ECB violations
147-02-147-10 41 Avenue, Queens • Block 05052 • Lot 0036
46 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| May 22, 2025 | 35693808P | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD-PARKING STRUCTURE. NOTES: AT THE TIME OF INSPECTION ON AN ACTIVE PARKING STRUCTURE CONSISTING OF... | $10,000 | $10,000 | Apr 7, 2026 |
| Mar 27, 2025 | 39142944Y | RESOLVE | CLASS - 2 | IN GARAGE NEAR ENTRANCE SEVERAL AREAS OF CONCRETE CEILING SPALLING EXPOSING STEEL REBAR., REPAIR AND/OR REPLACE | $620 | $0 | Jun 3, 2025 |
| Oct 1, 2024 | 37030232R | RESOLVE | CLASS - 1 | FAILURE TO SUBMIT THE REQUIRED PARKING STRUCTURE INITIAL OBSERVATION REPORT FOR AN EXISTING PARKING STRUCTURE DOCUMEN... | $625 | $0 | Sep 2, 2025 |
| Jul 27, 2022 | 39066754L | ACTIVE | CLASS - 2 | DISCHARGE PIPES MISSING FROM STORAGE TANKS RELIEF VALVES,NO STORAGE IN BOILER ROOM, SPILL SWITCH MISSING ON DRAFTASTA... | $312 | $0 | Oct 11, 2022 |
| Feb 13, 2020 | 37018698R | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $625 | $0 | Nov 17, 2020 |
| May 1, 2018 | 38263076H | RESOLVE | CLASS - 1 | 5A10;6B10;16B1:DOOR ZONE RESTRICTOR NOT WORKING,TAKEN APART.THIS IS A SAFETY DEVICE TO ENSURE PASSENGERS SAFETY.DOOR ... | $1,250 | $0 | Jun 26, 2018 |
| Jun 13, 2017 | 35254014Z | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIRO BUILDING FACADE AND APPURTENANCES.NOTE: AT THE TIME OF INSPECTION OBSERVED IMPROPER SUPP... | $500 | $0 | Aug 1, 2017 |
| Dec 21, 2016 | 38252043H | RESOLVE | CLASS - 1 | 2X10,5L10,59M11. 2X10-OUTSIDE COMM INOPERATIVE REPAIR; 5L10-DOOR RESTORER DEFECTIVE REPAIR; 59M11-MACHINE BRAKE TAG M... | $1,000 | $0 | Feb 7, 2017 |
| Dec 21, 2016 | 38252044J | RESOLVE | CLASS - 1 | 2X10,5L10,59M11,70O2. 2X10-OUTSIDE COMM INOPERATIVE REPAIR; 5L10-DOOR RESTORE DEFECTIVE REPAIR; 59M11-MACHINE BRAKE T... | $1,000 | $0 | Feb 7, 2017 |
| Dec 19, 2014 | 38234305J | RESOLVE | CLASS - 2 | 97X10 - ONE OF TWO ELEVATORS IN BLDG NOT WORKING. RESTORE GACK TO SVC. | $250 | $0 | Mar 10, 2015 |
| Dec 13, 2014 | 38233691M | RESOLVE | CLASS - 2 | 97X10-RETURN CAR TO SERVICE. | $530 | $0 | Mar 31, 2015 |
| Feb 27, 2014 | 38230078K | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD. CONTRACTOR HAD ELEVATOR DOOR OFF, NO BARRICADES,MAINLINE NOT LOCKED OUT OR OUT AT ALL. DEVICE 4... | $2,400 | $0 | May 20, 2014 |
| Feb 27, 2014 | 38230077Z | RESOLVE | CLASS - 1 | 97X10 - RETURN ELEVATOR TO SERVICE. ONLY ELEVATOR IN BUILDING SERVING THAT SIDE CAUSING A HAZARDOUS SITUATION. | $0 | $0 | May 20, 2014 |
| Oct 16, 2013 | 38228952P | RESOLVE | CLASS - 1 | 42R09,70O02,94X10(CU),98U05. 42R09-REMOVE JUMPER WIRE FROM FUSES; 97X10-RESTORE ELEVATOR TO SERVICE SO A COMPLETE INS... | $1,000 | -$250 | Dec 9, 2013 |
