ECB violations

84 Avenue, Queens • Block 09858 • Lot 0100

144 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Aug 26, 2014 35108115M RESOLVE CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONST OPERATIONS.APPL #402890715 NOTED MULTIPLE UNSECURE(STOR... $2,400 $0 Dec 9, 2014
Aug 26, 2014 35108116Y RESOLVE CLASS - 2 28-105.12.8,WORK NOT IN CONFORMANCE W/ SIDE SAFETY PLAN P.A PLAN FOR APPLICATION 402890715,PLAN CALLS FOR A CLEAR PAS... $400 $0 Dec 9, 2014
Jul 24, 2013 35027939K RESOLVE CLASS - 2 DEFECTIVE DOORS AT 3 FLR CORRIDOR DOORS NEAR ROOMS 328,318, 2 FLR CORRIDOR DOORS NEAR 226, 1ST FLR CORRIDOR DOORS NEA... $0 $0 Sep 17, 2013
Jul 24, 2013 35027938Z RESOLVE CLASS - 2 SPALLING/CRACKED DECORATIVE STONES THROUGHOUT BLDG FACADE. REMEDY: MAKE SAFE! $0 $0 Sep 17, 2013
Jul 24, 2013 35027937R RESOLVE CLASS - 2 REISSUE 34908636R, 34958063Y. PLASTER DAMAGE AT ROOMS 4TH FLR DANCE RM, 323,339,340,336,232, 1ST FLR WEST BOYS ROOM. ... $0 $0 Sep 17, 2013
Jul 24, 2013 35027936P RESOLVE CLASS - 2 REISSUE 34958062M. STONE WALLS LOCATED THROUGHOUT STAIRS, SEVERE CRUMBLING, STONES DISLODGED, MORTAR MISSING. REMEDY:... $0 $0 Sep 17, 2013
Jul 24, 2013 35027940H RESOLVE CLASS - 3 DEFECTIVE BLOWERS ON 4TH FLR FEEDING ROOMS 401,402,403 NOT OPERATIONALAT TIME OF INSPECTION, SOLE VENTILATION THESE R... $0 $0 Sep 17, 2013
May 31, 2012 34958065H RESOLVE CLASS - 2 REISSUE 34828095N THE 15'FT RETAINING WALL ADJACENT TO 85 AVE ND 4'FT WALL ON 85 AVE IS CRACKED AND SPALLING LEAVING ... $0 $0 Aug 14, 2012
May 31, 2012 34958064X RESOLVE CLASS - 2 REISSUE 34908636R THE CEILING PLASTER IS SPALLING LOCATED IN ROOM 323 3RD FLOOR LVL REM: REPAIR AND/OR REPLACE PLASTER $0 $0 Aug 14, 2012
May 31, 2012 34958062M RESOLVE CLASS - 2 REISSUED 34586723X 34908633L STONE WALL AT THE MAIN ENTRANCE APPX 2'FT HIGH IS MISSIG STONE REM; REPLACE MISSING STONES $0 $0 Aug 14, 2012
May 31, 2012 34958063Y RESOLVE CLASS - 2 REISSUED 34908634N THE PLASTER ON THE CEILING OUTSIDE THE DANCE ROOM ON THE 4TH FLOOR IS SPALLING AND LEAVING A HOLE ... $0 $0 Aug 14, 2012
May 31, 2012 34958061K RESOLVE CLASS - 2 REISSUE 34474765H 34908632J THE CONCRETE WALLS AND CEILING UNDER THE POOL IS CRACKED LOCATED AT THE CELLAR LVL REBARS... $0 $0 Aug 14, 2012
Apr 19, 2011 34908631H RESOLVE CLASS - 2 REISSUE 34828083X EXTERIOR CONCRETE STEPS ARE SINKING APPX 5" TO 6" INCHES LOCATED BY EXIT 2/3 ON THE 1ST FLOOR LVL R... $0 $0 Jun 14, 2011
Apr 19, 2011 34908637Z RESOLVE CLASS - 2 REISSUE 34828095N EXTERIOR 15'FT HIGH RETAINING WALL HAS A VERTICAL CRACKED FROM TOP TO BOTTOM ADJACENT TO 85AVE REM:... $0 $0 Jun 14, 2011
Apr 19, 2011 34908633L RESOLVE CLASS - 2 REISSUE 34828085J EXTERIOR STONE WALL APPX 2'FT TALL IS MISSING STONESLOCATED AT THE MAIN ENTRANCE REM: REPLACE MISSI... $0 $0 Jun 14, 2011
Apr 19, 2011 34908632J RESOLVE CLASS - 2 REISSUE 34828084H THE CONCRETE WALLS & BRICK COLUMNS ARE VERTICALLY CRACKED LOCATED IN THE POOL MACHINE ROOM AT THE C... $0 $0 Jun 14, 2011
