ECB violations

160 Street, Queens • Block 06726 • Lot 0070

61 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Mar 16, 2026 35722186J ACTIVE CLASS - 2 RE-ISSUE #35725586M. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: SMOKE DOORS REMOVED AT MAIN ENTRAN... $3,125 $0 Apr 20, 2026
Sep 18, 2025 35725586M ACTIVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: SMOKE DOORS REMOVED ON MAIN ENTRANCE OF SCHOOL. REMEDY:... $1,250 $0 Oct 22, 2025
Sep 18, 2025 35725584Z ACTIVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANENR. NOTED: MISSING FIRE STOPPING AT GAS NO FIRESTOPPING PER BC 712... $1,250 $0 Oct 22, 2025
Sep 18, 2025 35725585K RESOLVE CLASS - 2 EMERGENCY SIGNS AT ELEVATOR CALL STATIONS MISSING DEFECTIVE OR NON-COMPLIANT WITH SECTION REQUIREMENTS. NOTED: MISSIN... $625 $0 Oct 22, 2025
Sep 18, 2025 35725583R RESOLVE CLASS - 2 EXIT DOOR NOT SELF-CLOSING. NOTED: EMERGENCY EXIT DOORS NOT SELF-CLOSING IN VARIOUS LOCATIONS(1) DOOR MAIN ENTRANCE, ... $625 $0 Oct 22, 2025
Mar 30, 2021 35548574K RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NO FIRE STOPPING PER BC 712.3;27-345. AT BASEMENT LEVEL OLD ELECTR... $1,250 $0 Jul 13, 2021
Mar 30, 2021 35548573Z RESOLVE CLASS - 2 REISSUE#35433859Y DATE OF ISSUE 7-01-2021 EXIT DOOR NOT SELF CLOSING PROPERLY. AT BASEMENT LEVEL EXIT#6 & 7 AT 1ST FL... $1,562 $0 Jul 13, 2021
Apr 23, 2019 39002278R RESOLVE CLASS - 2 EASCO BOILER MODEL# FST-200. MISSING HAND VALVE BEFORE ANTI-SIPHON AT OIL TANK. RESOLVE VIOLATING CONDITION AND SUBMI... $0 $0 Apr 23, 2019
Apr 23, 2019 39002277P RESOLVE CLASS - 2 EASCO BOILER MODEL# FST-200. MISSING HAND VALVE BEFORE ANTI-SIPHON AT OIL TANK. RESOLVE VIOLATING CONDITION AND SUBMI... $0 $0 Apr 23, 2019
Mar 20, 2019 35384049Y RESOLVE CLASS - 2 EXIT DOOR NOT SELF-CLOSING. NOTED: AT EXIT #6 & 7 THE DOORS ARE NOT CLOSING PROPERLY. REMEDY: REPAIR/REPLACE DOOR $0 $0 Jun 25, 2019
Mar 20, 2019 35384048M RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:ILLUMINATION FOREXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER ... $0 $0 Jun 25, 2019
Feb 13, 2019 32098378Z RESOLVE CLASS - 2 B254 EASCOBOILER MDL#FST-200: 50AI HONEYWELL SOLONID VALVE LEAKING WATER ON FEED LINE. RMDY: RESOLVE VIOLATING CONDIT... $0 $0 Jun 25, 2019
Mar 28, 2018 35325981J RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:ILLUMINATION FOREXITS EXIT DISCHARGES AND PUBLIC CORRIDORS PER ... $0 $0 Jul 3, 2018
Apr 19, 2017 35253192R RESOLVE CLASS - 2 REISSUE #35221127Y FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: (EXERIOR) ON THE ROOF I OBSEVED A CLOGGED D... $0 $0 Jul 11, 2017
Nov 7, 2016 35221128X RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3;27-345. NOTED: MISSING FIRE STOPPING... $0 $0 Jan 10, 2017
Nov 7, 2016 35221127Y RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: A CLOGGED DRAIN WAS OBSERVED AT ROOF,APPROX 7'X7'X12" WATER... $0 $0 Jan 10, 2017
Nov 7, 2016 35221130P RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: BROKEN OR DEFECTIVE CEILING LIGHT FIXTURE WAS OBSERVED AT R... $0 $0 Jan 10, 2017
