ECB violations
144-44 41 Avenue, Queens • Block 05050 • Lot 0020
29 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Feb 16, 2022 | 35640148J | ACTIVE | CLASS - 1 | FAILURE TO PROVIDE SAFETY MEASURES SUCH AS SWSS,NETTING,FENCE ETC.TO PROTECT&SECURE PUBLIC SAFETY FROM TECHNICAL REPO... | $10,000 | $10,000 | Aug 2, 2022 |
| Jan 5, 2022 | 35640511P | ACTIVE | CLASS - 1 | FAILURE TO TAKE AND PROVIDE ADEQUATE SAFETY MEASURES SIDEWALK SHED,NETTING,FENCE,ETC. TO PROTECT AND SECURE PUBLIC SA... | $2,500 | $2,500 | Apr 5, 2022 |
| Jun 1, 2021 | 37021806M | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL ... | $10,000 | $10,000 | Jan 4, 2022 |
| Mar 24, 2021 | 39038213K | RESOLVE | CLASS - 2 | NEED LADDER AND PLATFORM FOR BOILERS OVER 8', FLUE PIPE TO BE WELDED STEEL, NO STORAGE IN BOILER ROOM CORRECT ALL VIO... | $0 | $0 | May 11, 2021 |
| Oct 15, 2018 | 37013390H | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPUR... | $6,250 | $6,250 | Apr 16, 2019 |
| Jan 17, 2018 | 38261000M | RESOLVE | CLASS - 1 | (C/U 45-X-10);71-M-07;67-X-10.(45-X-10)GOVERNOR SWITCH IS NOT OPERATIVE (71-M-07)MISSING PIT LIGHT (67-X-10)PHONE IS ... | $1,000 | $0 | Mar 6, 2018 |
| Jan 17, 2018 | 38261001Y | RESOLVE | CLASS - 2 | 16-E-01;(70-O-02);67-X-10.(16-E-01)ADJUST 4TH FL DOOR (70-O-02) CLEAN PIT (67-X-10)PHONE IS NOT OPERATIVE. | $250 | $0 | Mar 6, 2018 |
| Jan 8, 2018 | 38260475L | ACTIVE | CLASS - 1 | 05M07 CEASE USE ITEM. DOOR ZONE RESTRICTOR HAS BEEN TAMPERED/DISABLE AND RENDERED MISSING. THIS IS A SAETY DEVICE TO ... | $1,030 | $0 | Feb 27, 2018 |
| Nov 4, 2016 | 38250778J | ACTIVE | CLASS - 1 | 05M07. DOOR ZONE RESTROCTOR MISSING. PROVIDE. | $1,000 | $0 | Dec 20, 2016 |
| Dec 23, 2015 | 35147821L | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLAINT MANNER. NOTED: NORTH EAST SIDE FACING TO THE 41 AVE CONCRETE BLOCK WALL AP... | $0 | $0 | Feb 9, 2016 |
| Aug 1, 2015 | 38238233H | ACTIVE | CLASS - 2 | 98BB5,98M07,99BB05,56Y02,56Y13,39Y02. 98BB05-DOB RECORDS INDICATE THATCAT5 TEST WAS PERFORMED ON 12/28/09-FILE AND TA... | $500 | $0 | Sep 15, 2015 |
| Aug 1, 2015 | 38238234J | ACTIVE | CLASS - 2 | 42N09,56YO2,56Y13,98BB05,99M07,98M07,30Y02,70O02. 42N09-BYPASSED FUSE ON CONTROLLER; 98BB05-DOB RECORDS INDICATE THAT... | $500 | $0 | Sep 15, 2015 |
| Jan 17, 2015 | 38234678M | RESOLVE | CLASS - 2 | 15M07,68B07,100M07,16L10. 15-PROVIDE MISSING CERTIFICATE IN CAB(PROVIDED ONE);68-PROVIDE UPDATED MAINT LOG PROVIDE PR... | $0 | $0 | Mar 3, 2015 |
| Jan 17, 2015 | 38234677K | RESOLVE | CLASS - 2 | 61M07,68B07,99M07,100M07. 61-PROVIDE COMPANY NAME AND # ON MAIN LINE BOX; 68-PROVIDE UPDATED MAIT LOG; 99-PROVIDE CUR... | $2,500 | $0 | Mar 3, 2015 |
