TO PROVIDE RE APPROVED DESIGN DRAWINGS. AS NOTED: AT TIME OF INSPECTION AN ACTIVE CONSTRUCTION SITE.... | $1,250 | $0 | Dec 11, 2018 |
| Aug 31, 2018 | 35319353H | RESOLVE | CLASS - 2 | WORK WITHOUT A PERMIT(NEW BUILDING PERMIT EXPIRED)AS NOTED:AT TIME OF INSPECTION AN ACTIVE CONSTRUCTION SITE.OBSERVED... | $0 | $0 | Oct 16, 2018 |
| Jun 11, 2018 | 35332221M | RESOLVE | CLASS - 2 | BC3307.7 JOB SITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBSECTION. AT TIME OF INSPECTION, OBSERVED A CONST... | $1,250 | $0 | Jan 15, 2019 |
| Jun 11, 2018 | 35332220K | RESOLVE | CLASS - 1 | BC3301.2 NO OVERHEAD PROTECTION. AT TIME OF INSPECTION OBSERVED A CONSTRUCTION SITE WITH STEEL FRAMING WAS ON PROGRES... | $2,500 | $0 | Jan 15, 2019 |
| May 22, 2018 | 35273505R | RESOLVE | CLASS - 1 | BC1704.4/1RCNY 101.06. FAILURE TO PROVIDE SPECIAL INSPECTION DURING GROUTING. AS NOTED: AT TIME OF MY INSPECTION 2ND ... | $2,500 | $0 | Dec 18, 2018 |
| May 22, 2018 | 35273504P | RESOLVE | CLASS - 1 | UNSAFE STORAGE OF MATERIALS DURING CONTRUCTION OR DEMO. AS NOTED: AT TIME OF INSPECTIONS, ACTIVE SITE 2ND FLOOR WORKI... | $6,250 | $0 | Sep 4, 2018 |
| Apr 12, 2017 | 35224717H | RESOLVE | CLASS - 1 | 3303.4.1.1 MAINTENANCE OF PEDESTRIAN SIDEWALK TRIPPING HAZARD.AT TIME OF INSPECTION NOTED:AT EXPO #1 OF JOB SITE GATE... | $1,600 | $0 | Aug 22, 2017 |