| Oct 16, 2013 | 38228951N | RESOLVE | CLASS - 2 | 02L10,08V01,34O02,39O02,40O02,42A09,57H10,58H10,70O02,98U05. 02L10-OUTSIDE COMMUNCATION; 42109-REMOVE PAPER BLOCKS FR... | $500 | $0 | Dec 3, 2013 |
| Sep 20, 2011 | 38217416H | RESOLVE | CLASS - 2 | 52H11 42G11 39Y02 | $2,500 | $0 | Nov 15, 2011 |
| May 13, 2011 | 38216377J | RESOLVE | CLASS - 2 | 11D06,72M07,70O02,39Q03,77Q03.(11D06)CAR STATION UNSECURED,PULL STOP SWITCH TO SEE IT.(72M07)PROVIDE PIT STOP SWITCH ... | $0 | $0 | Jun 28, 2011 |
| Feb 17, 2011 | 34837421Y | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BUILDING NORTH ELEVATION (EXPOSURE#1) OBSERVED METAL CLAD FLASHING ON PARAPET FACADE DIS... | $250 | $0 | Nov 29, 2011 |
| Sep 20, 2010 | 36015254X | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/ CODE PROVISIONS PERIODIC INSP OF EXTERIOR... | $2,000 | $0 | Aug 18, 2011 |
| Jul 14, 2010 | 34865025K | RESOLVE | CLASS - 2 | WORK W/O A PERMIT. WORK NOTED: IN APT(S): 7K, 5A, 6A - ERECTED FULL HEIGHT PARTITIONS CREATING ADDITIONAL BEDROOMS / ... | $800 | $0 | Jul 19, 2011 |
| Jul 14, 2010 | 34865026M | RESOLVE | CLASS - 2 | RESIDENCE ALTERED FOR OCCUPANCY AS A DWELLING FOR MORE THAN THE LEGALLY APPROVED # OF FAMILIES. COQ# 139846 INDICATE ... | $1,200 | $0 | Jul 19, 2011 |
| Jul 7, 2010 | 36013697X | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCEWITH CODE PROVISIONS:PERIODIC INSPECTION OF EXT... | $800 | $0 | Aug 5, 2011 |
| Jul 7, 2010 | 34864690X | RESOLVE | CLASS - 3 | WORK W/O A PERMIT WORK NOTED IN APT 7G ERECTED FULL HEIGHT PARTITIONS CREATING BEDROOMS.REM:OBTAIN PERMIT OR RESTORE ... | $100 | $0 | Aug 31, 2010 |
| Jul 7, 2010 | 34852709Z | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG WALL(S) OR APPURTENANCES.NOTED:WINDOW A/C UNITS INSTALLED WITH LOOSE BRICKS,CANS OR WOOD BLO... | $500 | $0 | Aug 5, 2011 |
| Feb 17, 2010 | 36012178J | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/ CODE PROVISIONS PERIODIC INSP OF EXTERIOR... | $8,000 | $0 | May 18, 2010 |
| Jul 27, 2009 | 34763713R | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND OR APPROVED AMENDMENTS FOR ALT II JOB #401306895 PERMIT ... | $500 | $0 | Jul 13, 2010 |
| Feb 6, 2009 | 36008440Y | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF E... | $800 | $0 | Aug 10, 2010 |
| Oct 24, 2007 | 38169351M | RESOLVE | Non-Hazardous | 83X10,25D06,15B07,66O02,21D06,39P16. 83 RESTORE TO SERVICE SO A FULL INSPECTION CAN BE MADE. 15 INSPECTION CARD. 21 D... | $0 | $0 | Dec 11, 2007 |
| Jul 10, 2007 | 38166584J | RESOLVE | Non-Hazardous | 11L01.15M07.33O02.39P07.66O02.38O02.11L01-CALL BUTTON (11TH FLOOR) 15M07-PROVIDE CERTIFICATE OR SIGNAGE INSIDE ELEVAT... | $0 | $0 | Sep 4, 2007 |
