ECB violations
140-30A 34 Avenue, Queens • Block 04994 • Lot 0225
11 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jul 18, 2002 | 34338810L | ACTIVE | Non-Hazardous | DID NOT PROVIDE. MIN 8% STREET FRONTAGE AS REQUIRED. REMEDY: PROVIDE WAIVER FROM F.D AND RECONSIDERATION FROM B.C. | $400 | $0 | Feb 12, 2003 |
| Jul 18, 2002 | 34338391X | ACTIVE | Non-Hazardous | GUARD RAILS ARE NOT PROVIDED AT SECTION OF BRICK PARAPET THAT ARE LESS THAN 3 OF 6. REMEDY: PROVIDE GUARDRAILS AT PAR... | $400 | $0 | Feb 12, 2003 |
| Jul 18, 2002 | 34338392H | ACTIVE | Non-Hazardous | EXTERIOR GAS SERVICES NOT PROPERLY PROTECTED BY BATHARDS FROM VEHICULAR TRAFFIC AT 1 FLOOR PARKING AREA. REMEDY: PROV... | $400 | $0 | Feb 12, 2003 |
| Jul 18, 2002 | 34338820P | ACTIVE | Non-Hazardous | PLASTIC SKYLIGHTS AT TOP OF STAIRS ENCLOSER ARE NOT PERMITTED SKYLINGTS ARE NOT VENTED AND NO PROPER WIRE GRATING PRO... | $400 | $0 | Feb 12, 2003 |
| Jul 18, 2002 | 34338394L | ACTIVE | Non-Hazardous | BOILER FLUE NOT CARRIED 3 FEET ABOVE HIGHEST ROOF CONSTRUCTION (PARAPET WALL). REMEDY: RAISE FLUE PIPE 3 FEET ABOVE H... | $400 | $0 | Feb 12, 2003 |
| Jul 10, 2002 | 34333539K | ACTIVE | Non-Hazardous | FAILURE TO PROVIDE REQUIRED NUMBER OF PARKING SPACES IN AN R6 DISTRICT ENCLOSED ACCESSARY OFF STREET PARKING SPACE DO... | $960 | $0 | Feb 12, 2003 |
| Jul 10, 2002 | 34340889X | ACTIVE | Non-Hazardous | LOT LINE WINDOWS INSTALLED WITHOUT A PERMIT NOT SHOWN ON PLANS. REMEDY: OBTAIN A PERMIT OR REMOVE WINDOWS. | $500 | $0 | Feb 12, 2003 |
| Jul 10, 2002 | 34340900H | ACTIVE | Non-Hazardous | APARTMENT DOOR DIRECTLY TO STAIR ENCLOUSRE WHICH IS NOT PERMITTED IN A BUILDING OVER THREE STORIES. REMEDY: COMPLY WI... | $400 | $0 | Feb 12, 2003 |
| Jul 10, 2002 | 34340878K | ACTIVE | Non-Hazardous | CELLAR STAIR IS NOT ENCLOSED BECAUSE THERE IS NO FIRE PROOF SELF CLOSING DOOR AND NO RATED ENCLUSURE WALL AT TOP OF S... | $400 | $0 | Feb 12, 2003 |
| Jun 10, 2002 | 34338393J | ACTIVE | Non-Hazardous | 1 HOURE RATED BOILER ENCLOUSE (WALL) IS PENETRATED BY AN UNRATED 10' DIAMETER METAL BOILER FLUE COMPROMISING INTEGRAT... | $400 | $0 | Feb 12, 2003 |
| Jun 7, 2002 | 34338400Z | ACTIVE | Non-Hazardous | WORK CONTRARY TO PLANS IN THAT GARAGE DIMENSIONS SMALLER THAN SPECIFIED (2) ROOF DECKING CONSTRUCTED OF PLYWOOD INSTE... | $500 | $0 | Feb 12, 2003 |