Nov 7, 2016 35221131R RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER: LACK OF EMERGENCY LIGHTING FOR EXITS,EXIT DISCHARGES & PUBLIC CORR... $0 $0 Jan 10, 2017
Nov 7, 2016 35221129H RESOLVE CLASS - 2 EXIT DOOR NOT SELF CLOSING. NOTED: AT 1ST FL,STAIRCASE'H',DOOR THAT NOT CLOSE PROPERLY WAS OBSERVED. REMEDY: REPAIR/R... $0 $0 Jan 10, 2017
Dec 31, 2015 35168699J RESOLVE CLASS - 2 BC3307.6.5 FAILURE TO MAINTAIN ADEQUATE ILLUMINATION BENEATH SIDEWALK SHED AS REQUIRED BY CODE. NOTED: SIDEWALK SHED ... $400 $0 Feb 16, 2016
Apr 23, 2015 35120597X RESOLVE CLASS - 2 RE-ISSUE#35086016M FAILURE TO MAINTAIN BLDG CODE-COMPLIANT:LACK OF EMERGENCY LIGHTING PER BC 1006;27-542 NOTED:INOPER... $0 $0 Jun 16, 2015
Apr 23, 2015 35120596Y RESOLVE CLASS - 2 RE-ISSUE#35086013R EXIT DOOR NOT SELF CLOSING.NOTED:@1A,BROKEN DOOR CLOSER ON EXIT DOOR 1ST FL STAIRWAY A.REM:COMPLY ... $0 $0 Jun 16, 2015
Mar 10, 2014 35086018X RESOLVE CLASS - 2 EXIT DOOR NOT SELF CLOSING. AT TRANSPORTABLE UNITS T1 TO T2, INTERIOR FIRE DOOR IS RACKED TO FRAME AND NOT PLUMB, PRE... $0 $0 Jun 3, 2014
Mar 10, 2014 35086017Y RESOLVE CLASS - 2 OCCUPANCY CONTRARY. 3 CARS PARKED IN SCHOOL YARD HANDBALL COURT. CERTIFICATE OF OCCUPANCY # Q168633 DOES NOT INDICATE... $0 $0 Jun 3, 2014
Mar 10, 2014 35086014Z RESOLVE CLASS - 2 EXCESSIVE COMBUSTIBLES. COMBUSTIBLE DECORATIONS HANGING WALL TO WALL AND ON CONDUITS AT ENTRY CORRIDOR AND CAFETERIA.... $0 $0 Jun 3, 2014
Mar 10, 2014 35086016M RESOLVE CLASS - 2 EMERGENCY LIGHTING INOPERATIVE. AT 1ST FLOOR CAFETERIA & AUDITORIUM, EMERGENCY LIGHTING WITH BATTERY BACK UP IS NOT W... $0 $0 Jun 3, 2014
Mar 10, 2014 35086015K RESOLVE CLASS - 1 EXIT DOORS SWING AGAINST THE FLOW OF EGRESS. AT 1ST FL, THE 3 DOORS AT STAIR "A" & 3 DOORS AT STAIR "B" SWING AGAINST... $0 $0 Jun 3, 2014
Mar 10, 2014 35086013R RESOLVE CLASS - 2 EXIT DOOR NOT SELF CLOSING. AT 1ST FLOOR EXIT 'A', BROKEN DOOR CLOSER. REMEDY: REPLACE DOOR CLOSER. $0 $0 Jun 3, 2014
Jul 9, 2013 35022671X RESOLVE CLASS - 2 REISSUE: 34981889X 2' FEET HIGH CONCRETE WALL BY THE MAIN ENTRANCE IS SPALLING & CRUMBLING. REMEDY: REPAIR &/OR REPLA... $0 $0 Sep 17, 2013
Jun 15, 2012 34981890N RESOLVE CLASS - 2 EXIT SIGN NOT ILLUMINATED. AT FORTH FLR STAIRWAY B & MAIN ENTRY NO ILLUMINATED EXIT SIGN. REM:INSTALL ILLUMINATED EXI... $0 $0 Aug 14, 2012
Jun 15, 2012 34981889X RESOLVE CLASS - 2 THE CONCRETE FENCE FOUNDATION WALL APPROXIMATELY 2' FEET IS SPALLING &CRUMBLING LOCATED AT THE CORNER OF 159 STREET &... $0 $0 Aug 14, 2012
Jun 24, 2009 34792693L RESOLVE CLASS - 2 REISSUE 34645792R. THE PLASTER IS SPALLING OFF THE CEILING LOCATED IN ROOM 120 & 121 ON THE 1ST FLR LEVEL. REMEDY: RE... $0 $0 Sep 15, 2009
Jun 24, 2009 34792694N RESOLVE CLASS - 2 THE ELECTRICAL ROOM IS LACKING FIRESTOPPING AT THE PIPE PENETRATION ATCELLAR LEVEL. REMEDY: PROVIDE/MAINTAIN FIRESTOP... $0 $0 Sep 15, 2009
