Jul 18, 2002 34338832M ACTIVE Non-Hazardous FAILURE TO PROVIDE ACCESS TO ROOF VIA INTERIO R STAIR NO ROOF BULK HAEAD PROVIDED FOR 4 FAMILY DWELLING. REMEDY: PROV... $400 $0 Feb 12, 2003
Jul 18, 2002 34340879M ACTIVE Non-Hazardous CELLAR STAIR IS NOT ENCLOSED BECAUSE THERE IS NO FIRE PROOF SELFT CLOSING DOOR AND RATED WALL AT TOP OF STAIRS. REMED... $400 $0 Feb 12, 2003
Jul 18, 2002 34333533J ACTIVE Non-Hazardous STAIR ENCLOSURE DOES NOT MEET THE REQUIRED TWO HOUR RATING DUE TO MISSING PIECE OF DRYWALL AT STAIR SIDE OF ENCLOSING... $400 $0 Feb 12, 2003
Jul 18, 2002 34333526L ACTIVE Non-Hazardous APARTMENT DOOR OPENS DIRECTLY TO STAIR ENCLOSURE WHICH IS NOT PERMITTED IN A BUILDING OVER THREE STORIES. REMEDY: COM... $400 $0 Feb 12, 2003
Jul 18, 2002 34338580P ACTIVE Non-Hazardous GUARD RAILS ARE NOT PROVIDED AT SECTIONS OF BRICK PARAPET THAT ARE LESS THAN 3F 6" REMEDY - PROVIDE GUARD RAILS AT PA... $400 $0 Feb 12, 2003
Jul 18, 2002 34338581R ACTIVE Non-Hazardous EXTERIOR GAS SERVICE'S NOT PROPERLY PROTECTED BY BOOARDS VEHICULAR TRAFFIC AT 1ST FLOOR PARKING AREA. REMEDY - PROVID... $400 $0 Feb 12, 2003
Jul 18, 2002 34338679P ACTIVE Non-Hazardous BOILER FLUE NOT CARRIED 3 FEET ABOVE HIGHEST CONSTRUCTION ( PARAPET WALL ) REMEDY - RAISE FLUE PIPE 3 FEET ABOVE HIGH... $400 $0 Feb 12, 2003
Jul 18, 2002 34338843H ACTIVE Non-Hazardous LOT LIN EWINDOWS ARE IMPROPERLY USED TO SUPPLY REQUIRED VENTILATION. REMEDY: PROVIDE PROPER VENTILATION. $400 $0 Feb 12, 2003
Jul 18, 2002 34338801J ACTIVE Non-Hazardous WORK CONTRARY TO PLANS IN THAT GARAGE DIMENSIONS SMALLER THAN SPECIFIED (2) ROOF DECKING CONSTRUCTED OF PLYWOOD INSTE... $500 $0 Feb 12, 2003
Jul 18, 2002 34338821R ACTIVE Non-Hazardous XLASTIC SKYLIGHTS AT TOP OF STAIR ENCLOSURE ARE NOT PERMITTED SKYLIGHTS ARE NOT VENTED AND NO PROPER WIRE GRATING PRO... $400 $0 Feb 12, 2003
Jun 10, 2002 34338689Z ACTIVE Non-Hazardous 1-HOUR RATED BOILER ENCLOSURE (WALL) IS PENETRATED BY AN UNRATED 10" DIAMETER METAL BOILER FLUE COMPROMISING INTEGRIT... $400 $0 Feb 12, 2003
Jun 7, 2002 34340890N ACTIVE Non-Hazardous LOT LINE WINDOWS INSTALLED WITHOUT A PERMIT NOT SHOWN ON PLANS. REMEDY: OBTAIN A PERMIT OR REMOVE WINDOWS. $500 $0 Feb 12, 2003
Jun 7, 2002 34333540H ACTIVE Non-Hazardous FAILURE TO PROVIDE REQUIRED NUMBER OF PARKING SPACES IN AN R6 DISTRICT ENCLOSED ACCESSARY OFF STREET PARKING SPACE DO... $960 $0 Feb 12, 2003
Aug 24, 2001 34288193M RESOLVE Non-Hazardous QUESTIONABLE CONSTRUCTION UPON INSPECTION OF ABOVE PROPERTY C JOIST ON THE 1ST & 2ND FLS HAVE NO T-ANCHORS & STRAPPIN... $2,500 $0 Feb 12, 2003