ECB violations
89-32 162 Street, Queens • Block 09760 • Lot 0061
30 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Sep 29, 2025 | 39161736N | RESOLVE | CLASS - 2 | FOUND WATER HEATER MODEL# D100-199 SERIAL# F8-3225 LEAKING, MAINTAIN BOILER; CORRECT VIOLATING CONDITION AND SUBMIT A... | $1,250 | $1,250 | Dec 9, 2025 |
| Sep 29, 2025 | 39161789R | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 ... | $0 | $0 | Dec 9, 2025 |
| Sep 29, 2025 | 39161788P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED GARAGE PALS OBSTRUCTING PASSAGEWAY IN STAIRWELL. LOCA... | $0 | $0 | Dec 9, 2025 |
| Oct 28, 2024 | 39128676X | RESOLVE | CLASS - 2 | OBSERVED PAINTED SPRINKLER CAPS THROUGHOUT BUILDING. AS PER 102.3 OF THE PLUMBING CODE MAINTENANCE. INSTALLATIONS, BO... | $0 | $0 | Feb 11, 2025 |
| Oct 28, 2024 | 39128685H | RESOLVE | CLASS - 2 | I OBSERVED IN THE LAUNDRY ROOM AND THE BASEMENT PANTRY THE FAILURE TO PROVIDE GFCI PROTECTION FOR A RECEPTACLE INSTAL... | $1,200 | $0 | Feb 11, 2025 |
| Oct 28, 2024 | 39128675Y | RESOLVE | CLASS - 2 | OBSERVED 2 PAINTED SPRINKLER HEADS IN THE WATER HEATER ROOM LOCATED AT BASEMENT. ALSO OBSERVED OBSTRUCTED SPRINKLER H... | $310 | $0 | Jan 7, 2025 |
| Oct 28, 2024 | 39128684X | RESOLVE | CLASS - 1 | I OBSERVED THE EMERGENCY SWITCH AND PANEL FOR THE BACKUP GENERATOR INSTALLED IN THE MAIN ELECTRICAL ROOM AS BC 2702.1... | $2,500 | $0 | Feb 11, 2025 |
| May 29, 2024 | 39115420J | RESOLVE | CLASS - 1 | MAIN BRAKE PICKING AND DROPPING IN THE LOBBY. DEVICE OSCILLATING UP AND DOWN WITH THE DOOR OPEN(CU). MUST HAVE THE CA... | $1,250 | $0 | Dec 17, 2024 |
| Feb 23, 2024 | 39106767Y | RESOLVE | CLASS - 1 | ONLY ELEVATOR IN THE BUILDING OUT OF SERVICE. RESTORED TO SERVICE IMMEDIATELY. YOU CAN CONTACT NYCDOB AT EIR@BUILDING... | $0 | $0 | Mar 25, 2025 |
| Jan 18, 2024 | 39103749R | RESOLVE | CLASS - 1 | DOOR ZONE RESTRICTOR NOT WORKING TAMPERED WITH DISABLED. THE CAR DOOR CAN BE OPENED OUTSIDE THE LANDING ZONE(CU). RUS... | $3,125 | $0 | Mar 26, 2024 |
| Jan 25, 2023 | 39078441Z | RESOLVE | CLASS - 1 | DOOR ZONE RESTRICTOR NOT WOKING TAMPERED WITH . CAR DOOR CAN BE OPENED OUTSIDE OF THE LANDING ZONE (CU). | $1,280 | $0 | Aug 22, 2023 |
| Oct 10, 2019 | 35392798L | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #39006641K ISSUED ON 07-29-2019 AND TO ... | $1,250 | $0 | Dec 24, 2019 |
| Sep 9, 2019 | 38271307X | RESOLVE | CLASS - 1 | CEASE USE 5-A-10 DOOR ZONE RESTRUCTOR NOT WORKING THIS IS A SAFETY DEVICE TO ENSURE PASSENGERS SAFETY REPAIR RESTRICT... | $3,125 | -$3,125 | Nov 26, 2019 |
| Jul 29, 2019 | 39006641K | RESOLVE | CLASS - 1 | OBSERVED AT FIRE DEPARTMENT CONNECTION NO BALL DRIP LOCATED., REPAIR AND/REPLACE | $1,250 | $0 | Sep 17, 2019 |
| Jul 30, 2013 | 34904350N | RESOLVE | CLASS - 1 | FAILURE TO PERFORM SPECIAL INSPECTION DUTIES, AS NOTED: AT TIME OF IN-SPECTION,STEEL BUILDING ERECTED TO 7STORIES FLO... | $1,600 | $0 | Nov 26, 2013 |
