ECB violations
142-24 38 Avenue, Queens • Block 05020 • Lot 0017
31 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Dec 26, 2024 | 35689421Z | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE: AT THE TIME OF INSPECTION OBSERVED: AT EXP #4 W... | $2,500 | $0 | Mar 4, 2025 |
| Oct 1, 2024 | 37030219M | RESOLVE | CLASS - 1 | FAILURE TO SUBMIT THE REQUIRED PARKING STRUCTURE INITIAL OBSERVATION REPORT FOR AN EXISTING PARKING STRUCTURE DOCUMEN... | $625 | $0 | Dec 22, 2025 |
| Sep 30, 2024 | 39126144X | RESOLVE | CLASS - 1 | CEASE USE ITEMS: DOOR ZONE RESTRICTOR INOPERATIVE. THIS IS A SAFETY FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY: T... | $1,280 | $0 | Dec 10, 2024 |
| Sep 20, 2024 | 35686827P | ACTIVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTE:-AT THE TIME OF INSPECTION, OBSERVED A/C UNITS OBJECTING EGRESS... | $1,250 | $0 | May 6, 2025 |
| Sep 20, 2024 | 35686523X | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE:-AT THE TIME OF INSPECTION, OBSERVED AT EXP #4 W... | $2,500 | $0 | May 6, 2025 |
| Jul 29, 2024 | 39120119R | ACTIVE | CLASS - 1 | THE ONLY ELEVATOR IN BUILDING (OR SECTION OF BUILDING) OUT OF SERVICE. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT... | $1,250 | $0 | Apr 15, 2025 |
| Apr 11, 2024 | 37028185K | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $0 | $0 | Jul 30, 2024 |
| Jan 7, 2020 | 35458255Y | RESOLVE | CLASS - 2 | REMOVAL OF SAFETY MEASURE,SUCH AS SIDEWALK SHED'S W/O DEPT APPROVAL. NOTE:AT THE TIME OF INSPECTION BUILDING FACADE W... | $0 | $0 | Jan 5, 2021 |
| Nov 8, 2018 | 35365182J | RESOLVE | CLASS - 1 | FAILURE TO TAKE PROVIDE SAFETY MEASURE SUCH AS SIDEWALK SHEDS, FENCE ETC WHERE REQUIRED TO PROTECT AND SECURE PUBLIC ... | $10,000 | $0 | May 21, 2019 |
| May 29, 2018 | 38263431N | RESOLVE | CLASS - 2 | 8V1-DEVICE NOT LEVEL AT THE FLOORS; 57M7-FIRE EXTINGUISHER MISSING IN MACHINE ROOM. | $0 | $0 | Jul 17, 2018 |
| Mar 19, 2018 | 38260573P | RESOLVE | CLASS - 1 | 97-X-07:THE ONLY ELEVATOR IN BLDG OUT OF SERVICE UPON INSP IN DEVICE IS FOUND TO BE 0/0/0 CREATING A HAZARDOUS CONDIT... | $1,250 | $0 | May 8, 2018 |
| Apr 12, 2017 | 38254810Z | RESOLVE | CLASS - 1 | 16D10,29J01,21I11,07I10. 16D10-PUT HOISTWAY DOOR BACK ON TRACK; 29J01-REPAIR 2ND BATCH DOOR HANGERS; 21IHH-REPLACE BR... | $400 | $0 | Oct 24, 2017 |
| Mar 20, 2017 | 32087421L | RESOLVE | CLASS - 2 | 11,15,34A,50A,50B. B254Y 50A)RETURN PUMPS MAKING EXCESSIVE NOISE B)NOSTORAGE IN BOILER ROOM. CORRECT ALL VIOLATING CO... | $0 | $0 | May 9, 2017 |
| Mar 15, 2017 | 38253707X | RESOLVE | CLASS - 1 | 97X17. THE ONLY ELEVATOR IN BLDG OUT OF SERVICE. UPON INSP THE DEVICE IS FOUND TO BE OUT OF SERVICE CREATING A HAZARD... | $1,000 | $0 | May 2, 2017 |
