Hillcrest High School, Queens • Block 09774 • Lot 0001

167 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
May 5, 2014 35093994Z RESOLVE CLASS - 2 RE-ISSUE # 35023741R. OCCUPANCY CONTRARY TO THAT ALLOWED BY TCO 1822284 EXPIRED ON 4/13/72. 3RD FLOOR ROOF OCCUPIED W... $0 $0 Jul 29, 2014
May 5, 2014 35093992P RESOLVE CLASS - 2 RE-ISSUE # 34958532H. RETAINING WALL AT SIDE & REAR OF BUILDING 6'HIGH HAS MISSING/LOOSE MORTAR JOINTS, ALSO SPALLING... $0 $0 Jul 29, 2014
Jul 16, 2013 35023741R RESOLVE CLASS - 2 REISSUE 34980964M 3 FLOOR ROOF OCCUPIED W/SEATING FOR OVER 120 PERSONS APPROX 20 TABLES IN PLACE. NB-2449/1966 TCO 18... $0 $0 Sep 17, 2013
Jul 16, 2013 35023743K ACTIVE CLASS - 2 REISSUE 34958532H RETAINING WALL 6'HIGH ALONG SIDE/REAR OF BUILDING JOINTS MISSING/BRICKS SPALLING. RMDY: REPAIR WALL. $0 $0 Sep 17, 2013
Jul 16, 2013 35023742Z RESOLVE CLASS - 2 REISSUE 34958535N BANNERS HANGING FROM CEILING AT MAIN ENTRANCE OBSTRUCTING EXIT SIGNS 1 FLOOR. RMDY: REMOVE BANNERS. $0 $0 Sep 17, 2013
Jul 16, 2013 35023744M RESOLVE CLASS - 2 EXIT PASSAGEWAY OBSTRUCTION AT 3 FLOOR SUMMER CLEANING IN PROGRESS ADJACENT TO ACTIVE SUMMER CLASSES, ALSO EXIT 1/2 V... $0 $0 Sep 17, 2013
Jul 10, 2013 35023732P RESOLVE CLASS - 2 REISSUE 34827889K SINK HOLE AT REAR PLAY YARD ADJACENT TO RETAINING WALL,HOLLOW SPACE AROUND BASIN. REMEDY: MAKE SAFE. $0 $0 Sep 17, 2013
May 22, 2012 34958535N RESOLVE CLASS - 2 BANNERS HANGING FROM CEILING IN THE CORRIDOR IS OBSTRUCTUNG/BLOCKING THE EXIT SIGN LOCATED @ THE MAIN ENTRANCE (1 FLR... $0 $0 Aug 14, 2012
May 22, 2012 34980964M RESOLVE CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERT OF OCCUPANCY.NOTED:3 FLR ROOF TERRACE IS ARRANGED FOR APPROX 120 SEATI... $0 $0 Aug 14, 2012
May 22, 2012 34958532H ACTIVE CLASS - 2 REISSUE:34908642N.BRICK WALL APPROX 6' TALL IS MISSING MORTAR BTWN BRICKS LOCATED IN BTWN THE SCHOOL & BASEBALL FIELD... $0 $0 Aug 14, 2012
May 22, 2012 34958534L RESOLVE CLASS - 2 THE PLASTER ON THE WALL & CEILING IS SPALLING.LOCATED @ EXIT E & F ON THE 1 FLR LEVEL.REM:REPAIR &/OR REPLACE PLASTER. $0 $0 Aug 14, 2012
May 16, 2012 34953968X RESOLVE CLASS - 2 REISSUE:34827889K & 34905941J REAR PAVEMENT IS SINKING CAUING A SINK HOLE ADJACENT TO THE RETAINING WALL & ROOM 137 @... $0 $0 Jul 17, 2012
May 16, 2012 34953967Y RESOLVE CLASS - 2 REISSUE:34905942L.FOUNDATION WALL HAS BECOME POROUS & ALLOWING RAIN WATER INTO THE ELECTRICAL ROOM CAUSING INTERIOR D... $0 $0 Jul 17, 2012
Apr 20, 2011 34908642N ACTIVE CLASS - 2 EXTERIOR BRICK WALL IS MISSING MORTAR BTWN THE BRICK LOCATED BTWN THE SCHOOL & SCHOOL YARD REM: REPAIR BRICK WALL $0 $0 Jun 14, 2011
Mar 30, 2011 34905942L RESOLVE CLASS - 2 EXTERIOR FOUNDATION WALL HAS BECOME POROUS & ALLOWING RAIN WATER TO ENTER THE ELECTRICAL ROOM CAUSING INTERIOR DAMAGE... $0 $0 May 17, 2011
Mar 30, 2011 34905941J RESOLVE CLASS - 2 REISSUE: 34827889K EXTERIOR PLAY YARD IS SINKING CAUSING A SINK HOLE ADJACENT TO THE RETAINING WALL (4' FT HIGH) REM:... $0 $0 May 17, 2011
