Issued Violation Status Severity Description Penalty Balance due Hearing
Feb 20, 2026 39177925Z ACTIVE CLASS - 1 CLASS 1: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. ... $6,250 $6,250 Jun 16, 2026
Jan 14, 2026 39173778J ACTIVE CLASS - 2 IN GARAGE AT SPOT # 14, CONCRETE SPALLING EXPOSING REBAR,ALSO NOTED COLUMN HAS HAIRLINE VERTICAL CRACK., REPAIR AND/O... $6,250 $6,250 Apr 28, 2026
Sep 9, 2025 39159649M ACTIVE CLASS - 1 THE ONLY ELEVATOR IN BUILDING (OR SECTION OF BUILDING) OUT OF SERVICE. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT... $6,250 $0 Dec 23, 2025
Jun 30, 2025 39152302L ACTIVE CLASS - 1 : FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON IN... $1,250 $0 Oct 14, 2025
Feb 27, 2025 39139768R ACTIVE CLASS - 1 NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... $6,250 $0 May 6, 2025
Oct 30, 2024 39128972K ACTIVE CLASS - 1 DLM NOT WORKING. REPAIR. PROVIDE ACCESS TO MACHINE ROOM. $1,250 $0 Feb 11, 2025
Jun 3, 2024 39115842J ACTIVE CLASS - 1 NO DLM INSTALLED ON THIS CONTROLLER AS MANDATED. BY CODE A-17.1 SECTION 3.10.12 OF THE NTCBC 2014 CODE. REPAIR RETURN... $3,125 $0 Aug 13, 2024
Apr 29, 2024 39112966H ACTIVE CLASS - 1 NO DLM INSTALLED ON THIS CONTROLLER AS MANDATED BY CODE A-17.1 OF THE NYCBC 2014 CODE SECTION 3.10.12 . RECURRING CON... $12,500 $0 Jul 9, 2024
Mar 4, 2024 39107652Z ACTIVE CLASS - 1 DOOR ZONE RESTRICTOR NOT WORKING TAMPERED WITH DISABLED(CU). NO DLM INSTALLED ON THIS CONTROLLER AS MANDATED BY CODE ... $3,125 $0 Jun 18, 2024
Jan 25, 2024 39104269M ACTIVE CLASS - 1 NO DLM INSTALLED ON THIS CONTROLLER. AS MANDATED BY NYCBC 2014 BUILDING CODE SECTION 3.10.12. RECURRING CONDITION FIR... $12,500 $0 Nov 12, 2024
Jan 24, 2024 39104258R ACTIVE CLASS - 1 NO DLM INSTALLED ON THIS CONTROLLER . AS MANDATED BY CODE A17.1 SECTION 3.10.12 OF THE NYCBC CODE 2014 RECURRING COND... $3,125 -$3,125 Oct 29, 2024
Dec 20, 2023 39101924X ACTIVE CLASS - 1 (05-A-10) CEASE USE ITEM. DOOR ZONE RESTRICTOR HAS BEEN TAMPERED WITH/ DISABLED AND RENDERED INOPERATIVE. THIS IS A S... $1,250 $0 Mar 26, 2024
Nov 15, 2023 39099448Y ACTIVE CLASS - 1 DLM IS NOT WORKING. REPAIR DLM. LOBBY DOOR RUBBING. ADJUST LOBBY DOOR $1,250 $0 Jan 23, 2024
Sep 5, 2023 39094132P ACTIVE CLASS - 1 NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... $1,250 $0 Dec 12, 2023
May 24, 2023 39087052J ACTIVE CLASS - 1 NO DLM INSTALLED ON THIS CONTROLLER AS MANDATED BY NYCBC 2014 CODE SECTION 3.10.12 K3. $1,250 $0 Aug 1, 2023
