ECB violations
133-12-133-14 41 Avenue, Queens • Block 05041 • Lot 0005
36 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Mar 29, 2021 | 39038426Y | RESOLVE | CLASS - 2 | UPON INSPECTION DEVICE WAS FOUND WITH THE MAIN LINE IN THE OFF POSITION OUT OF SERVICE. RESTORE TO SERVICE IMMEDIATEL... | $625 | $0 | May 24, 2022 |
| May 26, 2016 | 35158334H | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROERTY AFFECTED BY CONSTRUCTION OPERATION. NOTE: AS PER SSM MR.SUANTER THAT, WORK... | $5,000 | $0 | Jul 14, 2016 |
| Mar 15, 2016 | 35165964H | RESOLVE | CLASS - 2 | TEMPORARY CONSTRUCTION EQUIPMENT ON SITE EXPIRED PERMIT. AT TIME OF INSPECTION FOR PARTIAL SHED REMOVAL, OBSERVED SID... | $0 | $0 | May 3, 2016 |
| Feb 20, 2016 | 35145218H | RESOLVE | CLASS - 1 | FAILURE TO HAVE SITE SAFETY COORDINATOR PRESENT AS REQUIRED.@TIME OF INSP OBSERVED 10 STORY NB UNDER CONST APPROX 8 W... | $6,000 | $0 | Apr 5, 2016 |
| Feb 20, 2016 | 35145219J | RESOLVE | CLASS - 1 | WORK W/OUT AFTER HRS VARIANCE PERMIT.@TIME OF INSP OBSERVED NB UNDER CONST.APPROX 8 WORKERS ONSITE PERFORMING VARIOUS... | $800 | $0 | Apr 5, 2016 |
| Jan 26, 2016 | 35166308Y | RESOLVE | CLASS - 2 | BC3303.12 HOIST FAILURE TO HAVE ELEVATOR N READINESS. AT TIME OF INSPECTION OF 10STORY NEW BUILDING UNDER CONSTRUCTIO... | $0 | $0 | Mar 15, 2016 |
| Nov 23, 2015 | 35162271L | RESOLVE | CLASS - 1 | SEC. 3314.4.3 NO RECORD OF DAILY INSPECTION OF SUPPORTED SCAFFOLD PERFORMED BY COMPETENT PERSON AT SITE. NOTE: OBSERV... | $1,600 | $0 | Jan 28, 2016 |
| Nov 23, 2015 | 35162270J | RESOLVE | CLASS - 2 | SEC. 28-110.1 AT TIME OF INSPECTION OF ACTIVE JOB SITE OF A 10 STY BLDG OBSERVED 4 WORKERS W/O 10HRS OSHA CARD REQUIR... | $0 | $0 | Jan 12, 2016 |
| Nov 23, 2015 | 35162272N | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. AT 1ST FL EGRESS OBSTRUCTED BY PALLET OF CEMENT W/DOLLY PILED W/BRIC... | $1,200 | $0 | Jan 28, 2016 |
| Nov 23, 2015 | 35162273P | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN: GUARDRAILS. NOTE: OBSERVED ACTIVE JOBSITE,AT THE 4TH FL LEVEL OBSERVED GUARDRAIL/V NETTING IN PL... | $1,200 | $0 | Jan 28, 2016 |
| Aug 13, 2015 | 35132937L | RESOLVE | CLASS - 1 | 3314.8.1 PARTIAL STOP WORK ORDER FOR SUPPORTED SCAFFOLD ISSUED PURSUANT TO 28-207.2 & POSTED @PREMISE SUPPORTED SCAFF... | $1,600 | $0 | Sep 29, 2015 |
| Aug 13, 2015 | 35132939P | RESOLVE | CLASS - 1 | 3314.1 PARTIAL STOP WORK ORDER FOR SUPPORTED SCAFFOLD ISSUED PURSUANT TO 28-207.2 & POSTED @PREMISES.SCAFFOLD IN UNSA... | $1,600 | $0 | Sep 29, 2015 |
| Aug 13, 2015 | 35132938N | RESOLVE | CLASS - 2 | 3314.4.3.3 PARTIAL STOP WORK ORDER FOR SUPPORTED SCAFFOLD ISSUED PURSUANT TO 28-207.2 & POSTED @PREMISES.INSTALLATION... | $0 | $0 | Sep 29, 2015 |
| Jul 22, 2015 | 35146343L | RESOLVE | CLASS - 2 | SEC. 3314.4.4 MATERIALS ON SCAFFOLD WHILE WORK NOT IN PROGRESS AT TIMEOF INSPECTION ACTIVE CONSTRUCITON SITE OBSERVED... | $400 | $0 | Sep 8, 2015 |
| Jul 22, 2015 | 35146342J | RESOLVE | CLASS - 2 | SEC. 28-110.1 AT TIME OF INSPECTION ACTIVE JOB SITE OF A 10 STY BLDG OBSERVED WORKERS ON SITE MASONRY WORK 2 WORKERS ... | $400 | $0 | Sep 8, 2015 |
| Mar 19, 2015 | 35109503Z | RESOLVE | CLASS - 1 | BC3314.8 ACTIVE JOBSITE BUILDING COMPLETE TO ROOF WITH SUPPORTED SCAF FOLD INSALLED AT EXP1,2,3,4 OBSERVED AT TIME OF... | $1,600 | $0 | May 5, 2015 |
| Mar 19, 2015 | 35109502R | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION ACTIVE JOB SITE BUILDING COMPLETE TO ROOF OBSERVED MASONS ON SOUTH ELEVATION OF BLDG WORKING ON... | $1,630 | $0 | May 5, 2015 |
