Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Dec 26, 2024 35689421Z RESOLVE CLASS - 1 FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE: AT THE TIME OF INSPECTION OBSERVED: AT EXP #4 W... $2,500 $0 Mar 4, 2025
Oct 1, 2024 37030219M RESOLVE CLASS - 1 FAILURE TO SUBMIT THE REQUIRED PARKING STRUCTURE INITIAL OBSERVATION REPORT FOR AN EXISTING PARKING STRUCTURE DOCUMEN... $625 $0 Dec 22, 2025
Sep 30, 2024 39126144X RESOLVE CLASS - 1 CEASE USE ITEMS: DOOR ZONE RESTRICTOR INOPERATIVE. THIS IS A SAFETY FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY: T... $1,280 $0 Dec 10, 2024
Sep 20, 2024 35686827P ACTIVE CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTE:-AT THE TIME OF INSPECTION, OBSERVED A/C UNITS OBJECTING EGRESS... $1,250 $0 May 6, 2025
Sep 20, 2024 35686523X ACTIVE CLASS - 1 FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE:-AT THE TIME OF INSPECTION, OBSERVED AT EXP #4 W... $2,500 $0 May 6, 2025
Jul 29, 2024 39120119R ACTIVE CLASS - 1 THE ONLY ELEVATOR IN BUILDING (OR SECTION OF BUILDING) OUT OF SERVICE. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT... $1,250 $0 Apr 15, 2025
Apr 11, 2024 37028185K RESOLVE CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... $0 $0 Jul 30, 2024
Jan 7, 2020 35458255Y RESOLVE CLASS - 2 REMOVAL OF SAFETY MEASURE,SUCH AS SIDEWALK SHED'S W/O DEPT APPROVAL. NOTE:AT THE TIME OF INSPECTION BUILDING FACADE W... $0 $0 Jan 5, 2021
Nov 8, 2018 35365182J RESOLVE CLASS - 1 FAILURE TO TAKE PROVIDE SAFETY MEASURE SUCH AS SIDEWALK SHEDS, FENCE ETC WHERE REQUIRED TO PROTECT AND SECURE PUBLIC ... $10,000 $0 May 21, 2019
May 29, 2018 38263431N RESOLVE CLASS - 2 8V1-DEVICE NOT LEVEL AT THE FLOORS; 57M7-FIRE EXTINGUISHER MISSING IN MACHINE ROOM. $0 $0 Jul 17, 2018
Mar 19, 2018 38260573P RESOLVE CLASS - 1 97-X-07:THE ONLY ELEVATOR IN BLDG OUT OF SERVICE UPON INSP IN DEVICE IS FOUND TO BE 0/0/0 CREATING A HAZARDOUS CONDIT... $1,250 $0 May 8, 2018
Apr 12, 2017 38254810Z RESOLVE CLASS - 1 16D10,29J01,21I11,07I10. 16D10-PUT HOISTWAY DOOR BACK ON TRACK; 29J01-REPAIR 2ND BATCH DOOR HANGERS; 21IHH-REPLACE BR... $400 $0 Oct 24, 2017
Mar 20, 2017 32087421L RESOLVE CLASS - 2 11,15,34A,50A,50B. B254Y 50A)RETURN PUMPS MAKING EXCESSIVE NOISE B)NOSTORAGE IN BOILER ROOM. CORRECT ALL VIOLATING CO... $0 $0 May 9, 2017
Mar 15, 2017 38253707X RESOLVE CLASS - 1 97X17. THE ONLY ELEVATOR IN BLDG OUT OF SERVICE. UPON INSP THE DEVICE IS FOUND TO BE OUT OF SERVICE CREATING A HAZARD... $1,000 $0 May 2, 2017
