Maintenance code violations
123-04 Hillside Avenue, Queens • Block 09277 • Lot 0051
45 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| Nov 29, 2023 | C | NOV CERTIFIED LATE | § 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STOR... | 2 | Nov 29, 2023 |
| Nov 29, 2023 | C | NOV CERTIFIED LATE | § 27-2029 ADMIN. CODE: PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2,... | 2 | Nov 29, 2023 |
| Nov 29, 2023 | B | INVALID CERTIFICATION | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STOR... | 2 | Jan 3, 2024 |
| Nov 20, 2023 | A | NOV SENT OUT | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT , 1st DOOR FRAME FROM WEST A... | 2 | Feb 23, 2024 |
| Nov 20, 2023 | A | NOV SENT OUT | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT , 2nd DOOR FROM SOUTH AT WES... | 2 | Feb 23, 2024 |
| Nov 20, 2023 | A | NOV SENT OUT | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION , 1st RADIATOR FROM SOUTH AT WEST WALL IN THE 4th ... | 2 | Feb 23, 2024 |
| Nov 20, 2023 | C | VIOLATION DISMISSED | § 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF EXTREMLY HOT WATER EXCEEDING THE MAXIMUM ALLOWABLE TEMPERATUR... | 2 | Nov 26, 2023 |
| Nov 20, 2023 | B | VIOLATION DISMISSED | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER SASH SPRING BALANCE AT 2ND WINDOW FROM WEST A... | 2 | Dec 25, 2023 |
| Nov 20, 2023 | B | VIOLATION DISMISSED | § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT EAST WALL AT P... | — | Dec 25, 2023 |
| Nov 20, 2023 | B | VIOLATION DISMISSED | § 27-2073 ADM CODE - PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES NO GAS AT THE COOKING RANGE. TENANT RESPONSIBL... | 2 | Dec 25, 2023 |
| Nov 20, 2023 | B | VIOLATION DISMISSED | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER SASH SPRING BALANCE AT 1ST WINDOW FROM NORTH ... | 2 | Dec 25, 2023 |
| Nov 20, 2023 | C | VIOLATION DISMISSED | § 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF UNCAPPED RADIATOR SHUTOFF VALVE AT WEST WALL IN THE 3rd ROOM ... | 2 | Nov 26, 2023 |
| Nov 20, 2023 | C | VIOLATION DISMISSED | § 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF FREE STANDING RADIATOR AT SOUTH WALL IN THE 3rd ROOM FROM NOR... | 2 | Nov 26, 2023 |
| Nov 20, 2023 | B | VIOLATION DISMISSED | § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE APPROX 8 SQFT OF BROKEN AND LOOS... | 2 | Dec 25, 2023 |
| Nov 20, 2023 | C | NOV SENT OUT | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS ... | 2 | Dec 14, 2023 |
| Nov 20, 2023 | C | NOV SENT OUT | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS ... | 2 | Dec 14, 2023 |
| Nov 20, 2023 | C | NOV SENT OUT | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS ... | 2 | Dec 14, 2023 |
| Nov 20, 2023 | B | VIOLATION DISMISSED | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICA... | 2 | Dec 25, 2023 |
| Nov 20, 2023 | C | NOV SENT OUT | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT ... | 2 | Dec 14, 2023 |
| Nov 20, 2023 | A | NOV SENT OUT | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT , BASEBOARD AT NORTH WALL, 1... | 2 | Feb 23, 2024 |
| Nov 8, 2023 | B | NOV CERTIFIED LATE | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd S... | 2 | Dec 13, 2023 |
| Nov 8, 2023 | C | VIOLATION CLOSED | § 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER EXCEEDS THE MAXIMUM OPERATING ALLOWANCE OF... | 2 | Nov 14, 2023 |
| Nov 8, 2023 | C | VIOLATION CLOSED | § 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF UNCAPPED VALVE AT STEAM RISER AT WEST WALL IN THE 2nd ROOM FR... | 2 | Nov 14, 2023 |
| Nov 8, 2023 | B | VIOLATION DISMISSED | § 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT THE BATHTUB IN THE BATHROOM LOCATED AT APT 2, 2nd... | 2 | Dec 13, 2023 |
| Nov 8, 2023 | B | VIOLATION DISMISSED | § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE PRIVA... | 2 | Dec 13, 2023 |
| Nov 8, 2023 | B | VIOLATION DISMISSED | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICA... | 2 | Dec 13, 2023 |
| Nov 8, 2023 | B | VIOLATION DISMISSED | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT NORTH WALL IN THE 1st ROOM FRO... | 2 | Dec 13, 2023 |
| Nov 8, 2023 | B | VIOLATION DISMISSED | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICA... | 2 | Dec 13, 2023 |
| Nov 8, 2023 | B | NOV CERTIFIED LATE | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STOR... | 2 | Dec 13, 2023 |
| Nov 6, 2023 | C | NOV CERTIFIED LATE | § 27-2029 ADMIN. CODE: PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE 3rd ROOM FROM NORTH AT WEST LOCATE... | 2 | Nov 4, 2023 |
| Nov 6, 2023 | C | VIOLATION CLOSED | § 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF CONSISTING OF SCALDING HOT WATER IN THE BATHROOM LOCATED AT A... | 2 | Nov 12, 2023 |
| Nov 6, 2023 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE PRIVATE H... | 2 | Nov 12, 2023 |
| Nov 3, 2023 | C | VIOLATION CLOSED | § 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER EXCEEDING THE MAXIMUM TEMPERTURE OF130 DEG... | 2 | Nov 9, 2023 |
| Nov 3, 2023 | C | NOV CERTIFIED LATE | § 27-2029 ADMIN. CODE: PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE 3rd ROOM FROM NORTH AT WEST LOCATE... | 2 | Nov 3, 2023 |
| Nov 3, 2023 | B | VIOLATION DISMISSED | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE 4TH, 5TH, 6TH, AND 7TH WOODEN THREAD FROM BOTTOM AT... | — | Dec 8, 2023 |
| Nov 2, 2023 | B | VIOLATION DISMISSED | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL LIGHTING FIXTURE AT CEILING IN THE 1st R... | 2 | Dec 7, 2023 |
| Nov 2, 2023 | C | VIOLATION CLOSED | § 27-2029 ADMIN. CODE: PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2,... | 2 | Nov 2, 2023 |
| Nov 2, 2023 | B | NOV CERTIFIED LATE | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STOR... | 2 | Dec 7, 2023 |
| Nov 2, 2023 | C | VIOLATION CLOSED | § 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER IN THE BATHROOM LOCATED AT APT 2, 2nd STOR... | 2 | Nov 8, 2023 |
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| Nov 2, 2023 | B | VIOLATION DISMISSED | § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT CEILING IN THE... | 2 | Dec 7, 2023 |
| Nov 2, 2023 | B | VIOLATION DISMISSED | § 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2,... | 2 | Dec 7, 2023 |
| Nov 2, 2023 | C | VIOLATION CLOSED | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICA... | 2 | Nov 8, 2023 |
| Nov 2, 2023 | C | VIOLATION CLOSED | § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE PRIVA... | 2 | Nov 8, 2023 |