| Dec 26, 2014 | 35101051K | RESOLVE | CLASS - 2 | THE OUTERSIDE AND ENDS OF THE DECK OF THE SHED SHALL BE PROVIDED WITH A SUBSTANTIAL ENCLOSURE AT LEAST 3'6"HIGH (SIDE... | $800 | $0 | Feb 10, 2015 |
| Apr 10, 2012 | 34950788P | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. DEFECTS NOTED: @ THE REAR 1 STORY GARAGE FOR 48 CARS,HAS MULTI... | $1,000 | $0 | Aug 28, 2012 |
| Jun 30, 2011 | 36017217X | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCEWITH CODE PROVISIONS: PERIODIC INSPECTION OF EX... | $0 | $0 | Nov 15, 2011 |
| Sep 20, 2010 | 36015252M | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCEW/CODE PROVISIONS: PERIODIC INSPECTION OF EXTER... | $2,000 | $0 | Aug 23, 2011 |
| Aug 9, 2010 | 38212476R | RESOLVE | CLASS - 3 | 70O02,77B07.(70O02)CLEAN PIT.(77B07)PROVIDE 21" TOE GUARD AS PER A17.3 3.3.2. | $500 | $0 | Sep 28, 2010 |
| Aug 9, 2010 | 38212475P | RESOLVE | CLASS - 3 | 70O02,77B07.(77B07)PROVIDE 21" TOE GUARD A 17.3 3.3.2. | $500 | $0 | Sep 28, 2010 |
| Jul 7, 2010 | 36013696Y | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCEWITH CODE PROVISIONS:PERIODIC INSPECTION OF EXT... | $800 | $0 | Aug 23, 2011 |
| Jul 7, 2010 | 34852708R | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG WALL(S0OR APPURTENACES.NOTED:WINDOW A/C INSTALLED WITH LOOSE BRICKS,WOOD BLOCKING, OR OTHER ... | $500 | $0 | Aug 23, 2011 |
| Feb 17, 2010 | 36012176X | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/ CODE PROVISIONS PERIODIC INSP OF EXTERIOR... | $2,000 | $0 | Aug 23, 2011 |
| Feb 6, 2009 | 36008438P | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF E... | $4,000 | $0 | Aug 18, 2009 |
| Aug 27, 2008 | 34683539K | ACTIVE | CLASS - 2 | FAILURE TO PROVIDE ELEVATOR LANDING SIGN THAT SHALL READ "IN CASE OF FIRE USE STAIRS, UNLESS OTHERWISE INSTRUCTED" AT... | $5,000 | $0 | Mar 2, 2010 |
| Mar 18, 1992 | 38022350Y | RESOLVE | Non-Hazardous | 46L,74O,73O,46K,20L,1OL,35Y,39B,50Y,50Y,57O,58O,59O,55L, (74) PROPERLY REMOVE OIL CAN STORAGE & CLEAN CAR TOP. (46) R... | $375 | $0 | Jun 24, 1992 |
| Mar 18, 1992 | 38022351X | RESOLVE | Non-Hazardous | 74D,73O,10T,10L,15L,20L,35R,55L,57O,58O,59O, (74) PROPERLY STRAPS COAXAL CABLE TO WALL OR REMOVE SAME FROM MOTOR ROOM... | $375 | $0 | Jun 24, 1992 |
| Feb 4, 1991 | 38006181M | RESOLVE | Non-Hazardous | 73-O, 74-D, 74) PROPERLY STRAP COAXAL CABLE TO WALLS OR REMOVE SAME FROM MOTOR ROOM. | $1,000 | $0 | May 28, 1991 |
| Feb 4, 1991 | 38006182Y | RESOLVE | Non-Hazardous | 46-L, 17-L, 73-O, 17) CAR DOOR. | $150 | $0 | Jun 18, 1991 |