| Jul 10, 2007 | 38166585L | RESOLVE | Non-Hazardous | 08V01.15M07.39O02.41L10.55Y13.66O02.85U05.86U05.41L10-REMOVE PAPER BLOCKS FROM RELAYS ELEVATOR DOES NOT RESPOND TO 2N... | $0 | $0 | Sep 4, 2007 |
| May 3, 2005 | 38152101Z | RESOLVE | Non-Hazardous | 55Y13/55O02/11D06 (55-O) CLEAN MACHINE- TOP OF CAR AND OIL FROM PIT. | $0 | $0 | Jun 21, 2005 |
| Feb 6, 2004 | 38144866K | RESOLVE | Non-Hazardous | 55Y13,55O02,08V01,85R05 | $180 | $0 | Mar 23, 2004 |
| Feb 6, 2004 | 38144865Z | RESOLVE | Non-Hazardous | 11D06,55Y13,55O02,08V01,85R05 | $180 | $0 | Mar 23, 2004 |
| Jul 29, 2003 | 38139495Y | RESOLVE | Non-Hazardous | 21D06,08V01,16B01,12Q03,84O02,21J01. (21) MAIN FL KEEPER (16) DOOR SLAM 4FL (84) CLEAN OIL FROM TOP CAR (21) ADJUST D... | $180 | $0 | Sep 16, 2003 |
| Jul 29, 2003 | 38139496X | RESOLVE | Non-Hazardous | 55Y13,08V01,84O02,10H11,15M07,25B07,12Q03. (84) CLEAN OIL FROM TOP CAR | $180 | $0 | Sep 16, 2003 |
| Dec 6, 2000 | 38109739Y | RESOLVE | Non-Hazardous | 57O23,11M07,13O02.11-PROVIDE LIGHT GUARDS. | $0 | $0 | Jan 23, 2001 |
| Dec 6, 2000 | 38109738M | RESOLVE | Non-Hazardous | 57O02,13O02,05I12,08V01,09H07,11M07,7402.05-VISION PANEL GLASS BROKEN 09-PROVIDE ANOTHER DOOR GIB SHOES WITH FIRE TAB... | $0 | $0 | Jan 23, 2001 |
| Sep 20, 2000 | 34238983L | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN PLUMBING AND OR APPURTENCES-HAZARDOUS-"COLD WATER PRESSURE TANK SAFETY FAILED CAUSING TANK TO OVE... | $0 | $0 | Mar 14, 2001 |
| Sep 17, 2000 | 34231514R | RESOLVE | Hazardous | FAILURE TO MAINTAIN DEFECT IS:APPROX 1000GAL METAL WATER TANK IN UTILITY ROOM LOCATION IN BASEMENT HAS EXPLODED.INTER... | $800 | $0 | Mar 14, 2001 |
| Nov 17, 1993 | 38038883N | RESOLVE | Non-Hazardous | 14M,08V,57O | $0 | $0 | Feb 1, 1994 |
| Nov 17, 1993 | 38038882L | RESOLVE | Non-Hazardous | 14M,17D,05J,08V,57O, (77) 7 FLR VISION PANEL | $0 | $0 | Feb 1, 1994 |
| Mar 9, 1992 | 38022333M | RESOLVE | Non-Hazardous | 25#;17L;36L;35R;55L; 25.INSTALLED NEW DOOR OPERATOR WITOUT A PERMIT. 17.REPLACE BROKEN GLASS TO CAR DOOR. 36.REPLACE ... | $185 | $0 | Apr 21, 1992 |
| Jan 6, 1992 | 38020652K | RESOLVE | Non-Hazardous | 09M;25L;57O; 09. 2 GIBS ON DOOR. 25.SPEED UP. | $185 | $0 | Mar 17, 1992 |
| Jan 6, 1992 | 38020651Z | RESOLVE | Non-Hazardous | 09M;35I;25L;57O; 09. 2 GIBS ON DOOR. 35. WINDOWS. 25. SPEED UP. | $185 | $0 | Mar 17, 1992 |
| Jan 31, 1991 | 38003728N | RESOLVE | Non-Hazardous | 25#,09M,11Q,08V,14M,17L,21L,25B,53M,55L,62,73#,03M. (25) INSTALLED NEWDOOR OPERATOR WITHOUT A PERMIT. (17) PROVIDE PR... | $75 | $0 | Jul 2, 1991 |
| Jan 31, 1991 | 38003727L | RESOLVE | Non-Hazardous | 17L,10#,20#,25#,11Q,73#,32M,08B,09M,36M,03Y. (17) REPLACE ALL BROKEN GLASS WITH CLEAR WIRE GLASS CAR & HALL (10)(20)(... | $435 | $0 | Apr 30, 1991 |