168-23-168-45 Jamaica Avenue, Queens • Block 09799 • Lot 0001
38 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jul 7, 2023 | 39089890H | RESOLVE | CLASS - 1 | DOOR ZONE RESTRICTOR NOT WORKING TAMPERED WITH DISABLED(CU). EMERGENCY ALARM BELL NO BUZZER. EMERGENCY STOP SWITCH NO... | $1,250 | $0 | Jun 25, 2024 |
| May 3, 2023 | 39085384R | RESOLVE | CLASS - 1 | DEVICE NOT RUNNING RESTORE DEVICE BACK TO SERVICE. YOU CAC CONTACT NYCDOB AT EIR@BUILDINGS.NYC.GOV FOR A COMPLETE INS... | $1,250 | $0 | Dec 26, 2023 |
| May 3, 2023 | 39085383P | ACTIVE | CLASS - 1 | DEVICE NOT RUNNING RESTORE DEVICE BACK TO SERVICE. YOU CAN CONTACT NYCDOB AT EIR@BUILDINGS.NYC.GOV FOR A COMPLETE INS... | $6,250 | $0 | Jul 11, 2023 |
| Sep 24, 2021 | 39048149Y | RESOLVE | CLASS - 1 | THE ONLY ELEVATOR IN BUILDING OUT OF SERVICE. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT-OF-SERVICE CREATING A HA... | $1,250 | $0 | Jan 4, 2022 |
| Jun 20, 2017 | 37003582N | RESOLVE | CLASS - 2 | FAILURE TO FILE ANNUAL CERTIFICATION THAT COOLING TOWER 1000005845 HASBEEN INSPECTED,TESTED,AND DISINFECTED AND THAT ... | $1,000 | $0 | Apr 3, 2018 |
| Sep 20, 2011 | 34929014P | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG WALL(S)OR APPURTENANCES.NOTED:OBSERVED @ TIME OF INSPEC.@ ENTIRE EXP.#2 AT 3RD FLR.& PARAPET... | $1,000 | -$1,000 | Nov 15, 2011 |
| Nov 29, 2010 | 38214062X | RESOLVE | CLASS - 2 | 67-X-10,69-M-07,68-M-07/67-X-10-IN CAR EMERGENCY PHONE INOPERATIVE | $250 | $0 | Jan 18, 2011 |
| Aug 23, 2010 | 38212628R | RESOLVE | CLASS - 2 | 99M07,02X10,73O02.(02X10)ALARM BELL INOPERATIVE.(73O02)CLEAN CAR GUIDE RAILS & BRACKETS (FULL). | $500 | $0 | Oct 12, 2010 |
| May 21, 2010 | 34849288M | RESOLVE | CLASS - 2 | ALTERED/CHANGED BUILDING OCCUPIED W/O A VALID C OF O AS PER 28-118.3.1& 28-118.3.2. ALTERATION TYPE 1 JOB #400090753/... | $500 | $0 | Jul 13, 2010 |
| Sep 30, 2009 | 34744984P | RESOLVE | CLASS - 1 | I WENT TO DO A HYDRO TEST AS AN LP APPLICATION BUT FOUND OUT THAT THISIS A DESIGNATED SPRINKLER SYSTEM AND SHOULD HAV... | $400 | $0 | Mar 16, 2010 |
| Jul 23, 2008 | 38188748Y | RESOLVE | CLASS - 2 | 10H11.17H11.16H11.70O02. 10H11 REPLACE WORN CAR DOOR GIBS 17H REPLACE WORN HOISTWAY DOOR GIBS BASEMENT 7 1ST FLS 16H1... | $500 | $0 | Sep 16, 2008 |
| Jul 23, 2008 | 38188747M | RESOLVE | CLASS - 1 | 07L10.17H11.10H11.16H11.70O02. 07L10 REPAIR FRONT & REAR DOOR SAFETY EDGE 17H11 REPLACE WORN BASEMENT & 1ST FL HOISTW... | $1,000 | $0 | Sep 16, 2008 |
| Mar 2, 2007 | 38165225N | RESOLVE | Hazardous | CEASE USE 74L10,77H11,77I11,84#01,80I11,84M07,83O02,86M05(CEASE USE.74L UNIT DOES NOT SHUT DOWN WHEN FIRE SHUTTED CLO... | $2,500 | $0 | Feb 17, 2009 |
| Jan 26, 2007 | 38163977R | RESOLVE | Non-Hazardous | 83.83-ENTIRE DEVICE REMOVED-FILE FOR REMOVAL | $500 | $0 | Aug 7, 2007 |
| Jan 26, 2007 | 38163975N | RESOLVE | Hazardous | CEASE USE.01X10.CALL 212 566 5539 SO COMPLETE INSPE CAN BE DONE | $0 | $0 | Aug 7, 2007 |
| Jan 26, 2007 | 38163976P | RESOLVE | Non-Hazardous | 02X10,12X10.CALL FOR INSPECTION 212 566 5539 SO COMPLETE INSPE CAN BE DONE | $350 | $0 | Aug 7, 2007 |
| Mar 12, 2003 | 38136802L | RESOLVE | Non-Hazardous | CEASE USE 80I11/ 76B01/ 74P17/ 80I LEFT SIDE TOP KICK PLATE DAMAGE 76B ADJUST GAP TOP LEFT 76P CALL DOB 212 566 5524 ... | $500 | $0 | Feb 24, 2004 |
