Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Sep 23, 2025 39161371J RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 ... $2,500 -$30 Nov 2, 2026
Sep 22, 2025 39161165Z ACTIVE CLASS - 2 CLASS 2 ITEMS: FIRE EXTINGUISHER TEST TAG EXPIRED, SERVICE AND REPLACE THE TAG. PROVIDE UPDATED MAINTENANCE LOG. IN-C... $655 $655 Nov 5, 2026
Oct 21, 2024 39128043X RESOLVE CLASS - 2 OBSERVED THROUGHOUT STAIRWAY DRAIN RISER FOR SPRINKLER NOT PAINTED. AS PER 903.6.1 OF THE BUILDING CODE WHERE A STAND... $0 $0 Dec 31, 2024
Oct 21, 2024 39128042Y RESOLVE CLASS - 2 OBSERVED COMMERCIAL QUICK DISCONNECT FLEXIBLE PIPING INSTALLED ON COMMERCIAL LAUNDRY EQUIPMENT. COMMERCIAL QUICK DISC... $0 $0 Dec 31, 2024
Feb 13, 2020 35459247Z RESOLVE CLASS - 2 ELECTRICAL WORK W/O A PERMIT. I OBSERVED IN THE FRONT LOBBY RECEPTION DESK FLEXIBLE EXTENSION CORD THAT HAS BEEN CUT ... $800 $0 Jul 21, 2020
Feb 13, 2020 35475603X RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED AT ABOVE ADDRESS IN LAUNDRY AT CELLAR 2 COMMERCIAL DR... $1,562 $0 Oct 27, 2020
Feb 13, 2020 37018424J RESOLVE CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... $625 $0 Oct 13, 2020
Feb 13, 2020 35459246R RESOLVE CLASS - 2 400.8(NEC) FLEXIBLE EXTENSION CORDS USED AS A PERMANENT WIRING METHOD.I OBSERVED IN THE CELLAR FLEXIBLE EXTENSION COR... $0 $0 Apr 28, 2020
Jul 24, 2019 39006286P RESOLVE CLASS - 2 GAS METER ROOM IN THE CELLAR LEVEL MISSING FIRE STOP AROUND GAS LINE, SECTION OF WALL MISSING IN REAR OF ROOM, ALSO M... $0 $0 Sep 10, 2019
Jul 24, 2019 39006285N RESOLVE CLASS - 1 OBSERVED IN ELECTRICAL EQUIPMENT ROOM THE INSTALLATION OF AN EXTENSION CORD INTO THE ELECTRICAL PANEL. NOTE UNABLE TO... $1,600 $0 Sep 10, 2019
Jul 24, 2019 39006287R RESOLVE CLASS - 2 EMERGENCY LIGHT NOT WORKING IN MANY AREAS WHEN TESTED THRU OUT BUILDING, REPAIR AND/OR REPLACE LIGHTING $0 $0 Sep 10, 2019
Sep 10, 2018 38265123K RESOLVE CLASS - 2 57M7,59BB5-57M7)MACHINE ROOM FIRE EXTINGUISHER MISSING. 59BB5)BRAKE MAINTENANCE TAG EXPIRED. $0 $0 Oct 30, 2018
Jul 5, 2018 35341986Z RESOLVE CLASS - 1 SEC. 403.8 MISC VIOLATION. UNPAINTED GAS PIPING NOT PROTECTED FROM ERROSION & THE ELEMENTS. OBSERVED ON THE ROOF GAS ... $2,500 $0 Aug 21, 2018
Jul 5, 2018 35336440K RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.ILLUMINATION FOREXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER ... $0 $0 Aug 21, 2018
Jul 5, 2018 35341984P RESOLVE CLASS - 3 FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER. OBSERVED IN CELLAR IN GAS METER ROOM EXCESSIVE STORAGE AROUND GA... $0 $0 Aug 21, 2018
Jul 5, 2018 35336441M RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.NO FIRE STOPPING PERBC712.3;27-345.NOTED:OBSERVED AT CELLAR LAUNDRY... $0 $0 Aug 21, 2018
Jul 5, 2018 35341983N RESOLVE CLASS - 3 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED IN CELLAR AT SPRINKLER(FIRE)CONTROL VALVE NO SPARE HEADS ... $0 $0 Aug 21, 2018
Jul 5, 2018 35341985R RESOLVE CLASS - 1 SEC. 411.1 RESIDENTIAL GAS FLEX USED ON COMMERCIAL EQUIPMENT MISC VIOLATION. OBSERVED IN CELLAR RESIDENTIAL GAS FLEX ... $2,500 $0 Aug 21, 2018
Oct 9, 2009 34785806N RESOLVE CLASS - 1 SEC. 3301.7. FAILURE TO PROVIDE DESIGN DRAWINGS - NOTED: FAILURE TO PROVIDE DESIGN DRAWINGS FOR 3 WORK PLATFORMS (ELE... $1,600 $0 Dec 8, 2009
Feb 11, 2009 34759028R RESOLVE CLASS - 1 FAILURE TO SAFEGUARD PUBLIC & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. NOTED: AT TIME OF INSPECTION ON AN ACTIVE... $2,400 $0 Apr 7, 2009
Sep 3, 2008 34697406Y RESOLVE CLASS - 1 FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION NO TOE BOARDS. MISSING TOE BOARDS A... $1,000 $0 Oct 28, 2008
Sep 3, 2008 34697407X RESOLVE CLASS - 1 SEC. 27-203 MISC. VIOLATIONS. FAILURE TO COMPLY WITH SAFETY REQUIREMENTS DURING BUILDING OPERATIONS. SCAFFOLDS INSTAL... $1,600 $0 Oct 28, 2008
Aug 11, 2008 34695302K RESOLVE CLASS - 1 INADEQUATE SAFETY MEASURES: OPER'N OF CRANE/DERRICK/HOISTING EQUIP IN UNSAFE MANNER. HOISTING STEEL BEAMS W/FORKS INS... $0 $0 Nov 17, 2009