Jan 15, 2010 34827889K RESOLVE CLASS - 2 Q086 NOTED MAJOR TRIP HAZARDS AT REAR PLAY YARD 7 FRT ADJACENT TO RETAINNING WALL FRT OF ROOM 137 SETTING OF GROUND C... $0 $0 Apr 20, 2010
Jan 13, 2010 34827885N RESOLVE CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY NOTED MAIN ENTRANCE RAILINGS IN PLACE RIGHT IN FRONT OF EXIT DOORS OB... $0 $0 Apr 20, 2010
Feb 26, 2009 34761669J RESOLVE CLASS - 2 INTERIOR CLASSROOM DOOR CHECK IS DEFECTIVE NOTED DOOR CHECK IS NOT ATTACHED TO THE FRAME IN ROOM 237 ON THE 2ND FL RE... $0 $0 May 12, 2009
Feb 26, 2009 34761667X RESOLVE CLASS - 2 THE PLASTER IS SPALLING ON THE WALL & CEILING LOCATED AT EXIT 6 AUDITORIUM 1ST FL LVL & STAIRCASE C BETWEEN 1ST & BSM... $0 $0 May 12, 2009
Feb 26, 2009 34761668H RESOLVE CLASS - 2 THE ELECTRICAL ROOM IS LACKING FIRESTOPPING BETWEEN PIPES & WALL AT CELLAR LVL REM: PROVIDE FIRE STOPPING IN ELECTRIC... $0 $0 May 12, 2009
Feb 17, 2009 34761463Y RESOLVE CLASS - 2 NO FIRE-STOPPING PROVIDED AT THE ELECTRICAL ROOM (B26) LOCATED AT THE PIPE PENETRATION GOING THROUGH THE WALLS ABOVE ... $0 $0 May 12, 2009
Feb 17, 2009 34761461K RESOLVE CLASS - 2 GYMNASIUM WOODEN FLOOR IS ROTTEN & LOOSE ON THE 1ST FL LEVEL BY THE MAIN ENTRANCE. REMEDY: REPAIR/REPLACE GYMNASIUM F... $0 $0 May 12, 2009
Feb 17, 2009 34761462M RESOLVE CLASS - 2 THE HANDBALL COURT CONCRETE WALL IS SPALLING LEAVING OPEN UNEVEN SPOTSAT THE REAR OF THE SCHOOL. REMEDY: REPAIR/REPLA... $0 $0 May 12, 2009
Sep 15, 2008 34698825N RESOLVE CLASS - 2 ONE SET OF THE EXIT DOORS IS MISSING. PANIC HARDWARE LOCATED IN THE AUDITORIUM 1ST FLR LEVEL. EXIT DOORS HAS DOOR KNO... $0 $0 Dec 16, 2008
Aug 11, 2008 34697919J RESOLVE CLASS - 2 REISSUE: 34577262H FAILURE TO MAINTAIN BUILDING WALL OR APPURTENANCES.NOTED: EXTERIOR BRICK FACADE HAS SEVERAL CRACKS... $0 $0 Nov 18, 2008
Jun 21, 2007 34577597J RESOLVE Hazardous SEC.27-334.MISSING PROTECTIVE GUARDS AT ROOF.CENTER OF ROOF ONLY A 1 1/2" COPING STONE EXISTS AROUND EDGE WITH A APRO... $0 $0 Aug 14, 2007
Jun 21, 2007 34577262H RESOLVE Hazardous REISSUE #34400840R CRACKS IN BRICKS & MISSING MORTAR LOCATED AT FRONT WEST FACADE & 3FL OUTSIDE OF RM #334 EAST FACAD... $0 $0 Aug 14, 2007
Jun 21, 2007 34577599N RESOLVE Hazardous WATER PENETRATION THROUGH EXTERIOR WALL INTO ROOM #250,280B,334 7 AT BOILER ROOM TUNNEL TO PS 86.REMEDY:STOP WATER PE... $0 $0 Aug 14, 2007
Jun 21, 2007 34577598L RESOLVE Hazardous MISSING & SPALLING PLASTER ON WALL AT 2FL ROOMS 250,280B & 3FL ROOM 334.REMEDY:REPAIR PLASTER. $0 $0 Aug 14, 2007
May 24, 2006 34400840R RESOLVE Non-Hazardous REISSUE VI 34481976N CRACKS IN BRICKS & MORTAR MISSING LOCATION FRONT WEST FACADE 3RD FL OUTISDE OF RM 334 EAST FACAD... $0 $0 Aug 15, 2006
May 24, 2006 34526927N RESOLVE Hazardous REISSUE:#34481979Z DOORS & FRAMES AT EXIT IN DISREPAIR W/ ROTTING,SPLITTING & MISSING STEEL AT BOTTOM SUPPPORTS LOCAT... $0 $0 Aug 15, 2006
May 24, 2006 34526926L RESOLVE Hazardous REISSUE:#34481978R DEFECTIVE PLASTER & SHEET ROCK WITH SPALLING CRACK & HOLES LOCATION RMS 250 280B, STAIRS #3/4 3RD ... $0 $0 Aug 15, 2006