Sep 12, 2022 39069836Z ACTIVE CLASS - 1 DLM IMPROPERLY INSTALLED ON THIS DEVICE. NO FIREMANS' SERVICE PRESENT IN CONTROLLER. INSTALL FIREMANS' SERVICE SO DLM... $1,280 $0 Nov 1, 2022
Jul 12, 2022 39065621N ACTIVE CLASS - 1 DOOR ZONE RESTRICTOR NOT WORKING TAMPERED WITH DISABLED(CU). 5TH FLOOR DOOR LOCK DEFECTIVE DOOR INTERLOCK CAN BE OPEN... $1,280 $0 Aug 30, 2022
May 21, 2021 39041701R RESOLVE CLASS - 2 BOILERS OVER 8' IN HEIGHT NEED PLATFORM AND A LADDER, LUGS MISSING FROM REAR CLEAN OUT PLATE, REAR INSPECTION DOOR NO... $0 $0 Jul 13, 2021
Apr 30, 2021 38274040J ACTIVE CLASS - 1 42M7 NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3/10/12 OF APPENDIX (K3) OF THE 2014 NYC BC.... $1,250 $0 Aug 10, 2021
Apr 26, 2021 39040037N ACTIVE CLASS - 1 CEASE USE ITEMS : IN CAR STOP SWITCH INOPERATIVE , REPAIR / ZONE LOCK INOPERATIVE , REPLACE UNIT / NON CEASE USE ITEM... $1,250 $0 Jun 15, 2021
Jun 16, 2020 39023998H RESOLVE CLASS - 1 ONLY ELEVATOR IN THIS SECTION OF BUILDING OUT OF SERVICE RESTORE TO SERVICE $0 $0 Aug 4, 2020
Feb 28, 2019 32098184K RESOLVE CLASS - 2 B254,15,1B, 50A-50D. 50A- CONBUSTION AIR FAN NOT INTERLOCKED WITH BURNER (RUNS CONTINUOUS) 50B-REMOVE OIL CAN FROM BO... $312 $0 May 7, 2019
Jan 22, 2019 35375426X ACTIVE CLASS - 3 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: APART MENT 3-0 WINDOWS HAS BUILDED UP CONDENSATION AROU... $500 $0 Apr 2, 2019
Sep 8, 2018 35387728J RESOLVE CLASS - 1 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #35322981X ISSUED 06/09/18 AND TO FILE... $0 $0 Nov 30, 2018
May 24, 2018 38263430L RESOLVE CLASS - 1 (C/U 5-A-10)DOOR ZONE RESTRICTOR HAS BEEN TAMOERED W/DISABLED & RENDERED INOPERATIVE.THIS IS IS A SAFETY DEVICE TO EN... $2,500 $0 Jul 10, 2018
May 24, 2018 38263429Y RESOLVE CLASS - 2 8-V-1:DEVICE NOT LEVEL IN THE LOBBY & TOP FL. $0 $0 Jul 10, 2018
Mar 13, 2018 38262033N ACTIVE CLASS - 1 5A10,8V1-5A10)DOOR ZONE RESTRICTOR HAS BEEN TAMPERED WITH DISABLED AND RENDERED INOPERATIVE. THIS IS A SAFETY DEVICE ... $1,250 $0 May 1, 2018
Dec 14, 2017 38259987R ACTIVE CLASS - 1 05A10,08V01,40G11-05A10)RESTRICTOR IS NOT OPERATIVE. THIS IS A SAFETY DEVICE. 08V01)PROVIDE ADJUSTMENT FOR LEVEL. 40G... $1,000 $0 Jan 30, 2018
Nov 14, 2017 38258331J RESOLVE CLASS - 2 42H11, 52B14, 64M07, 42H11-REPLACE IDLER BRACKET FOR CONTROLLER SELECTOR 52B14-SHORTEN HOIST CABLES. 64M07 PROVIDE SU... $0 $0 Jan 2, 2018
