ECB violations

31 Drive, Queens • Block 04413 • Lot 0020

81 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
May 26, 2009 34779354K RESOLVE CLASS - 2 REISSUE: 34645797X EXTERIOR BRICK FACADE ON THE 2ND FLOOR LEVEL IS CRACKED & BULGING ON THE WEST/SOUTH SIDE OF THE SO... $0 $0 Jul 7, 2009
Jun 25, 2008 34645799J RESOLVE Hazardous FOUNDATION WALL HAS BECOME POROUS AND ALLOWING RAIN WATER INTO BUILDING CAUSING INTERIOR DAMAGE ON CELLAR LEVEL. REME... $0 $0 Sep 9, 2008
Jun 25, 2008 34645798H RESOLVE Hazardous REISSUE: 34482083K PLASTER ON THE WALL & CEILING IS SPALLING LOCATED IN THE AUDITORIUM 1ST FLR. REMEDY: REPAIR PLASTER. $0 $0 Sep 9, 2008
Jun 25, 2008 34645797X RESOLVE Hazardous REISSUE: 34586791H BRICK FACADE IS BUILDING ON THE WEST SIDE 2ND FLR. REMEDY: REPAIR/REPLACE BRICK FACADE $0 $0 Sep 9, 2008
Jun 29, 2007 34586792J RESOLVE Hazardous REISSUE:34513482R A VERTICAL CRACKS IN THE WALL LOCATED IN RM 202 & 208 & 300 ON THE 3RD FL.APPROX 10FT LONG.REMEDY:R... $0 $0 Aug 14, 2007
Jun 29, 2007 34586791H RESOLVE Hazardous REISSUE:34513480N EXTERIOR BRICK IS MISSING MORTAR JOINT BETWEEN BRICK & IS BULGING OUT LOCATED BETWEEN EAST/WEST FAC... $0 $0 Aug 14, 2007
Jun 29, 2007 34586790X RESOLVE Hazardous REISSUE:34513481P A VERTICAL CRACK IN THE BLOCK WALL LOCATED AT EXIT 2 & 3 BETWEEN FLS 2 & 3 ADJACENT TO THE WINDOW.R... $0 $0 Aug 14, 2007
Jun 29, 2007 34586793L RESOLVE Hazardous REISSUE:34513481P EXTERIOR BULKHEAD HAS BECOME POROUS & ALLOWING RAIN WATER INSIDE CAUSING DAMAGES.REMEDY:WATER-PROOF... $0 $0 Aug 14, 2007
Mar 15, 2006 34513482R RESOLVE Hazardous REISSUE VI#34482082Z VI#34308444N FOR GYM STRUCTURAL CRACK ON COLUMN NEXT TO WINDOW.REISSUE VI#34374915X FOR CRACK IN... $0 $0 Jun 6, 2006
Mar 15, 2006 34513480N RESOLVE Hazardous REISSUE#34482087H.CRACKS IN BRICK WORK W/MISSING MORTAR JOINT AND CAULKING.FAILURE TO MAINTAIN INTERIOR OF BUILDING L... $0 $0 Jun 6, 2006
Mar 15, 2006 34513481P RESOLVE Hazardous REISSUE VI#34482083K WATER PENETRATION THROUGH EXTERIOR WALL/ROOF LOCATION BULKHEAD #2/3 (ROOFLEVEL)AUDITORIUM CEILIN... $0 $0 Jun 6, 2006
May 13, 2005 34482083K RESOLVE Hazardous WATER PENETRATION THROUGH EXTERIOR WALLS/ROOF.LOCATION:BULKHEAD #2/3 (ROOF LEVEL) AUDITORIUM,CEILING BASEMENT,NORTH W... $0 $0 Aug 2, 2005
May 13, 2005 34482084M RESOLVE Non-Hazardous SPALLING PLASTER & CRACKS IN PLASTER.LOCATION:AUDITORIUM CEILING.STAIR #5/6 3RD FLOOR TO ROOF BULKHEAD.REMEDY:REPAIR ... $0 $0 Aug 2, 2005
May 13, 2005 34482087H RESOLVE Non-Hazardous CRACKS IN BRICKWORK WITH MISSING MORTAR & CAULKING & BULGING.LOCATIONS:WEST FACADE:2ND FL ROOF @ NORTH & SOUTH ENDS N... $0 $0 Aug 2, 2005
Jan 29, 2003 34374923X RESOLVE Non-Hazardous FAILURE TO MAINTAIN. NOTED: IN GYM. HORIZONTAL STRUCTURAL CRACKS IN CONLUMS AT WINDOWS. REMEDY: MAKE ALL NECESSARY RE... $0 $0 Apr 15, 2003
