ECB violations
136-45 35 Avenue, Queens • Block 04951 • Lot 0069
17 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jan 20, 2010 | 34821085H | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN EGRESS CLEAR AND UNOBSTRUCTED. STAIRWELL PARTIALLYOBSTRUCTED AS FOLLOWS: AT 1ST TO CELLAR FOUND A... | $4,000 | $0 | Jan 12, 2016 |
| Jul 14, 2006 | 34529871R | RESOLVE | Non-Hazardous | RESIDENCE ALTERED FOR OCCUPANCY AS A DWELLING FOR MORE THAN THE LEGALLY APPROVED # OF FAMILIES.DOB RECORDS INDICATES ... | $0 | $0 | Sep 5, 2006 |
| May 18, 2006 | 34522489Y | RESOLVE | Hazardous | RESIDENCE ALTERED FOR OCCUPANCY AS A DWELLING, FOR MORE THAN THE LEGALLY APPROVED # OF FAMILIES. D.O.B. RECORDS C OF ... | $0 | $0 | Jul 25, 2006 |
| May 18, 2006 | 34522490L | RESOLVE | Hazardous | WORK WITHOUT PERMIT. WORK NOTED: AT FRIST FLOOR LEVEL, ERECTED FULL HEIGHT PARTITIONS.INSTALLED WATER AND WASTE LINES... | $0 | $0 | Jul 25, 2006 |
| Oct 28, 2002 | 34391407Y | ACTIVE | Non-Hazardous | 1 HR FIRE RATED WALL AT BOILER ENCLOSURE IS PENETRATED BY UNRATED CLOTHES DRRYER FL REMEDY: PROVIDE RATED FL OR REMOV... | $480 | $0 | Mar 11, 2004 |
| Oct 28, 2002 | 34391418J | ACTIVE | Non-Hazardous | INTERIOR STAIR AND ROOF BULKHEAD NOT PROVIDED IN 4 FAMILY DWELLING. REMEDY: PROVIDE BULKHEAD AND STAIR. | $400 | $0 | Mar 10, 2004 |
| Oct 28, 2002 | 34391436N | ACTIVE | Non-Hazardous | BOILER FLUE NOT CARRIED MINIMUM OF 3 FEET ABOVE ROOF PARAPET WALL. REMEDY: EXTEND BOILER FLUE. | $400 | $0 | Mar 11, 2004 |
| Oct 28, 2002 | 34391444N | ACTIVE | Non-Hazardous | FAILURE TO PROVIDE REQUIRED VENTED GLASS SKYLIGHT WITH WIRE GRATING ABOVE AND BELOW. REMEMDY: PROVIDE REQIRED SKYLIGH... | $480 | $0 | Mar 11, 2004 |
| Oct 28, 2002 | 34391454R | ACTIVE | Non-Hazardous | CELLAR STAIR NOT ENCLOSED IN FIRE RATED PARTITIONS REMEDY: PROVIDE STAIR ENCLOSORE AND FPSC DOORS AT TOP AND BOTTOM | $400 | $0 | Mar 11, 2004 |
| Oct 28, 2002 | 34391465M | ACTIVE | Non-Hazardous | APARTMENT DOOR OPENS DIRECTLY INTO STAIR ENCLOSURE NOT PERMITTED IN BOILING OVER THREE STORIES REMEDY: PROVIDE VESTILBE | $400 | $0 | Mar 11, 2004 |
| Oct 28, 2002 | 34391506J | ACTIVE | Non-Hazardous | ROOF DECK IS PLYWOOD AND DOES NOT MEET REQUIREMENTS FOR CLASS I NON COMBUSTIBLE CONSTRUCTION | $400 | $0 | Mar 11, 2004 |
| Oct 28, 2002 | 34391509P | ACTIVE | Non-Hazardous | ROOF DECK IS PHYWOOD AND DOES NOT MEET REQUIREMENTS FOR CLASS I NON COMBUSTIBLE CONSTRICTION | $400 | $0 | Mar 11, 2004 |
| Oct 28, 2002 | 34391510M | ACTIVE | Non-Hazardous | ROOF DECK IS PLYWOOD AND DOES NOT MEET REQUIREMTNS FOR CLASS I NON COMBUSTIBLE CONSTRUCTION | $400 | $0 | Mar 11, 2004 |
| Oct 28, 2002 | 34391520X | ACTIVE | Non-Hazardous | FAILURE TO PROVIDE MINIMUM # OF PARKING SPACES FOR ZONING LOT.ENCLOSED SPACES PROVIDED HAVE BEEN CONVERTED TO HABITAB... | $480 | $0 | Mar 11, 2004 |
| Oct 28, 2002 | 34391360X | ACTIVE | Non-Hazardous | LADDER TO ROOF SCUTTLE AT 4TH FLOOR IS MISSING/ INCONVENIENTLY LOCATED, MAKING ACCESS TO SCUTTLE DIFFICULT. REMEDY: P... | $400 | $0 | Mar 11, 2004 |
| Oct 28, 2002 | 34391382R | ACTIVE | Non-Hazardous | GUARDRAILS NOT PROVIDED AT ROOF. GUARDRAILS/PARAPET MUST BE MINIMUM OF 3'6' HIGH. REMEDY: PROVIDE GUARDRAILS. | $400 | $0 | Mar 11, 2004 |
| Oct 28, 2002 | 34391394Y | ACTIVE | Non-Hazardous | 10 FT LINE WINDOWS USED TO PROVIDE REQUIRED VENTILATION REMEDY: PROVIDE ALTERNATE MEANS OF VERTILATION | $400 | $0 | Mar 11, 2004 |