Apr 19, 2011 34908634N RESOLVE CLASS - 2 REISSUE 34828086L THE PLASTER ON THE CEILING IS SPALLING LOCATED IN THE DANCE ROOM ON THE 3RD FLOOR LVL REM: REPAIR R... $0 $0 Jun 14, 2011
Apr 19, 2011 34908635P RESOLVE CLASS - 2 REISSUE 34828088P THE CONCRETE ABOVE THE ENTRANCE WAY ADJACENT TO THE ELEVATOR IS CRACKED & SPALLING AT THE CELLAR LV... $0 $0 Jun 14, 2011
Apr 19, 2011 34908636R RESOLVE CLASS - 2 THE PLASTER ON THE WALL AND CEILING IS SPALLING LOCATED IN ROOM 323 ON THE 3RD FLOOR LVL REM: REPAIR & /OR REPLACE PL... $0 $0 Jun 14, 2011
Feb 1, 2010 34828095N RESOLVE CLASS - 2 EXTERIOR CONCRETE RETAINING WALL IS CRACKED & SPALLING LOCATED NEXT TO85 AVENUE.RETAINING WALL IS APPROXIMATELY 15'FT... $0 $0 Apr 20, 2010
Jan 27, 2010 34828085J RESOLVE CLASS - 2 REISSUE:34586723X,34761903Z,34692382X EXTERIOR STONE WALL IS MISSING STONES LOCATED @ THE MAIN ENTRANCE.NOTED:STONE W... $0 $0 Apr 20, 2010
Jan 27, 2010 34828088P RESOLVE CLASS - 2 REISSUE:34692389Z CONCRETE ABOVE ENTRANCE WAY NEXT TO ELEVATOR IS CRACKED & SPALLING LOCATED IN THE BOILER ROOM.REM-R... $0 $0 Apr 20, 2010
Jan 27, 2010 34828086L RESOLVE CLASS - 2 REISSUE:34586725 INTERIOR PLASTER ON THE CEILING IS SPALLING/CRACKED &MISSING LOCATED @ THE 3RD FL DANCE ROOM.REM-REP... $0 $0 Apr 20, 2010
Jan 27, 2010 34828090Y RESOLVE CLASS - 1 THE MAIN ENTRANCE IS BEING OBSTRUCTED BY SECURITY SCANNERS,POLES,SECURITY OFFICER DESK,LINE RIBBONS ON THE 1ST FL.REM... $0 $0 Apr 20, 2010
Jan 27, 2010 34828089R RESOLVE CLASS - 2 THE PLASTER IS SPALLING & CRACKED LOCATED IN ROOM 336 & 338 ON THE 3RDFL LEVEL.REM-REPAIR &/OR REPLACE PLASTER.REM-RE... $0 $0 Apr 20, 2010
Jan 27, 2010 34828087N RESOLVE CLASS - 2 REISSUE:347617735,34692388R,THE ELECTRICAL ROOM IS LACKING FIRE STOPPING AROUND THE PIPE PENETRATION @ CELLAR LEVEL.R... $0 $0 Apr 20, 2010
Jan 27, 2010 34828084H RESOLVE CLASS - 2 REISSUE:34474765H,34474767L,34761901P INTERIOR WALLS & BRICK COLUMN ISVERTICALLY CRACKED & SPALLING LOCATED @ THE POO... $0 $0 Apr 20, 2010
Jan 27, 2010 34828083X RESOLVE CLASS - 2 REISSUE:347619902R EXTERIOR CONCRETE STEPS @ EXIT 2,3 IS SINKING & MISSING LEAVING EXPOSED REPAIRS ON THE 1ST FL LEVE... $0 $0 Apr 20, 2010
Mar 4, 2009 34761903Z RESOLVE CLASS - 2 REISSUE: 34692382X CONCRETE STONE ALL APPRX KNEE HIGH IS MISSING A SECTION W/ MORTAR AT FRONT MAIN ENTRANCE. REMEDY: ... $0 $0 May 12, 2009
Mar 4, 2009 34761773J RESOLVE CLASS - 2 REISSUE: 34692388R THE ELECTRICAL ROOM IS LACKING FIRE STOPPING IN THECELLAR LEVEL LEAVING OPEN GAPS AT THE PIPE PENE... $2,500 $0 May 12, 2009
Mar 4, 2009 34761774L RESOLVE CLASS - 2 REISSUE: 34692387P THE PLASTER ON THE WALL AND CEILING IS SPALLING LOCATED IN ROOM 203 2ND FLR ROOM 316,317,320 ON 3R... $0 $0 May 12, 2009
Mar 4, 2009 34761772H RESOLVE CLASS - 2 REISSUE: 34692389Z CONCRETE WALL ABOVE ENTRANCE DOORWAY NEXT TO FREIGHT ELEVATOR IS SPALLING AT THE BOILER ROOM. REME... $0 $0 May 12, 2009
Mar 4, 2009 34761900N RESOLVE CLASS - 2 REISSUE: 34692386N BRICK FACADE HAS BECOME POROUS AND ALLOWING WATER TO ENTER THE BLDG CAUSING INTERIOR DAMAGES IN RO... $0 $0 May 12, 2009