| Oct 2, 2002 | 34324811X | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR SOILDING WALL AT 8 FLOOR MECHANICAL ROOM ACCESSIBLE FROM ROOF LEVEL WEST WALL OF M.R. BR... | $0 | $0 | Nov 19, 2002 |
| Feb 23, 2000 | 38094838K | RESOLVE | Non-Hazardous | 09L11,57O02,:09L CAR DOOR GIBS. | $0 | $0 | Apr 11, 2000 |
| Feb 23, 2000 | 38094837Z | RESOLVE | Non-Hazardous | 67L12,69*01,67L LOWER LANDING REPTREE COMB PLATES 69*ADJUST TENSION O N RIGHT&LEFT SIDE HANDRAILS | $0 | $0 | Apr 11, 2000 |
| Dec 29, 1999 | 34227399Z | RESOLVE | Non-Hazardous | OPERATION OF PLACE OF ASSEMBLY WITHOUT CURRENT PERMIT. NO PUBLIC ASSEMBLY PERMITFOR 200 PEOPLE OCCUPYING WAITING HALL... | $500 | $0 | Feb 8, 2000 |
| Dec 30, 1998 | 34189610K | RESOLVE | Non-Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY HTE CERTIFICATE OF OCCUPANCY 131688 FROM DEPT STORAGE & STORE ON 2 FLOOR DEPT S... | $0 | $0 | Jul 27, 1999 |
| Sep 21, 1998 | 38079381Y | RESOLVE | Non-Hazardous | 69F. | $440 | $0 | Nov 12, 1998 |
| Jul 10, 1998 | 38076288X | RESOLVE | Hazardous | 69B01,72B10,67I12,73T16. (67 ) CEASE USE UNTIL ITEM IS COMPLIED WITH BEFORE RETURNING TO SERVICE. | $500 | $0 | Sep 9, 1998 |
| Nov 28, 1997 | 38067064M | RESOLVE | Non-Hazardous | 73R, 73-FILE THIS DEPARTMENT FOR ILLEGALLY REMOVED DEVICE #4E69 | $350 | $0 | May 19, 1998 |
| Nov 28, 1997 | 38067065Y | RESOLVE | Non-Hazardous | 43U, 43-PERFORM 3YR TEST & TAG | $0 | $0 | Mar 10, 1998 |
| Aug 19, 1995 | 38049689N | RESOLVE | Non-Hazardous | 70E, 70 ELIMINATE SCRAPING ON SIDES. | $100 | $0 | Nov 21, 1995 |
| Jan 19, 1995 | 38046184Y | RESOLVE | Non-Hazardous | 72#72-COMPLY WITH SECTION 805 IN OF THE BUILDING. | $0 | $0 | Mar 7, 1995 |
| Dec 6, 1994 | 38046183M | RESOLVE | Non-Hazardous | 72#. 72-COMPLY WITH SECTION 805-1A OF THE BUILDING C OF O. | $0 | $0 | Feb 28, 1995 |
| Nov 16, 1994 | 38045829H | RESOLVE | Non-Hazardous | 74#. 74#-UPGRADE ESCALATOR TO COMPLY WITH RULE 805.1A OF THE NYC BLDG CODE. | $500 | $0 | Jan 31, 1995 |
| Nov 16, 1994 | 38045830P | RESOLVE | Non-Hazardous | 74#. 74#-UPGRADE ESCALATOR TO COMPLY WITH RULE B05.1A OF THE NYC BLD. CODE. | $200 | $0 | Jan 31, 1995 |
| Sep 13, 1994 | 34106767M | RESOLVE | Non-Hazardous | FAILURE TO FILE A REPORT OF COMPLIANCE WITH LOCAL LAW 16/84-CERTIFYINGTO THE INSTALLATION OF REQUIRED FIRE PROTECTION... | $0 | $0 | Oct 25, 1994 |
| Sep 13, 1994 | 34106766K | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE CUAR IDENTIFICATION OF EXIT STAIRCASE (LETTERS) ANDELEVATOR IDENTIFICATION THROUGHOUT FLOORS & BAS... | $0 | $0 | Oct 25, 1994 |
| Mar 25, 1994 | 38041553H | RESOLVE | Non-Hazardous | 74#, #(74) UP GRADE ESCALATOR TO COMPLY WITH RULE 805.1A OF THE N.Y.C. BLDG. CODE | $500 | $0 | Jun 14, 1994 |
| Nov 3, 1993 | 38038609K | RESOLVE | Non-Hazardous | 73X,74#. 73 RESTORE ESCALATOR TO SERVICE FOR THE PURPOSE OF INSPECTION74 REPLACE MISSING STEPS AND UPGRADE ESCALATOR ... | $100 | $0 | Feb 1, 1994 |
| Oct 29, 1993 | 38038607R | RESOLVE | Non-Hazardous | 73# UPGRADE ESCALATOR TO COMPLY WITH RULE 805.1A OF THE NYC BLDG. CODE | $200 | $0 | Dec 14, 1993 |
| Jun 15, 1992 | 38026364N | RESOLVE | Non-Hazardous | 69#,67L, (69) REMOVE EXCESSIVE SLIPAGE FROM HAND RAIL (67) RENEW BROKEN TEETH-COMB PLATE | $0 | $0 | Jul 28, 1992 |
| Feb 14, 1990 | 34036052H | RESOLVE | Hazardous | USE OF RIGGING EQUIPMENT WITHOUT A SPECIAL RIGGERS LICENSED. USE OF RIGGING EQUIPMENT WITHOUT DANGER SIGNS CORRECTION... | $1,000 | $0 | Apr 3, 1990 |