ECB violations
Ps 161, Queens • Block 09491 • Lot 0001
40 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Feb 27, 2026 | 35728889N | ACTIVE | CLASS - 2 | RE-ISSUE #35692026X. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MAWNER. NOTED: 2ND FLR CAFETERIA KITCHEN SLOP SIN... | $3,125 | $0 | Mar 17, 2026 |
| Feb 27, 2026 | 35728890K | ACTIVE | CLASS - 2 | RE-ISSUE #35691874Y. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: CRACKS IN CMU INTERIOR WALLS AT ST... | $3,125 | $0 | Mar 17, 2026 |
| Feb 27, 2026 | 35728891M | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: INTERIORSMOKE DOORS DO NOT SELF-CLOSE PROPERLY, AT 2ND ... | $1,250 | $0 | Mar 17, 2026 |
| Aug 21, 2025 | 39157958R | ACTIVE | CLASS - 2 | KEWANEE BOILER#2 HAS BOILER FLANGE LEAKING@TOP OF BOILER+KING VALVE LEAKING ONTO BURNER+MANHOLE LEAKING+UPPER RIGHT H... | $1,250 | $0 | Aug 25, 2025 |
| Aug 21, 2025 | 39157957P | ACTIVE | CLASS - 3 | KEWANEE BOILER#1 WATER FEED PUMP#1 LEAKING+#1 HW RE CIRCULATOR SEIZED UP+WASHOUT PLUGS IN WATER COLUMNS LEAKING+@TOP ... | $500 | $0 | Aug 25, 2025 |
| Mar 25, 2025 | 35692026X | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED 2ND FL CAFETERIA KITCHEN STOP SINK LEAKING WATER TO MAIN ... | $1,250 | $0 | Jul 8, 2025 |
| Mar 25, 2025 | 35691874Y | ACTIVE | CLASS - 2 | REISSUE#35678943M FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED CRACKS IN CMU INTERIOR WALLS AT STAIR A... | $3,125 | $0 | Jul 8, 2025 |
| Mar 25, 2025 | 35692025Y | RESOLVE | CLASS - 2 | REISSUE#35678942K EXIT DOOR NOT SELF-CLOSING.NOTED EXTERIOR DOORS AT EXIT#4 & 5 NOT SELF CLOSING PROPERLY.CORRODED DO... | $1,562 | $0 | Jul 8, 2025 |
| Apr 16, 2024 | 35678943M | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:SEVERAL VERTICAL STEP CRACKS AT INTERIOR CMU WALLS AT STA... | $625 | $0 | Jul 3, 2024 |
| Apr 16, 2024 | 35678942K | RESOLVE | CLASS - 2 | EXIT DOOR NOT SELF-CLOSING.NOTED:EXTERIOR DOOR AT EXIT#4 RUSTED WITH HOLE ON THE BOTTOM.ADDITIONALLY EXIT#5 DOOR GETS... | $625 | $0 | Jul 3, 2024 |
| Feb 9, 2021 | 39035991N | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... | $1,250 | $0 | Feb 22, 2021 |
| Feb 9, 2021 | 39035990L | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... | $1,250 | $0 | Feb 22, 2021 |
| Aug 5, 2019 | 39007102X | ACTIVE | CLASS - 2 | FOUND 1 KEWANEE 7L282XL DUAL FUEL FIRED STEAM BOILER OVER 8' MISSING LADDER AND WORK PLATFORM. ALL DOORS REQUIRE A SH... | $0 | $0 | Aug 12, 2019 |