Dec 17, 2016 38251198H RESOLVE CLASS - 1 97X10 RESTORE TO SERVICE. $1,000 $0 Jan 31, 2017
Dec 7, 2016 38251689M RESOLVE CLASS - 2 5H11,10H11. (05H)NEED REPLACE HANGER ROLLERS & DOOR GIBS. $0 $0 Jan 24, 2017
Jul 18, 2016 38244294M ACTIVE CLASS - 1 07L10 ZONE RESTRICTOR TIED UP. $1,000 $0 May 23, 2017
Jan 24, 2015 38234679Y RESOLVE CLASS - 2 10L11,10M07 REPLACE WORN CAR DOOR GIBS; 10-PROVIDE MISSING FIRE DOOR GIB $0 $0 Mar 10, 2015
Dec 29, 2014 35095384K RESOLVE CLASS - 2 FAILURE TO MAINTAIN EXTERIOR OF BLDG & APPURTENANCES.NORTH ELEV.EXP.1 WOOD SUPPORTING A/C UNIT FLOORS 6 & 5 & 4 BRICK... $0 $0 Feb 17, 2015
Jan 6, 2014 35024253M RESOLVE CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING. DETERIORATED LINTEL ABOVE GRILLEXP#2. DETERIORATED CROSS JOINTS AT COPING STOV... $250 $0 Feb 25, 2014
Mar 8, 2011 38215220R RESOLVE CLASS - 2 77B11/ 98BB05/ 99BB05/ 03M07/ 77B11 REPLACE TOE GUARD AS PER K-3 03M07PROVIDE 24 HOUR EMERGENCY COMMUNICATION AS PER K-3 $0 $0 Apr 26, 2011
Dec 22, 2010 38214150X RESOLVE CLASS - 2 98BB05,99BB05,77B11. 77- PROVIDE PROPER SIZE TOE GUARD 3.3.2 $250 $0 Feb 15, 2011
Feb 6, 2009 36008425X ACTIVE CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF E... $800 $0 Aug 18, 2009
Nov 1, 2005 38156101R RESOLVE Non-Hazardous 10/H/11-21/D/06-08/V/01-66/O/02. 10-H-11 CAR DOOR GIBS ARE WORN. 21-D-06 INTERLOCK COVER ON 3 FLOOR IS NOT PROPERY SE... $0 $0 Dec 20, 2005
Apr 30, 2003 38138056H RESOLVE Non-Hazardous 79O02/ 19M07/ 62O02/ 16O02/ 36O02/ 30O02/ 17H12/ 37P17/ 19-M- INTERLOCK COVERS MISSING 17-H- HOISTWAY DOOR GIBS 2ND F... $0 $0 Jun 17, 2003
Feb 6, 2001 38110505J RESOLVE Non-Hazardous 39R07,37E11,51F11(39)FILE APPLICATION FOR REGROOVE SHEAVE(37)REPAIR SELECTOR CHAIN AT CWT SIDE(51)REPAIR WORM AND GEARS. $530 $0 Mar 27, 2001
Dec 29, 1999 38091960K RESOLVE Non-Hazardous 39H,8V,21L. REGROOVE MACHINE SHEAVE, ADJUST FLOOR STOP, REPAIR IN CARINDICATORS. $0 $0 Feb 15, 2000
Jun 16, 1999 38086637Y ACTIVE Non-Hazardous 07J 38F 30O 50O 07 CAR SAFTEY EDGE DOOR OPERATOR NEED ADJUSTING 38 RFR NEEDS TO BE REFORCE $180 $0 Sep 8, 1999
May 25, 1999 38086880Y RESOLVE Non-Hazardous PUT ELEVATOR BACK TO NORMAL SERVICE, SO A COMPLETE INSPECTION CAN BE MADE BY THIS DEPARTMENT. $0 $0 Jul 13, 1999
Feb 9, 1993 38030187N RESOLVE Non-Hazardous 46H,28H, $0 $0 Mar 23, 1993
Aug 10, 1990 38000394Z RESOLVE Non-Hazardous 46L,73#,73O,73)PERFORM A 5 YEAR TEST AND FILE FORM ELV3 $0 $0 Sep 25, 1990