Issued Violation Status Severity Description Penalty Balance due Hearing
Feb 14, 2026 39550377J RESOLVE CLASS - 2 OBSERVED: UPON VISUAL EXTERIOR INSPECTION, EXPOSURE 1 , SIDEWALK WITH SNOW AND ICE CREATING CONDITIONS OF IMMINENT HA... $0 $0 Apr 21, 2026
Aug 23, 2025 39544005H RESOLVE CLASS - 1 AT TIME OF INSPECTION OBSERVED: PROPOSED 9 STORY NEW BUILDING AT 1ST FL. FOOTPRINT APPROX. 5702 SQ. FT. SITE CLOSED A... $0 $0 Apr 20, 2026
Jul 3, 2025 39541967P RESOLVE CLASS - 2 EXP4 OBSERVED REBAR COLUMNS HEIGHT 12 FEET ABOVE FENCE LINE WITH MISSING SWS REQ.PER BC3307.6.2 STIPULATES SWS SHALL ... $0 $0 Sep 9, 2025
May 1, 2025 39539699P RESOLVE CLASS - 1 DURING INSPECTION OF AN ACTIVE SITE AT EXCAVATION PHASE I OBSERVED THAT THERE WERE NO GUARDRAILS IN PLACE AROUND THE ... $5,000 $0 Dec 8, 2025
Jun 14, 2024 39117093K RESOLVE CLASS - 2 EXPIRED PERMIT.JOB SITE FENCE PERMIT#Q00568756-I1-FN EXPIRED 05/03/2023., RENEW PERMIT $0 $0 Aug 27, 2024
Apr 14, 2023 39515363P RESOLVE CLASS - 2 AT THE TIME OF INSPECTION OF AN INACTIVE JOBSITE I OBSERVED THAT THE FENCE HAD MISSING OR COVERED VIEWING PANELS THRO... $1,000 $0 Nov 21, 2023
Jun 14, 2022 39064061J RESOLVE CLASS - 1 FAILURE TO MAINTAIN/INSTITUTE SAFETY MEASURES: UNSAFE ACCESS TO EXCAVATION. AT TIME OF INSPECTION OBSERVED EXCAVATION... $2,500 $0 Aug 30, 2022
Jun 14, 2022 39064060H RESOLVE CLASS - 1 FAILURE TO PROTECT SIDES OF EXCAVATION. AT TIME OF INSPECTION OBSERVED ONGOING EXCAVATION WORK WHERE EXCAVATION HAS R... $5,000 $0 Aug 30, 2022
Jul 13, 2021 35580503N RESOLVE CLASS - 2 TEMPORARY CONSTRUCTION EQUIPEMENT ON SITE-EXPIRED PERMIT.AT TIME OF INSPECTION ON CLOSED SITE OF DEMOLISHED 1 STORY B... $625 $0 Dec 14, 2021
Jun 23, 2021 35557480Y RESOLVE CLASS - 2 CONST FENCE PERMIT EXPIRED.OBSERVED SITE CLOSED,FENCE ON EXP1,4&PARTIAL ON EXP3,2.UPON RESEARCH ON DOBNOW I NOTED FEN... $625 $0 Sep 14, 2021
Sep 17, 2020 35503142H RESOLVE CLASS - 2 JOB SITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBSECTION.ATTIME OF INSPECTION OBSERVED FENCE NOT MAINTAINE... $1,030 $0 Dec 8, 2020
Jun 8, 2016 32076893X RESOLVE CLASS - 2 B265. AS PER CLASS 2 ( B265) 28-303.7 FAILURE TO FILE A COMPLETE BOILER INSPECTION REPORT AS PER DOB RECORDS. SUBMIT ... $2,500 $0 Jul 26, 2016