| Aug 5, 2019 | 39007101Y | ACTIVE | CLASS - 2 | FOUND 1 KEWANEE 7L282XL DUAL FUEL FIRED STEAM BOILER OVER 8' HIGH MISSING LADDER AND WORK PLATFORM. ALL BOILER ROOM D... | $0 | $0 | Aug 12, 2019 |
| Dec 15, 2017 | 35282496Z | ACTIVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO #35293093H ISSUED ON 11/05/17& TO FILE A CERT OF CORREC... | $4,000 | $0 | Feb 20, 2018 |
| Sep 16, 2015 | 35147339N | RESOLVE | CLASS - 2 | — | $0 | $0 | Oct 27, 2015 |
| Mar 31, 2014 | 35085224M | RESOLVE | CLASS - 2 | DEFECTIVE FIRE DAMPERS @ BSMT BOILER ROOM NOT OPERATIONAL @ TIME OF INSP.REM:REPAIR/REPLACE LOUVERS. | $0 | $0 | Jun 3, 2014 |
| May 3, 2012 | 34954510Z | RESOLVE | CLASS - 2 | REISSUE 34918568N. ROOF HAS BECOME POROUS ALLOWING WATER TO PENETRATE INTO RM 411 & CORRIDOR AT 3RD FLR OUTSIDE AUDIT... | $0 | $0 | Jun 19, 2012 |
| May 3, 2012 | 34954511K | RESOLVE | CLASS - 2 | REISSUE 34918567L. WATER PENETRATING THROUGH EXTERIOR WALL NEAR WINDOWS IN ROOMS 340,342,410,440 AND 442. REMEDY: DET... | $0 | $0 | Jun 19, 2012 |
| May 3, 2012 | 34954509L | RESOLVE | CLASS - 2 | REISSUE 34918570M. WATER PENETRATION AT FOUNDATION WALL ALLOWING WATERINTO RMS B02 & B04. REMEDY: WATER PROOF FOUNDAT... | $0 | $0 | Jun 19, 2012 |
| Jun 20, 2011 | 34918569P | RESOLVE | CLASS - 2 | OCCUPANCY CONTRARY TO DOB RECORDS 3RD FLOOR CORRIDOR ADJACENT TO AUDITORIUM SET UP AS CLASS ROOM W/ DESK TABLES CHAIR... | $0 | $0 | Aug 2, 2011 |
| Jun 20, 2011 | 34918570M | RESOLVE | CLASS - 2 | FOUNDATION PENETRATION THE FOUNDATION HAS BECOME POROUS ALLOWING RAIN WATER TO PENETRATE INTO ROOMS B02 & B04 AT GYM ... | $0 | $0 | Aug 2, 2011 |
| Jun 20, 2011 | 34918567L | RESOLVE | CLASS - 2 | REISSUE #34792171Y EXTERIOR WALL PENETRATION THE EXTERIOR WALLS BECOME POROUS ALLOWING WATER TO PENETRATE INTO CLASSR... | $0 | $0 | Aug 2, 2011 |
| Jun 20, 2011 | 34918568N | RESOLVE | CLASS - 2 | ROOF LEAK THE ROOF HAS BECOME ALLOWING RAIN WATER TO PENETRATE INTO ROOM 411 & 3RD FLOOR AUDITORIUM CORRIDOR REM: WAT... | $0 | $0 | Aug 2, 2011 |
| Jun 19, 2009 | 34792167L | RESOLVE | CLASS - 2 | WINDOW GRATES LOCATED AT SOUTHSIDE PLAY YARD NOT SECURELY FASTENED DOWN TO FRAME BOUNCE UP AND DOWN AS YOU WALK OVER ... | $0 | $0 | Sep 15, 2009 |
| Jun 19, 2009 | 34792171Y | RESOLVE | CLASS - 2 | WATER PENETRATION INTO ROOMS AT SOUTH SIDE OF BLDG WHERE CORNER WINDOWS MEET BRICK BLDG ALL FLRS. REMEDY: WATERPROOF. | $0 | $0 | Sep 15, 2009 |
| Jun 19, 2009 | 34792168N | RESOLVE | CLASS - 3 | PROTECTIVE WINDOW GUARDS AT FIRST FLR RUSTED PITTED SHOWING SIGNS OF DETERIORATION. REMEDY: REMOVE RUST REPAINT GUARD... | $0 | $0 | Sep 15, 2009 |