Jun 24, 2009 34792695P RESOLVE CLASS - 2 THE CONCRETE BLOCK WALL IS VERTICALLY CRACKED LOCATED IN THE AUDITORIUM STAGE AT BASEMENT LEVEL. REMEDY: REPAIR/REPLA... $0 $0 Sep 15, 2009
Jun 24, 2009 34792696R RESOLVE CLASS - 2 THE EXTERIOR RETAINING WALL IS CRACKED AND MISSING SOME SECTION OF THECONCRETE LEAVING EXPOSED REBARS LOCATE ADJACENT... $0 $0 Sep 15, 2009
Jun 24, 2009 34792692J RESOLVE CLASS - 2 REISSUE 34645795M. THE PLASTER IS SPALLING LOCATED AT RM 413 ON THE 4TH FLR LEVEL. REMEDY: REPAIR/REPLACE PLASTER ON ... $0 $0 Sep 15, 2009
Jun 25, 2008 34645793Z RESOLVE Hazardous REISSUE: 34577905M BRICK FACADE HAS BECOME POROUS AND ALLOWING RAIN WATER TO ENTER THE BUILDING CAUSING INTERIOR DAMA... $0 $0 Sep 9, 2008
Jun 25, 2008 34645792R RESOLVE Hazardous REISSUE: 345779064 PLASTER ON THE WALL & CEILING IS SPALLING & CRACKED LOCATED IN ROOM 120 & 121 ON THE 1ST FLR LEVEL... $0 $0 Sep 9, 2008
Jun 25, 2008 34645795M RESOLVE Hazardous PLASTER ON THE CEILING IS CRACKED LOCATED IN ROOM 413 4TH FLR LEVEL. REMEDY; REPAIR PLASTER ON CEILING. $0 $0 Sep 9, 2008
Jun 25, 2008 34645794K RESOLVE Hazardous EXIT STAIRWAY "A" & "B" DOORS ARE MISSING AT THE CAFETERIA EXIT 1ST FLR LEVEL. REMEDY: REPLACE MISSING EXIT DOORS. $0 $0 Sep 9, 2008
Jun 26, 2007 34577905M RESOLVE Hazardous REISSUE:34517325L ROOF HAS BECOME POROUS & ALLOWING RAIN WATER INTO THE BLDG CAUSING INTERIOR DAMAGES IN RM 120 & 121... $0 $0 Aug 14, 2007
Jun 20, 2007 34577906Y RESOLVE Hazardous REISSUE:34517326N PLASTER IS SPALLING & CRACKED ON THE WALL & CEILING IN CLASSROOM 120 & 121 ON THE 1ST FL.REMEDY:PLA... $0 $0 Aug 14, 2007
Mar 30, 2006 34517325L RESOLVE Hazardous FAILURE TO MAINTAIN EXTERIOR OF BLDG ROOF N.W ROOF LEAK INTO RM 120 & 121 LOCATION RM 121 AND 120 CEILING AND WALL. R... $0 $0 Jun 6, 2006
Mar 30, 2006 34517326N RESOLVE Hazardous FAILURE TO MAINTAIN INTERIOR WALL AND CEILING IN CLASS RM 120 AND 121.REMEDY:REPAIR DEFECT WALL AND CEILING $0 $0 Jun 6, 2006
Mar 3, 2003 34383078M RESOLVE Non-Hazardous FAILURE TO MAINTAIN NOTED AT FIRST FLOOR BLOWER ROOM STRUCTURAL CRACKS THROUGHOUT WALLS AND CEILING ALSO NOTED EIGHT ... $0 $0 May 13, 2003
Mar 3, 2003 34383080L RESOLVE Non-Hazardous FAILURE TO MAINTAIN NOTED IN ROOM 409 AT CEILING BY PIPE DUE TO SUSTAWNED WATER DAMAGE PLASTER WAS CRACKED PEELED AND... $0 $0 May 13, 2003
Mar 3, 2003 34383077K RESOLVE Non-Hazardous FAILURE TO MAINTAIN NOTED IN GYMNASIUM ON EAST WALL BY WINDOWS DUE TO SUSTAINED WATER DAMAGE CONCRETE HAS BECOME PORO... $0 $0 May 13, 2003
Mar 3, 2003 34383076Z RESOLVE Non-Hazardous FAILURE TO USE PANIC HARDWARE WHERE REQUIRED BY LAW NOTED IN GYMNASIUM WHERE OCCUPANCY LOAD IS 300X DOOR KNOBS IN USE... $0 $0 May 13, 2003
Mar 3, 2003 34383075R RESOLVE Non-Hazardous USE PANIC HARDWARE WHERE REQUIRED BY LAW NOTED IN CARETERIA OCCUPANCY LOAD IS 300X DOOR KNOBS IN USE AT EXITS 3,4,5 A... $0 $0 May 13, 2003
Mar 3, 2003 34383074P RESOLVE Non-Hazardous PANIC HARDWARE INOPERATIVE NOTED AT AUDITORIUM RIGHT OF STAGE EXIT 9 PANIC HARDWARE DOES NOT RELEASE AT MAX 15 LBS OF... $0 $0 May 13, 2003