ECB violations
Fern Place, Queens • Block 10250 • Lot 0001
79 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Mar 16, 2010 | 34840036P | RESOLVE | CLASS - 1 | EXTERIOR METAL FLASHING @ ROOF LEVEL LEVEL IS LOOSE LOCATED BY THE CHIMNEY STACK (HAZARDOUS)REM:SECURE METAL FLASHING | $0 | $0 | May 18, 2010 |
| Mar 16, 2010 | 34840039K | RESOLVE | CLASS - 2 | BULKHEAD DR IS DEFECTIVE @ ROOF LEVEL (STAIR 'C')NOTED:DR IS SLAMMED SHUT & IS RUBBING UP AGAINT DR FRAME.REM:REPAIR ... | $0 | $0 | May 18, 2010 |
| Mar 16, 2010 | 34840035N | RESOLVE | CLASS - 2 | REISSUE34711803X.EXTERIOR FOUNDATION WALL HAS BECOME POROUS & ALLOWINGRAIN INTO THE ELECTRICAL ROOM CAUSING INTERIOR ... | $0 | $0 | May 18, 2010 |
| Mar 16, 2010 | 34840038Z | RESOLVE | CLASS - 2 | CORRIDOR WIDTH IS PARTIALLY OBSTRUCTED BY RM 307 (3RD FLR LEVEL)BY A HALF OF CIRCLE TABLE.REM:REMOVE OBSTRUCTION | $0 | $0 | May 18, 2010 |
| Mar 16, 2010 | 34840037R | RESOLVE | CLASS - 2 | CORRIDOR SMOKE DRS ARE DEFECTIVE LOCATED BY RM 455 (4TH FLR LEVEL)NOTED:SMOKE DRS HINGE MISSING A SCREW CAUSING DRS T... | $0 | $0 | May 18, 2010 |
| Mar 16, 2010 | 34840034L | RESOLVE | CLASS - 2 | REISSUE:34779836N.INTERIOR PLASTER ON THE WALL IS SPALLING & CRACKED LOCATED IN RM 562,355 & STAIRWAY "C" 4TH FLR LEV... | $0 | $0 | May 18, 2010 |
| Jun 23, 2009 | 34779836N | RESOLVE | CLASS - 3 | WATER PENETRATION THROUGH EXTERIOR WALL INTO RMS 555 562 455 355 URT ROOM & STAIRWAY C 5FL REM: SEAL ALL PENETRATIONS | $0 | $0 | Sep 15, 2009 |
| Oct 16, 2008 | 34711804H | RESOLVE | CLASS - 2 | PLASTER IS SPALLING IN LADIES BATHROOM ON 3RD FLR. REMEDY: REPAIR/REPLACE PLASTER ON WALL. | $0 | $0 | Dec 16, 2008 |
| Oct 16, 2008 | 34711803X | RESOLVE | CLASS - 2 | FOUNDATION WALL HAS BECOME POROUS & ALLOWING RAIN WATER INTO THE BUILDING CAUSING INTERIOR DAMAGE IN THE ELECTRICAL R... | $0 | $0 | Dec 16, 2008 |
| Mar 14, 2007 | 34563964P | RESOLVE | Non-Hazardous | EXIT DOOR NOT SELF CLOSING.DOOR HAS MISSING CLOSER. LOCATION: 2ND FL STAIRWAY-EXIT 5-1 DOOR.REMEDY:REPAIR OR REPLACE ... | $0 | $0 | May 8, 2007 |
| Mar 14, 2007 | 34563968M | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN- INTERIOR CLASS ROOMS T3, T4, T5 HAS CEILING TILE W/ WATER DAMAGE DUE TO LEAKING ROOF. REMEDY : R... | $0 | $0 | Jun 26, 2007 |
| Mar 14, 2007 | 34563965R | RESOLVE | Non-Hazardous | USE OF ILLEGAL HARDWARE. 2ND FL,GYM ENTRANCE-EXITS 2 DOORS,HAVE PASSAGE LOCK HARDWARE OCCUPANCY 480.REMEDY: REMOVE IL... | $0 | $0 | May 8, 2007 |
| Mar 14, 2007 | 34563966Z | RESOLVE | Non-Hazardous | EXIT PASSAGE WAY OR CORRIDOR.REQUIRED WIDTH DECREASED BY OBSTRUCTION FLOORS,2,3,4,5-CORRIDOR WIDTH IS DECREASED BY DE... | $0 | $0 | May 8, 2007 |
| Mar 14, 2007 | 34563967K | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN-EXTERIOR. REISSUE:34519395X. WATER LEAKING THROUGH ROOF INTO THE CLASSROOMS, T3,T4,T5.REMEDY:REPA... | $0 | $0 | May 8, 2007 |