| Jun 19, 2009 | 34792170M | RESOLVE | CLASS - 2 | PLASTER DAMAGE ON WALL ROOM 415 AND CEILING B8. REMEDY: REPAIR WALLS AND CEILING. | $0 | $0 | Sep 15, 2009 |
| Jun 19, 2009 | 34792169P | RESOLVE | CLASS - 2 | WATER PENETRATION AT CEILING ROOM 415 AND B8. REMEDY: WATERPROOF BLDG. | $0 | $0 | Sep 15, 2009 |
| Jun 19, 2007 | 34607668M | RESOLVE | Non-Hazardous | STAIR IDENTIFICATION SIGNS MISSING WITHIN STAIRWELLS-STAIR SIDE.REMEDY:INSTALL SIGNS. | $0 | $0 | Nov 13, 2007 |
| Jun 19, 2007 | 34607669Y | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN CORRIDOR CEILING,FRONTING 3FL AUDITORIUM ROOM 301-UPHILL END.REMEDY:REPAIR/REPLACE DEFECTIVE CEIL... | $0 | $0 | Nov 13, 2007 |
| May 24, 2005 | 34482205J | RESOLVE | Non-Hazardous | WATER PENETRATION THROUGH ROOF INTO CORRIDOR IN FRONT OF ROOM #301.REMEDY:STOP WATER PENETRATION MAKE ALL NECESSARY R... | $0 | $0 | Aug 2, 2005 |
| May 24, 2005 | 34482204H | RESOLVE | Non-Hazardous | WATER PENETRATION THROUGH EXTERIOR WALL INTO CLASSROOM #410.REMEDY:STOP WATER PENETRATION MAKE ALL NECESSARY REPAIRS | $0 | $0 | Aug 2, 2005 |
| May 24, 2005 | 34482206L | RESOLVE | Non-Hazardous | NO CAPACITY SIGN POSTED @3RD FLOOR AUDITORIUM.REMEDY:POST APPROVED CAPACITY SIGN | $0 | $0 | Aug 2, 2005 |
| Jan 20, 2004 | 34422206R | RESOLVE | Non-Hazardous | USE OF ILLEGAL HARDWARE;EXIT DOORS EQUIPPED WITH SLIDE BOLTS LOCK IN OPEN POSITION:LOCATION OF DOORS (1)ENTRANCE AT 1... | $0 | $0 | Mar 30, 2004 |
| Jan 20, 2004 | 34422205P | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN DEFECTS:LEAKY ROOF OVER ROOM 415 4TH FLOOR NORTH EAST.REMEDY:MAKE ALL NECESSARY REPAIRS. | $0 | $0 | Mar 30, 2004 |
| Jan 20, 2004 | 34422207Z | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN;DEFECT IS INPROPER SLOPED WALKWAY CAUSING FLOODINGENTRANCE AREA.AND BOILER ROOM IN THE CELLAR AT ... | $0 | $0 | Mar 30, 2004 |
| Feb 25, 2003 | 34382902R | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BUILDING. DEFECT: SIDEWALK (124 SN SIDE) WITH IMPROPER SLOPE CAUSING FLOOD IN SCHOOL (ENTRANCE AR... | $0 | $0 | May 13, 2003 |
| Apr 16, 2002 | 34302982N | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE ADEQUATE 3 INCH HIGH ALPHABETIC LETTER OF IDENTIFICATION (NOT NUMBER) FOR ELEVATOR BANK ON FLOOR 1... | $0 | $0 | Jun 18, 2002 |
| Apr 16, 2002 | 34302980J | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE EMERGENCY POWER TO LIGHTING FACILITY MOSTLY WITHIN STAIR AND CORRIDOR ON FLOOR 1 TO 4. DUE TO BACK... | $0 | $0 | Jun 18, 2002 |