Mar 4, 2009 34761901P RESOLVE CLASS - 2 REISSUE: 34692384J BRICK COLUMN IS VERTICALLY CRACKED LOCATED AT THE POOL MACHINE ROOM AT BASEMENT LEVEL. REMEDY: REP... $0 $0 May 12, 2009
Mar 4, 2009 34761902R RESOLVE CLASS - 2 REISSUE: 34692383H CONCRETE STEPS BY EXIT 2 & 3 IS SPALLING AND SINKING LEAVING EXPOSED REBARS ON THE 1ST FLR LEVEL. ... $0 $0 May 12, 2009
Aug 19, 2008 34692388R RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: PIPE PENETRATION GOING THROUGH THE WALL IN THE ELECTRICAL R... $0 $0 Nov 18, 2008
Aug 19, 2008 34692383H RESOLVE CLASS - 2 REISSUE: 34586722Y FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. NOTED: CONCRETE STEP AT ALL ENTRY WAY IS SPALLING... $0 $0 Nov 18, 2008
Aug 19, 2008 34692384J RESOLVE CLASS - 2 REISSUE: 34586726L FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: BRICK COLUMN IS CRACKED VERTICALLY LOCAT... $0 $0 Nov 18, 2008
Aug 19, 2008 34692389Z RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: CONCRETE ENTRANCE DOORWAY NEXT TO ELEVATOR IS SPALLING AT B... $0 $0 Nov 18, 2008
Aug 19, 2008 34692385L RESOLVE CLASS - 2 REISSUE: 34586725J FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: PLASTER IS SPALLING ON THE WALLS AND CEI... $0 $0 Nov 18, 2008
Aug 19, 2008 34692386N RESOLVE CLASS - 2 REISSUE: 34519148Z FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. NOTED: BRICK FACADE HAS BECOME POROUS AND ALLOWIN... $0 $0 Nov 18, 2008
Aug 19, 2008 34692387P RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: PLASTER IS SPALLING IN ROOMS 320,317,316, ON 3RD FLR LEVEL ... $0 $0 Nov 18, 2008
Aug 19, 2008 34692382X RESOLVE CLASS - 2 REISSUE: 34586723X FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. NOTED: CONCRETE STONES AT THE MAIN ENTRANCE WAY I... $0 $0 Nov 18, 2008
Jul 11, 2007 34586725J RESOLVE Non-Hazardous MISSING & SPALLING PLASTER ABOVE GYM INSIDE ACCESSORY BATHROOM & AT BASE OF STAIRS #12/13 & 14/15 AT MACHINE ROOM LEV... $0 $0 Sep 11, 2007
Jul 11, 2007 34586727N RESOLVE Hazardous REISSUE 34400829X.FIELD HOUSE BATHROOMS GIRLS/BOYS/ENGINEERS HAVE VERTICAL STEP CRACK IN BRICKWORK.REMEDY:REPAIR MASO... $0 $0 Sep 11, 2007
Jul 11, 2007 34586722Y RESOLVE Hazardous REISSUE #34400828Y.ALL ENTRY STAIRS AT EXTERIOR ARE CRACKED,SPALLING & MISSING CONCRETE W/ EXPOSED REBAR.REMEDY:REPAI... $0 $0 Sep 11, 2007
Jul 11, 2007 34586723X RESOLVE Hazardous A) STONE KNEE WALL AT MAIN ENTRY STAIRS HAS LOOSE & MISSING STONES & MISSING MORTAR.B) MORTAR MISSING & DISPLACE STON... $0 $0 Sep 11, 2007
Jul 11, 2007 34586726L RESOLVE Hazardous REISSUE #34519147R.SPALLING CONCRETE CRACK IN WALLS & CEILING & BRICK COLOMNS.REMEDY:MAKE ALL NECESSARY REPAIRS. $0 $0 Sep 11, 2007
Jul 6, 2006 32050137P RESOLVE Non-Hazardous 50A,50B,50C.50A-HEAVY SCALE ON STEAM DRUM-REMOVE.50B-CRUMBLING BRICK WORK ON SIDE WALLS & FLOOR HEAVING.50C-INSTALL A... $0 $0 Aug 22, 2006
Jul 6, 2006 32050138R RESOLVE Non-Hazardous 50A,50B,50C.50A-HEAVY SCALE ON STEAM DRUM MUST BE REMOVED.50B-BRICK WORK IN FIRE BOX IN RIGHT SIDE IS FALLING AWAY FR... $0 $0 Aug 22, 2006