Jan 29, 2003 34374916H RESOLVE Non-Hazardous FAILURE TO MAINTAIN. NOTED: IN ROOM 300 ONBOTH EAST AND WEST WALLS VERTICAL STRUCTURAL CRACK RUNS ENTIRE LENGTH OF BO... $0 $0 Apr 15, 2003
Jan 29, 2003 34374918L RESOLVE Non-Hazardous FAILURE TO MAINTAIN. NOTED: IN ROOM 202 TEN FOOT VERTICAL CRACK AT FRONT (BLACKBOARD) WALL. STRUCTURAL CRACK. REMEDY:... $0 $0 Apr 15, 2003
Jan 29, 2003 34374920K RESOLVE Non-Hazardous FAILURE TO MAINTAIN. NOTED: IN ROOM 208 STRUCTURAL CRACK ON COLUMN BY WINDOW. REMEDY: MAKE ALL NECESSARY REPAIRS. $2,500 $0 Apr 15, 2003
Jan 29, 2003 34374915X RESOLVE Non-Hazardous FAILURE TO MAINTAIN NOTED: IN EXIT #5 BETWEEN ROOF AND THIRED FLOOR SPALLING CONCRETE ON CEILING AND VERTICAL STRUCTU... $0 $0 Apr 8, 2003
Jan 29, 2003 34374924H RESOLVE Hazardous EXIT PASSAGEWAY OR CORRIDOR: TOTAL OBSTRUTION. NOTED: AT REAR EGRESS IN AUDITORIUM PASSAGEWAY TOTALLY OBSTRUCTED BY T... $2,500 $0 Apr 15, 2003
Jan 29, 2003 34374919N RESOLVE Non-Hazardous FAILURE TO MAINTAIN. NOTED: IN ROOM 204 TWO SIX FT. STRUCTURAL CRACKS ON CEILING. REMEDY: MAKE ALL NECESSARY REPAIRS. $0 $0 Apr 15, 2003
Jan 29, 2003 34374921M RESOLVE Non-Hazardous FAILURE TO MAINTAIN. NOTED: IN ROOM 218 MAJOR STRUCTURAL CRACK AT REAR OF CLASSROOM. CRACK RUNS FROM LENGTH OF REAR W... $0 $0 Apr 15, 2003
Jan 28, 2003 34374917J RESOLVE Non-Hazardous FAILURE TO MAINTIAN. NOTED: AT EXITS TWO AND THREE BETWEEN 2ND AND 3RD FLOORS. EIGHT FOOT VERTICAL STRUCTURAL CRACK A... $0 $0 Apr 15, 2003
Jan 22, 2002 34308443L RESOLVE Hazardous FAILURE TO MAINTAIN BUILDING. DEFECT IS STRUCTURAL CRACKS ON WALLS AT ROOMS #B10, B11 AND STAIR #11 AT BASEMENT. REME... $0 $0 Apr 9, 2002
Jan 22, 2002 34308444N RESOLVE Hazardous FAILURE TO MAINTAIN BUILDING. DEFECT IS STRUCTURAL CRACK ON LAST WALL IN GYMNASIUM. REMEDY: MAKE ALL REPAIRS. $0 $0 Apr 9, 2002
Jan 30, 2001 34257218H RESOLVE Hazardous FAILURE TO MAINTAIN BUILDING NOTED DEFECTS GROUNDWATER FLOODING CLASSROOMS.B1 AND B2 AND CORRIDOR HALLWAY,APPROX.1-2"... $0 $0 Apr 24, 2001
Jan 30, 2001 34257221Z RESOLVE Non-Hazardous FAILURE TO MAINTAIN BUILDING NOTED:DEFECTS DEFECTIVE WINDOWS THROUGHOUT ENTIRE SCHOOL BUILDINGS SOME ARE TAPED SHUT S... $0 $0 Apr 24, 2001
Jan 30, 2001 34257220R RESOLVE Hazardous FAILURE TO MAINTAIN BUILDING NOTED DEFECTS EXTERIOR WALLS OF ROOM 13 7LOCATED IN BASEMENT ARE SEVERLY CRACKED AND SEP... $0 $0 Apr 24, 2001
Jan 30, 2001 34257219J RESOLVE Hazardous FAILURE TO MAINTAIN BUILDING NOTED DEFECTS.MAIN ENTRANCE WAY FROM BASEMENT(STAIRWELL#11 HAS CRACKS AROUND DOOR.CORRID... $0 $0 Apr 24, 2001
Apr 14, 2000 34240617Y RESOLVE Non-Hazardous FAILURE TO MAINTAIN DEFECT IS:(A)DEFECTIVE WINDOWS THROUGHOUT THE BLDGNAILED SHUT ETC./INOPERABLE(B)WATER PENETRATION... $0 $0 Jun 13, 2000
Apr 5, 1999 34198649M RESOLVE Hazardous FIALURE TO MAINTAIN BLDG. INTERIRO. NOTED: NOT ALL WINDOWS OPERABLE: WINDOWS NAILED SHUT TO AVOID FURTHER HAZARD. REM... $0 $0 May 25, 1999