| May 5, 2006 | 34519395X | RESOLVE | Non-Hazardous | WATER PENETRATION THROUGH ROOF INTO CLASS ROOM T3,T4,T5. REMEDY:REPAIRLEAK STOP WATER PENETRATION AT THE ABOVE LOCATION. | $0 | $0 | Aug 15, 2006 |
| May 5, 2006 | 34519393M | RESOLVE | Non-Hazardous | REISSUE VI34475311H WATER PENETRATION THROUGH EXTERIOR BRICK THROUGHOUT. LOCATIONS RMS 507A,307,406A STAIRS 4/5 5FL S... | $0 | $0 | Aug 15, 2006 |
| May 5, 2006 | 34519394Y | RESOLVE | Non-Hazardous | REISSUE VI 34475310X SPALLING DEFECTIVE PLASTER AT WALL & CEILING. LOCATION OF ROOM 507,506 307 406 103 411,414,460,5... | $0 | $0 | Aug 15, 2006 |
| Apr 29, 2005 | 34475311H | RESOLVE | Non-Hazardous | REISSUE 34423208P WATER PENETRATION THROUGH WALLS/CEILING. LOCATIONS. RM'S 507A, 307, 406A STAIRS #4/5 5TH FLOOR STAI... | $0 | $0 | Aug 16, 2005 |
| Apr 29, 2005 | 34475310X | RESOLVE | Non-Hazardous | SPALLING/DEFECTIVE PLASTER AT WALLS AND CEILINGS. LOCATIONS: RM# 507, 506 307, 406 STAIRS 4/5 AT 5TH FLOOR STAIR 6 AT... | $0 | $0 | Aug 16, 2005 |
| Jan 20, 2004 | 34423209R | RESOLVE | Non-Hazardous | FAILURE TO COMPLIED WITH FALSE EXIT REQUIREMENT DEFECTS:ARE INSTALLATION OG EXIT SIGN OVER ROOM 418 DOOR.AT 4TH FLR A... | $0 | $0 | Mar 30, 2004 |
| Jan 20, 2004 | 34423208P | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN:DEFECTS ARE LEAKY EXTERIOR WALLS OVER ROOMS 507A, 406A, 307 AND STAIRS # 4,5,6 ALL FLOORS AND BUL... | $0 | $0 | Mar 30, 2004 |
| Jan 2, 2004 | 34422204N | RESOLVE | Non-Hazardous | USE OF ILLEGAL HARDWARE:EXIT DOORS EQUIPPED WITH DOUBLE KEY LOCKS. LOCATIONS OF DOORS. (1) INTERIOR DOORS MAIN ENTRAN... | $0 | $0 | Mar 30, 2004 |
| Jan 2, 2004 | 34422203L | RESOLVE | Non-Hazardous | USE OF ILLEGAL HARDWARE;EXIT DOORS EQUIPPED WITH SLIDE BOLTS.LOCEKD IN OPEN POSITION AT REAR OF DOOR.LOCATION OF DOOR... | $0 | $0 | Mar 30, 2004 |
| Mar 5, 2003 | 34382916H | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN EXTERIOR BUILDING WALLS. DEFECT IS: LEAKY EXTERIOR WALLS INTO ROOMS: 507A,406A,307A AND STAIRS NO... | $0 | $0 | May 13, 2003 |
| Feb 6, 2001 | 34260916M | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE EMERGENCY LIGHT FIXTURE WITHIN CORRIDOR AND STAIRCASE (5)ON FLOOR 2 TO 5.FAILURE TO PROVIDE POWER ... | $0 | $0 | Apr 17, 2001 |
| Feb 6, 2001 | 34260922Z | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE 3-INCH HIGH ALPHABETIC LETTER SIGN OF IDENTIFICATION,ATTACHED OVER THE OCCUPANCY SIDE OF THE STAIR... | $0 | $0 | Apr 17, 2001 |
| May 12, 1999 | 34205294P | RESOLVE | Hazardous | FAILURE TO MAINTAIN BUILDING INTERIOR. NOTED: 1) NO EMERGENCY LIGHTINGIN STAIRCASES. 2) NO EMERGENCY LIGHTING IN AUDI... | $0 | $0 | Jun 29, 1999 |
| Mar 5, 1999 | 34192600Y | RESOLVE | Hazardous | EXIT DOOR: TOTAL OBSTRUCTION. CLOSED WELL DOOR AND REMOVED STAIRS LEADING FROM BOILER SPACE IN BASEMENT TO 1ST FLOOR.... | $0 | $0 | Apr 20, 1999 |
| Mar 4, 1999 | 34192599X | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT. WORK NOTED: STAIRS LEADING FORM BOILER SPACE INBASEMENT TO 1ST FLOOR THROUGH WELL HAS BEEN REM... | $0 | $0 | Apr 20, 1999 |