| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| May 9, 2018 | 35337238L | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #35317531M ISSUED ON 02/21/18 AND TO FI... | $0 | $0 | Jun 26, 2018 |
| Mar 17, 2018 | 35318043H | RESOLVE | CLASS - 2 | WORKING W/O A VARIANCE;AT TIME OF INSPECTION I OBSERVED TWO WORKERS ONSITE,ONE WAS CONDUCTING SPACKING AND ANOTHER WA... | $625 | $0 | May 1, 2018 |
| Mar 17, 2018 | 35318044J | RESOLVE | CLASS - 2 | COMPETENT PERSON;AT TIME OF INSPECTION OF A 4 STORY BUILDING,I REQUESTED TO SEE EITHER THE SUPERINTENDENT OR COMPETEN... | $2,500 | $0 | May 1, 2018 |
| Feb 21, 2018 | 35317530K | RESOLVE | CLASS - 2 | STAIR & OR FLOOR IDENTIFICATION SIGNS MISSING & OR DEFECTIVE. NOTED: AT TIME OF INSPECTION NO FLOOR SIGNS OBSERVED ON... | $0 | $0 | Apr 10, 2018 |
| Feb 21, 2018 | 35317531M | RESOLVE | CLASS - 1 | FILED A CERTIFICATE OF CORRECTION OR OTHER RELATED MATERIALS CONTAINING A MATERIAL FALSE STATEMENT. NOTE: CERTIFICATE... | $0 | $0 | Jul 17, 2018 |
| Oct 11, 2017 | 35239144L | RESOLVE | CLASS - 2 | FAILURE TO INSTITUTE SAFETY MEASURES AT TIME OF INSPECTION OBSERVED 2 WAORKERS ON A SCAFFOLD APPROX. 14 FEET OFF GROU... | $5,000 | $0 | Nov 28, 2017 |
| Oct 3, 2017 | 35239129N | RESOLVE | CLASS - 2 | MISSING SIGNS. AT TIME OF INSPECTION OBSERVED THAT THERE WAS STAIR OR FLOOR IDENTIFICATION SIGNS. THIS CONDITION CREA... | $0 | $0 | Nov 21, 2017 |
| Oct 3, 2017 | 35239128L | RESOLVE | CLASS - 2 | FAILURE TO INSTITUTE SAFETY MEASURES.@ TIME OF INSPECTION OBSERVED WORKERS ON SCAFFOLD @ BULKHEAD ROOF WITH NO FALL P... | $0 | $0 | Nov 21, 2017 |
| Oct 3, 2017 | 35239131M | RESOLVE | CLASS - 1 | GUARDRAILS. AT TIME OF INSPECTION OBSERVED WORKER ON ROOF OF BULKHEAD W/NO FALL PROTECTION OR GUARDRAIL IN PLACE. ALS... | $0 | $0 | Nov 21, 2017 |
| Oct 3, 2017 | 35239130K | RESOLVE | CLASS - 2 | NO SMOKING SIGNS.@ TIME OF INSPECTION OF 4 STORY BUILDING OBSERVED NO SMOKING SIGNS THROUGHOUT SITE.REM:PROVIDE & POS... | $800 | $0 | Nov 21, 2017 |
| Aug 29, 2017 | 35266043X | RESOLVE | CLASS - 2 | LOGS. @ THE TIME OF MY INSP. A 4 STORY BLDG @ ROOF LEVEL CONST. WORK IN PROGRESS. UPON REQUEST FOR CONST. SUPER LOGS ... | $0 | $0 | Oct 17, 2017 |
| Aug 29, 2017 | 35266042Y | RESOLVE | CLASS - 1 | DESIGNATED CONST. SUPER. @ THE TIME OF MY INSP. OF 4 STORY BLDG @ ROOFLEVEL CONST. WORK IN PROGRESS. UPON REQUEST FOR... | $10,000 | $0 | Oct 17, 2017 |
| Jul 12, 2017 | 35266869M | RESOLVE | CLASS - 1 | LOG BOOK @TIME OF INSP OF NB CURRENTLY UP TO 3RD FL & AN ACTIVE SITE W/WORKERS & CONST IN PROGRESS UPON REQUEST FOR C... | $1,600 | $0 | Aug 29, 2017 |
| Jul 12, 2017 | 35266871L | RESOLVE | CLASS - 2 | BC 3314.4 SCAFFOLD @TIME OF INSP OF ACTIVE CONST SITE UP TO 3RD FL OBSERVED WORKERS ON SCAFFOLD WHICH HAD DEFECTIVE P... | $400 | $0 | Sep 8, 2017 |
| Jul 12, 2017 | 35266870J | RESOLVE | CLASS - 2 | BC 3301.7 DESIGN DRAWINGS @TIME OF INSP OF ACTIVE CONST SITE OBSEVED OPENING PLANKED OVER W/SCAFFOLD SITTING ON TOP O... | $400 | $0 | Sep 8, 2017 |
| Jul 12, 2017 | 35266872N | RESOLVE | CLASS - 2 | FENCE @TIME OF INSP OF ACTIVE CONST SITE OBSERVED FENCE W/CHIPS CRESTING CONDITION WHERE PUBLIC COULD(RECIEVE)SPLINTE... | $0 | $0 | Sep 8, 2017 |