| Dec 17, 2016 | 38251198H | RESOLVE | CLASS - 1 | 97X10 RESTORE TO SERVICE. | $1,000 | $0 | Jan 31, 2017 |
| Dec 7, 2016 | 38251689M | RESOLVE | CLASS - 2 | 5H11,10H11. (05H)NEED REPLACE HANGER ROLLERS & DOOR GIBS. | $0 | $0 | Jan 24, 2017 |
| Jul 18, 2016 | 38244294M | ACTIVE | CLASS - 1 | 07L10 ZONE RESTRICTOR TIED UP. | $1,000 | $0 | May 23, 2017 |
| Jan 24, 2015 | 38234679Y | RESOLVE | CLASS - 2 | 10L11,10M07 REPLACE WORN CAR DOOR GIBS; 10-PROVIDE MISSING FIRE DOOR GIB | $0 | $0 | Mar 10, 2015 |
| Dec 29, 2014 | 35095384K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR OF BLDG & APPURTENANCES.NORTH ELEV.EXP.1 WOOD SUPPORTING A/C UNIT FLOORS 6 & 5 & 4 BRICK... | $0 | $0 | Feb 17, 2015 |
| Jan 6, 2014 | 35024253M | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BUILDING. DETERIORATED LINTEL ABOVE GRILLEXP#2. DETERIORATED CROSS JOINTS AT COPING STOV... | $250 | $0 | Feb 25, 2014 |
| Mar 8, 2011 | 38215220R | RESOLVE | CLASS - 2 | 77B11/ 98BB05/ 99BB05/ 03M07/ 77B11 REPLACE TOE GUARD AS PER K-3 03M07PROVIDE 24 HOUR EMERGENCY COMMUNICATION AS PER K-3 | $0 | $0 | Apr 26, 2011 |
| Dec 22, 2010 | 38214150X | RESOLVE | CLASS - 2 | 98BB05,99BB05,77B11. 77- PROVIDE PROPER SIZE TOE GUARD 3.3.2 | $250 | $0 | Feb 15, 2011 |
| Feb 6, 2009 | 36008425X | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF E... | $800 | $0 | Aug 18, 2009 |
| Nov 1, 2005 | 38156101R | RESOLVE | Non-Hazardous | 10/H/11-21/D/06-08/V/01-66/O/02. 10-H-11 CAR DOOR GIBS ARE WORN. 21-D-06 INTERLOCK COVER ON 3 FLOOR IS NOT PROPERY SE... | $0 | $0 | Dec 20, 2005 |
| Apr 30, 2003 | 38138056H | RESOLVE | Non-Hazardous | 79O02/ 19M07/ 62O02/ 16O02/ 36O02/ 30O02/ 17H12/ 37P17/ 19-M- INTERLOCK COVERS MISSING 17-H- HOISTWAY DOOR GIBS 2ND F... | $0 | $0 | Jun 17, 2003 |
| Feb 6, 2001 | 38110505J | RESOLVE | Non-Hazardous | 39R07,37E11,51F11(39)FILE APPLICATION FOR REGROOVE SHEAVE(37)REPAIR SELECTOR CHAIN AT CWT SIDE(51)REPAIR WORM AND GEARS. | $530 | $0 | Mar 27, 2001 |
| Dec 29, 1999 | 38091960K | RESOLVE | Non-Hazardous | 39H,8V,21L. REGROOVE MACHINE SHEAVE, ADJUST FLOOR STOP, REPAIR IN CARINDICATORS. | $0 | $0 | Feb 15, 2000 |
| Jun 16, 1999 | 38086637Y | ACTIVE | Non-Hazardous | 07J 38F 30O 50O 07 CAR SAFTEY EDGE DOOR OPERATOR NEED ADJUSTING 38 RFR NEEDS TO BE REFORCE | $180 | $0 | Sep 8, 1999 |
| May 25, 1999 | 38086880Y | RESOLVE | Non-Hazardous | PUT ELEVATOR BACK TO NORMAL SERVICE, SO A COMPLETE INSPECTION CAN BE MADE BY THIS DEPARTMENT. | $0 | $0 | Jul 13, 1999 |
| Feb 9, 1993 | 38030187N | RESOLVE | Non-Hazardous | 46H,28H, | $0 | $0 | Mar 23, 1993 |
| Aug 10, 1990 | 38000394Z | RESOLVE | Non-Hazardous | 46L,73#,73O,73)PERFORM A 5 YEAR TEST AND FILE FORM ELV3 | $0 | $0 | Sep 25, 1990 |