| Jun 18, 2013 | 34904300P | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM GO APPROVED CONSTRUCTION DOCUMENT OR APPROVED AMENDMENTS.AS NOTED:WORK DOES NOT CONFORM TO APPR... | $1,000 | $0 | Nov 19, 2013 |
| Apr 22, 2013 | 34904212P | RESOLVE | CLASS - 2 | SEC. 3307.5.1 FAILURE TO PROVIDE A WATCH PERSON ON DUTY AT CONSTRUCTION SITE. AS NOTED: AT TIME OF INSPECTION CONSTRU... | $0 | $0 | Jun 11, 2013 |
| Apr 19, 2013 | 34904211N | RESOLVE | CLASS - 2 | SEC. 28-105.5 FORMS FILED W/DOB'S DO NOT HAVE REQUIRED SIGNATURES. RE-INSPECTION CALL CEU AT 212-676-9971 AS NOTED: T... | $0 | $0 | Jun 11, 2013 |
| Aug 6, 2012 | 34779026L | RESOLVE | CLASS - 1 | STORAGE OF MATERIALS DURING CONSTRUCTION. AS NOTED: AT TIME OF INSPECTION AT AN ACTIVE CONSTRUCTION SITE,STRUCTURAL S... | $2,400 | $0 | Nov 27, 2012 |
| Aug 6, 2012 | 34779025J | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATION. AS NOTED: AT TIME OF INSPECTION AT AN... | $2,400 | $0 | Nov 27, 2012 |
| Aug 6, 2012 | 34778974R | RESOLVE | CLASS - 1 | SEC. 3308.3 FAILURE TO PROVIDE VERTICAL SAFETY NETTING REQUIREMENTS. AS NOTED: AT TIME OF INSPECTION AT AN ACTIVE CON... | $1,600 | $0 | Nov 27, 2012 |
| Aug 6, 2012 | 34779027N | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENT. AS NOTED: AT TIME OF INSPECTION AT AN ACTIVE CONST... | $800 | $0 | Nov 27, 2012 |
| Aug 6, 2012 | 34778973P | RESOLVE | CLASS - 1 | SEC. 3308.1.3 FAILURE TO PROVIDE HORIZONTAL NETTING DURING NEW CONSTRUCTION & STRUCTURAL ADDITION. AS NOTED: AT TIME ... | $1,600 | $0 | Nov 27, 2012 |
| Aug 3, 2012 | 34778972N | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURE OR TEMPORARY CONSTRUCTION,NO GUARDRAILS. AS NOTED: AT TIME OF ... | $2,400 | $0 | Nov 27, 2012 |
| Jun 13, 2012 | 34942413Z | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS AT JOB SITE AT TIME OF INSPECTION. NOTED: AT 7 STORY PROPOSED STEEL FRAME ... | $0 | $0 | Jul 31, 2012 |
| Jun 13, 2012 | 34942414K | RESOLVE | CLASS - 1 | SEC. 3307.3. OVERHEAD PROTECTION FOR WALKWAY AND SIDEWALK. NOTED: AT ACTIVE CONSTRUCTION SITE, AT EXP 4, 5TH FLR UNFI... | $1,600 | $0 | Oct 9, 2012 |
| Apr 17, 2012 | 34778823J | RESOLVE | CLASS - 2 | GENERAL CONTRACTORS REGISTRATION HAS EXPIRED. NOTED: N.B. UNDER CONSTRUCTION UNDER APPLICATION #410134224 W/RESPONDEN... | $250 | $0 | Jun 5, 2012 |
| Apr 13, 2012 | 34951215M | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS: NOTED: UNDER JOB #410134224N.B. PROP... | $1,200 | $0 | May 29, 2012 |
| Oct 18, 2011 | 34931243L | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. NOTED: WORK AT PREMISES UNDER PERMIT... | $1,200 | $0 | Dec 13, 2011 |
| Oct 5, 2011 | 34931015J | RESOLVE | CLASS - 1 | NOTED ERECTING SHEATING AND SHORING APPX 13FT DEEP AND APPX 350 LINEAR FT LONG REM: STOP ALL WORK OBTAIN PERMIT | $800 | $0 | Apr 24, 2012 |