ECB violations
26-25 172 Street, Queens • Block 05963 • Lot 0049
12 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Nov 10, 2015 | 35155602L | RESOLVE | CLASS - 1 | FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER.CONTRACTOR WAS INSTRUCTED TO BACKFILL EXCAVATION WHICH UNDERMINED... | $0 | $0 | Feb 9, 2016 |
| Nov 10, 2015 | 35139897H | RESOLVE | CLASS - 2 | WORK WITHOUT A PERMIT.EXPIRED PERMIT.AT THE TIME OF INSPECTION THE CONTRACTOR WAS WORKING WITH AN EXPIRED PERMIT.THE ... | $0 | $0 | Dec 29, 2015 |
| Nov 10, 2015 | 35139894M | RESOLVE | CLASS - 1 | 3304.4.4 FAILURE TO PROVIDE 3 FOOT 6 INCH GUARDRAIL AROUND OPEN AND ACCESSIBLE SIDES OF EXCAVATION.NO GUARDRAILS WERE... | $0 | $0 | Feb 9, 2016 |
| Nov 10, 2015 | 35139896X | RESOLVE | CLASS - 1 | FAILURE TO NOTIFY DOB WITHIN 24-48 HOURS OF THE START OF EXCAVATION.ATTHE TIME OF INSSPECITON A 10' EXCAVATION WAS CO... | $1,200 | $0 | Feb 9, 2016 |
| Nov 10, 2015 | 35139893K | RESOLVE | CLASS - 2 | 3307.3.2 FAILURE TO PROVIDE REQUIRED LOT LINE CONSTRUCTION FENCE.NO REQUIRED LOT LINE CONSTRUCTION FENCE WAS INSTALLE... | $0 | $0 | Dec 29, 2015 |
| Nov 10, 2015 | 35139895Y | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS.PLANS INDICATE SHORING WITH RAKERS TO BE INSTALLED TO SUPPOR... | $1,000 | $0 | Feb 9, 2016 |
| Nov 10, 2015 | 35139899L | RESOLVE | CLASS - 1 | 1704.1.1 FAILURE TO FILE A SPECIAL INSPECTION STATMENT OF RESPONSIBILITY PRIOR TO PERMIT ISSUANCE AND PRIOR TO THE ST... | $1,600 | $0 | Dec 29, 2015 |
| Nov 10, 2015 | 35139898J | RESOLVE | CLASS - 1 | 104.7.1 ARCHITECTURAL/STRUCTURAL PLANS ARE NOT ADEQUATE IN THAT PLANS ARE NOT COMPLETE AND SUFFICIENT CLARITY TO INDI... | $0 | $0 | Dec 29, 2015 |
| Nov 10, 2015 | 35139892Z | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE PROTECTION AT SIDES OF EXCAVATION.AT THE TIME OF INSPECTION A SHEER CUT 10' DEEP WAS OBSERVED AT T... | $0 | $0 | Feb 9, 2016 |
| Nov 9, 2015 | 35131247J | RESOLVE | CLASS - 1 | FAIL TO PROVIDE PROTECTION OF SIDES OF EXCAVATION.NOTED:HORIZONTAL EXTENSION OF EXISTING CELLAR IN PROGRESS.EXCAVATED... | $2,400 | $0 | Feb 9, 2016 |
| Nov 9, 2015 | 35131249N | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD NOTED: EXCAVATION MORE THAN 10'DEEP WITH FOOTING REBAR NOT CAPPED AND EXTENDING VERTICALLY CREAT... | $2,400 | $0 | Feb 9, 2016 |
| Nov 9, 2015 | 35131248L | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION: NO GUARDRAILS. NOTED: OPEN PIT MOR... | $1,200 | $0 | Feb 9, 2016 |