May 24, 2006 34526925J RESOLVE Hazardous REISSUE:#34481977P WATER PENETRATION & LEAKS THROUGH EXTERIOR WALL LOCATION RM 250,280B,STAIR #3/4 AT 3RD & 4FL LANDI... $0 $0 Aug 15, 2006
May 24, 2006 34400836Y RESOLVE Non-Hazardous REISSUE VI 34475320J CRACK & SPALLING PLASTER OF WALL CEILING LOCATIONSTAIR# 4 1ST FL & BSMT TO 1ST FLR & 3FL THROUGH... $0 $0 Aug 15, 2006
Jul 5, 2005 34481978R RESOLVE Non-Hazardous DEFECTIVE PLASTER & SHEETROCK WITH SPALLING CRACKS HOLES LOCAITON RM#250 280B STAIR #3/4 @ 3RD & 4TH FL LANDINGS R334... $0 $0 Aug 16, 2005
May 3, 2005 34481977P RESOLVE Non-Hazardous WATER PENETRATION & LEAKS THROUGH EXTERIOR WALLS LOCATION RM# 250, 280B STAIR # 3/4 AT 3RD & 4TH FLOOR LANDINGS R334 ... $0 $0 Aug 16, 2005
May 3, 2005 34481976N RESOLVE Hazardous CRACKS IN BRICKS & MORTAR MISSING LOCAITON:FRONT WEST FACDE 3RD FLOOR OUTSIDE OF RM 334 EAST FACADE 2-4 FLS OVER ALLE... $0 $0 Aug 16, 2005
May 3, 2005 34481979Z RESOLVE Non-Hazardous DOORS & FRAMES AT EXITS AT EXITS IN DISREPAIR WITH ROTTING SPLITTING & MISSING STEEL AT BOTTOM SUPPORTS LOCATIONS:EXI... $0 $0 Aug 16, 2005
May 2, 2005 34475320J RESOLVE Non-Hazardous REISSUE #347308523L CRACKS & SPALLING PLASTER OF WALLS & CEILING LOCATIONS: STAIR # 4 1ST FL & BASEMENT TO 1ST FLOOR ... $0 $0 Aug 16, 2005
May 2, 2005 34475319M RESOLVE Non-Hazardous WATER PENETRATION THROUGH ROOF & INFO WINDOWS ROOFS IN DISREPAIR WITH MISSING INSULATION & GRAVEL LOCATION THROUGH 3R... $0 $0 Aug 16, 2005
Mar 26, 2003 34383298Y RESOLVE Non-Hazardous FAILURE TO MAINTAIN BUILDING. DEFECT LEAKY ROOF OVER ROOMS: 42D,430B-E44D,450,452,460,480B-E,484,490,465. MAKE ALL RE... $0 $0 Jun 24, 2003
Jan 25, 2002 34308523L RESOLVE Non-Hazardous FAILURE TO MAINTAIN DEFECT ARE ROOF LEAKS CAUSING PLASTER TO PEAL AT STAIRCASE 1AT 3 1/2 LANDING AND STAIR 4 AT 1ST F... $0 $0 Apr 9, 2002
May 25, 2001 38114531L RESOLVE Non-Hazardous 73X07. 73- FAILURE TO REPORT ACCIDNET AS PER SECTION 27-1006. $0 $0 Jul 10, 2001
Mar 1, 2001 34280049L RESOLVE Non-Hazardous FAILURE TO PROVIDE 3" FLOOR NUMBER SIGNS AT STAIR LANDING ON ALL FLOORS.FAILURE TO PROVIDE 3" LETTER STAIR I.D. SIGNS... $0 $0 Apr 17, 2001
Mar 1, 2001 34280048J RESOLVE Non-Hazardous FAILURE TO PROVIDE ADEQUATE EMERGENCY POWER EXIT LIGHTS ON THE 2ND AND3RD FLOOR AND STAIRS.FAILURE TO PROVIDE EMERGEN... $0 $0 Apr 17, 2001
Jan 30, 2001 34257119M RESOLVE Non-Hazardous FAILURE TO MAINTAIN BUILDING EXTERIOR WALL DEFECTS ARE CRACK ON EXTERIOR BRICKWALL ON SOUTH EAST RETURN,WEST OF EXIT ... $0 $0 Apr 24, 2001
Jan 30, 2001 34257301Z RESOLVE Non-Hazardous FAILURE TO MAINTAIN BUILDING:DEFECTS ARE DAMAGED FLOORING IN RM 250 AND AROUND NEWEL POST ON STAIR 5/4 O 14FL.REMEDY:... $0 $0 Apr 24, 2001
Jan 30, 2001 34257118K RESOLVE Hazardous FAILURE TO MAINTAIN BUILDING DEFECTS ARE ROOF LEAKS INTO RMS 302,332,338,STAIR 1 AND 31/2 LANDING STAIR 4 AND 1ST PL ... $0 $0 Apr 24, 2001
Jan 30, 2001 34257303M RESOLVE Non-Hazardous EXIT DOORS A NORTH END OF MAIN LOBBY ENTRANCE ARE NOT SEFL CLOSING.REMEDY:REPLACE/REPAIR DOORS. $0 $0 Apr 24, 2001