179-04 80 Drive, Queens
Queens • Block 07235 • Lot 0017 • Zip: 11432
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 3 days ago- Grand Central 61 min 16 walking, 45 riding
- Times Square 62 min 16 walking, 46 riding
- Penn Station 64 min 16 walking, 48 riding
- Union Square 65 min 16 walking, 49 riding
- Fulton Street 71 min 16 walking, 55 riding
- Downtown Brooklyn 72 min 16 walking, 56 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Railroad
Bus
Places nearby
Activity
Sales, filings, permits and violations from every dataset, in one order.
2024
-
DOB violation Jul 5, 2024
C-CONSTRUCTION OTHER OPTIONAL
PART DEMO/ALT WRK OBSRVD.ENGR EVAL RPT SGND&SEALD.BY PETER.STROH,PE, 3/21/24,INDICATES FREESTAND WALLS AT EXP 2&4.& R...
-
CLASS - 1
UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION# 39108952P ISSUED ON 03/...
-
CLASS - 1
UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION# 39108951N ISSUED ON 03/...
-
DOB violation Apr 18, 2024
C-CONSTRUCTION OTHER OPTIONAL
PART DEMO/ALT WRK OBSRVD.ENGR EVAL RPT SGND&SEALD.BY PETER STROH,PE, 3/21/24,INDICATES FREESTAND WALLS AT EXP 2&4.& R...
-
CLASS - 1
ATOI, OBSERVED GAS BEING SUPPLIED TO PROPERTY WITHOUT AUTHORIZATION. GAS PIPING HAS BEEN DEMOED ON ALL FLOORS. GAS ME...
-
CLASS - 2
ATOI, OBSERVED UNSAFE SITE CONDITIONS - MISSING GUARDRAILS AROUND FOUNDATION AND 1ST FLOOR, NO CONTROLLED ACCESS ZONE...
-
CLASS - 1
ATOI, FAILURE TO HAVE ALTERED PLUMBING SYSTEM TESTED AFTER INTERIOR GAS PIPE REMOVAL AND ALTERATION. THIS POSES AN IM...
-
CLASS - 2
ATOI, OBSERVED AT EXPO #1, #2 #3 AND #4 LEANING, WARPED GREEN CONSTRUCTION PANELS, VISIBLE OPEN 2+ INCH GAPS, MISSING...
-
DOB violation Mar 15, 2024
C-CONSTRUCTION OTHER OPTIONAL
ATOI, OBSERVED FULL REMOVAL OF INTERIOR POWER, LIGHTING AND SWITCHING AND ELECTRICAL WIRING. NO ELECTRICAL PERMIT FILED.
-
DOB violation Mar 15, 2024
IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL
REMEDY- INSTALL CONSTRUCTION FENCE APPROX 95LF( 80FT ALONG EXPO #2 &15 FT ALONG EXPO#3 TO PROTECT ANS SAFEGUARD ALL P...
-
DOB violation Mar 15, 2024
C-CONSTRUCTION OTHER OPTIONAL
ATOI, OBSERVED AT EXPO #2 AND #4, FREE-STANDING WALLS AT 1ST FLOOR LEVEL LEFT UNSUPPORTED. MISSING WALLS AT EXPO # 1 ...
-
DOB violation Mar 15, 2024
C-CONSTRUCTION OTHER OPTIONAL
ATOI, OBSERVED REMOVAL OF INTERIOR WATER WASTE, VENT AND GAS PIPING WITHOUT FILING A PERMIT.
2023
2022
2018
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Recent Building Permits
Owner information from recent DOB NOW filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records