| Oct 20, 2014 | 35109845Z | RESOLVE | CLASS - 1 | FAILURE TO PERFORM SUCCESSFUL HYDROSTATIC PRESSURE TEST OF STANDPIPE SYSTEMS.AT TIME OF INSPECTION OBSERVED N.B. UNDE... | $2,400 | $0 | Dec 9, 2014 |
| Oct 18, 2014 | 35109841L | RESOLVE | CLASS - 1 | FAILURE TO HAVE SITE SAFETY COORDIANTOR PRESENT AS REQUIRED.AT TIME OFINSPECTION OBSERVED N.B. UNDER CONSTRUCTION. AP... | $1,200 | $0 | Dec 2, 2014 |
| Mar 20, 2014 | 35086989Z | RESOLVE | CLASS - 2 | 3301.1.2 FAILURE TO COMPLY WITH THE NYC FIRE CODE.NO FIRE SAFETY MANAGER ON SITE.@ THE TIME OF INSPECTION OBSERVED NB... | $0 | $0 | May 6, 2014 |
| Mar 20, 2014 | 35086988R | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN INSTITUE SAFETY EQUIPTMENT MEASURES OF TEMPOARY CONSTRUCTION.NO TOE BOARDS AT THE TIME OF INSPECT... | $1,000 | $0 | May 6, 2014 |
| Nov 4, 2013 | 35077195M | RESOLVE | CLASS - 2 | JOB SITE FENCE NOT CONSTRUCTED PURSUANT TO SUBSECTION.SECTION OF FENCEMISSING AT EXP4 OF THE BUILDING IN THE REAR.RMD... | $0 | $0 | Dec 24, 2013 |
| Apr 23, 2013 | 35012421Y | RESOLVE | CLASS - 2 | BC3310.6-FAILURE TO HAVE DESIGNATED SITE SAFETY MANAGER AS INDICATED ON PW-2 PRESENT ON SITE AT A MINIMUM OF ONCE EVE... | $0 | $0 | Jun 11, 2013 |
| Apr 4, 2012 | 34940945K | RESOLVE | CLASS - 2 | FAILURE TO POST "NO SMOKING SIGN" AT CONST SITE AS PER FIRE CODE AT TIME OF INSPECTION OBSERVED "NO SMOKING SIGN" POS... | $0 | $0 | May 22, 2012 |
| Apr 4, 2012 | 34940943R | RESOLVE | CLASS - 2 | FAILURE TO POST DOT PERMIT FOR STREET/SIDEWALK CLOSING AT TIME OF INSPECTION OBSERVED NO DOT PERMIT FOR MAINTAINING 5... | $0 | $0 | May 22, 2012 |
| Apr 4, 2012 | 34940944Z | RESOLVE | CLASS - 2 | 3310.6:FAILURE TO PROVIDE DESIGNATED SITE SAFETY MANAGER FOR JOB SITE AT TIME OF INSPECTION. AS PER DOB RECORDS NO SI... | $400 | $0 | May 22, 2012 |
| Apr 4, 2012 | 34940942P | RESOLVE | CLASS - 1 | 3307.3.2:FAILURE TO PROVIDE FENCE AS REQUIRED. PARTIAL STOP WORK ORDERISSUED PURSUANT TO 28-207.2 & POSTED AT PREMISE... | $1,600 | $0 | May 22, 2012 |
| Jan 10, 2011 | 34890100X | RESOLVE | CLASS - 2 | FAILURE TO POST PERMIT FOR WORK AT PREMISES. NO PERMITS POSTED TO IDENTIFY THE NB & FENCE. 410040398NB REMEDY: POST A... | $400 | $0 | Mar 1, 2011 |
| Jan 10, 2011 | 34890103L | RESOLVE | CLASS - 2 | SEC. BC3307.3.2 & 27-1021 FAILURE TO PROVIDE REQUIRED LOT LINE CONSTRUCTION FENCE. THERE IS NO 8FOOT HIGH SOLID WOOD ... | $0 | $0 | Mar 1, 2011 |
| Jan 10, 2011 | 34890104N | RESOLVE | CLASS - 2 | SEC. 3301.9.1 & RCNY 27-04 FAILURE TO PROVIDE A SIGN W/WORDING "TO ANONYMOUNSLY REPORT UNSAFE CONDITIONS AT THIS WORK... | $0 | $0 | Mar 1, 2011 |
| Jan 10, 2011 | 34890101H | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE/POST SIGNS AT JOB SITE PURSUANT TO SUBSECTION. NO CONTRACTOR'S SIGN POSTED. 410040398NB REMEDY: PR... | $0 | $0 | Mar 1, 2011 |
| Jul 13, 2000 | 32019131Z | RESOLVE | Non-Hazardous | 49 (1) SAFETY VALVE DISCHARGE REDUCED (2) WATER COLMN DRAIN REDUCED (3)GAGE GLOM TO FIT WITH DRAIN PIPE. | $0 | $0 | Aug 29, 2000 |
| Mar 1, 1992 | 32009789X | RESOLVE | Hazardous | BOILER MAN HOLE LEAKING UNDER THE TOP COVER B BOILER IS DESIGNED OF MAXIMUM PRESSURE OF 100PSI THE EXISTING SAFETY VA... | $250 | $0 | Jul 20, 1993 |
| Feb 7, 1991 | 32008163J | RESOLVE | Non-Hazardous | BOILER NOT REGISTERED. | $0 | $0 | May 28, 1991 |
| Feb 7, 1991 | 32008165N | RESOLVE | Non-Hazardous | BOILER NOT REGISTERED. | $125 | $0 | May 28, 1991 |
| Feb 7, 1991 | 32008164L | RESOLVE | Non-Hazardous | BOILER NOT REGISTERED. | $125 | $0 | May 28, 1991 |