Skip to content

ECB violations

42-22 147 Street, Queens • Block 05374 • Lot 0057

17 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Jul 23, 2026 39557354Z ACTIVE CLASS - 2 AT THE TIME OF REINSPECTION, I OBSRVED GC HAS NOT FILE FOR A CERTIFICATE OF CORRECTION AS REQUIRED FOR CLASS 1 SUMMON... $1,250 $1,250 Oct 6, 2026
Jun 22, 2026 39555746Z ACTIVE CLASS - 1 AT THE TIME OF INSPECTION OF A SEVEN-STORY NEW BUILDING, THE BUILDING WAS OBSERVED TO BE SUBSTANTIALLY COMPLETE DESPI... $10,000 $10,000 Sep 1, 2026
May 22, 2026 39554532Z ACTIVE CLASS - 1 ATOI, I OBSERVED THAT WORK WAS CONTINUED WHILE SWO #4A23223 EXISTED SINCE 01/22/26, INDICATING STOP ALL WORK ON EXP #... $10,000 $10,000 Feb 16, 2027
Apr 17, 2026 39553122L ACTIVE CLASS - 2 AT THE TIME OF REINSPECTION FOR CLASS #1 SUMMONS ENDING IN 0821R DUE TO MISSING SCAFFOLD PERMIT, I OBSERVED SITE CLOS... $1,250 $1,250 Mar 2, 2027
Feb 19, 2026 39550821R ACTIVE CLASS - 1 ATOI I OBSERVED THAT THE GENERAL CONTRACTOR FAILED TO COMPLY WITH VIOLATION# 39548154J ISSUED ON 12/20/2025 BY NOT OB... $2,500 $2,500 Jan 26, 2027
Jan 22, 2026 39549410Y ACTIVE CLASS - 2 AT TIME OF INSPECTION @ ACTIVE 7 STORY NB. OBSERVED INSTALLED SWS @EXPO1 WITH EXPIRED PERMIT. PERMIT #Q01168491-I1-SH... $1,250 $1,250 Nov 10, 2026
Jan 22, 2026 39549411X RESOLVE CLASS - 2 OBSERVED INADEQUATE HOUSEKEEPING THROUGHOUT SITE. EXCESSIVE MATERIAL/DEBRIS STORAGE ON SEVERAL FLOORS NOT PER CODE, G... $0 $0 Nov 10, 2026
Jan 22, 2026 39549412H RESOLVE CLASS - 2 AT TIME OF INSPECTION @ ACTIVE 7 STORY NB, NOTED ON SEVERAL FLOORS EXPIRED/DEPLETED FIRE EXTINGUISHERS. FROM THE 2ND ... $625 $625 Nov 10, 2026
Jan 22, 2026 39549409R ACTIVE CLASS - 2 3309 OBS NO ADJACENT PROPERTY OR PEDESTRIAN PROTECTION @EXPO2&3. WORK ON SETBACK ABOVE ADJACENT PROPERTY NOT COMPLETE... $2,500 $2,500 Nov 10, 2026
Dec 20, 2025 39548159Z RESOLVE CLASS - 2 AT TIME OF INSPECTION OBSERVED JOB SITE CLOSED. THE SIDEWALK SHED INSTALLED ON WALKWAY AT EXPOSE ONE WITH MISSING INF... $1,250 $1,250 Sep 1, 2026
Dec 20, 2025 39548154J ACTIVE CLASS - 1 AT TIME OF INSPECTION OBSERVED 7 STORY BUILDING ROOF LEVEL UNDER CONSTRUCTION. SUPPORTED PIPE SCAFFOLD INSTALLED OVER... $5,000 $5,000 Sep 1, 2026
Dec 20, 2025 39548155L ACTIVE CLASS - 1 FAILURE TO MAINTAIN SUPPORTED PIPE SCAFFOLD. AT TIME OF INSPECTION OBSERVED SUPPORTED POPE SCAFFOLD INSTALLED AT EXPO... $5,000 $5,000 Sep 1, 2026
Dec 20, 2025 39548160X RESOLVE CLASS - 2 AT TIME OF INSPECTION OBSERVED SIDEWALK INSTALLED ON WALKWAY AT EXPOSE 1 WITH NOT MAINTAIN AS REQUIRED. SIDEWALK SHED... $2,400 $2,400 Sep 1, 2026
Aug 1, 2025 39544162L ACTIVE CLASS - 2 AT THE TIME OF INSPECTION, AT THE CORNER OF EXPOSURE 3 AND 4, OVERHEAD PROTECTION WAS NOT PROVIDED FOR THE ADJACENT P... $5,000 $5,000 Jan 26, 2027
Apr 8, 2025 39538865R RESOLVE CLASS - 2 OBSERVED SIDEWALK SHED'S VERTICAL MEMBERS MUDSILLS RESTING ON UNSTABLE SOIL ON A SLOPE CONTRARY TO CODE 3307.6.4.10 A... $2,500 $2,500 Jan 6, 2026
Apr 8, 2025 39538870L RESOLVE CLASS - 2 OBSERVED SIDEWALK SHED'S VERTICAL MEMBERS WITHOUT ANY HIGH VISIBILITY MARKINGS AS PER CODE 3307.6.4.4 CREATING A POTE... $0 $0 Jan 6, 2026
Mar 28, 2025 39143101K RESOLVE CLASS - 2 NO EN DRAWING APPROVED FROM DOB PROVIDED ON THE JOB SITE AT THE TIME OF INSPECTION., MAINTAIN/DISPLAY REQUIRED DOCUME... $1,250 $1,250 Jun 3, 2025