Oct 25, 2017 38258853R RESOLVE CLASS - 2 8V1,16E1,3H1-8V1)FLOORS OFF LEVEL. 16E1)1ST FLOOR DOOR GETS STUCK. 3H1)LOOSE HANDRAIL. $0 $0 Dec 12, 2017
Feb 1, 2017 35230637Z RESOLVE CLASS - 1 FAILURE TO COMPLY W/ THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION# 35213307L ISSUED ON 11/11/16 & TO FILE ... $2,400 $0 Mar 21, 2017
Dec 9, 2016 38250795L RESOLVE CLASS - 1 05L10, 97V1 05L10 DOOR ZONE RESTRICTOR DEFECTIVE.REPAIR 97V1 DEVICE NOT LEVELON SEVERAL FLOORS.ADJUST $5,000 $0 Jun 20, 2017
Nov 11, 2016 35213307L RESOLVE CLASS - 1 WORK W/O A PERMIT. NOTED: EXCAVATION APPROX 3'DOWN FOOTINGS & CONCRETEWALL ERECTED FRONT STOOP CHOPPED PARTIALLY @ FR... $1,600 $0 Dec 27, 2016
Aug 11, 2016 37001315J RESOLVE CLASS - 2 FAILURE TO SUBMIT ACCEPTABLE 7TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS AND APP... $0 $0 Mar 28, 2017
Jan 5, 2016 38240382Y RESOLVE CLASS - 2 B251.05X10,16L10.05X10:REPAIR DOOR ZONE LOCK.16L10:PULLING 6FL HALLWAY DOOR, CAUSES ELEVATOR TO STOP IN FLIGHT. $0 $0 Feb 23, 2016
Jan 5, 2016 38240383X RESOLVE CLASS - 2 B251.05X10,05L10.0FX10:REPAIR DOOR ZONE LOCK.05L10:REPLACE FRONT CAR DOOR HANGER ROLLER. $0 $0 Feb 23, 2016
Jan 5, 2016 38240384H RESOLVE CLASS - 2 B251.05X10,16L10,08V01.05X10:REPAIR DOOR ZONE LOCK.16L10:PULLING 1ST FL DOOR CAUSE ELEVATOR STOP IN FLIGHT.08V01:1ST ... $0 $0 Feb 23, 2016
Nov 17, 2015 36023348R RESOLVE CLASS - 2 FAILURE TO FILE AN ACCEPTABLE TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS: PERIODIC INSPECTION PF EXTERIOR WALLS... $2,000 $0 Mar 1, 2016
Mar 3, 2015 38235239P RESOLVE CLASS - 2 05M07 PROVIDE DOOR ZONE RESTRICTOR. $0 $0 Apr 21, 2015
Nov 11, 2014 38233460P RESOLVE CLASS - 2 08V01 ELEVATOR NOT STOPPING LEVEL ON NUMEROUS FLOORS. $0 $0 Dec 30, 2014
Nov 11, 2014 38233459H RESOLVE CLASS - 2 08V01 ELEVATOR NOT STOPPING LEVEL AT NUMEROUS FLOORS. $0 $0 Dec 30, 2014
Nov 10, 2014 38233474X ACTIVE CLASS - 2 10H11,59O02,16J01,21D10,05I11,39I11,08V01. 39I11-CAR TOP SHACKLE SPRINGS DAMAGED; 16J01-ADJUST HOISTWAY DOORS FOR SMO... $530 $0 Dec 30, 2014
Jun 9, 2014 36019387H RESOLVE CLASS - 2 FAILURE TO FILE AN ACCEPTABLE CYCLE 7 TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXT... $4,000 $0 Dec 23, 2014
Feb 27, 2014 38230397H RESOLVE CLASS - 2 78H11,68B07. 78H11- REPLACE WORN TENSION SHEAVE BUSHING; 68B7-UPDATE ELEVATOR MAINTENANCE LOGBOOK. $250 $0 Apr 15, 2014
Feb 27, 2014 38230395Y RESOLVE CLASS - 2 42N12,68B07. 42N12-BYPASSED FUSES ON THE CONTROLLER; 67B07-UPDATE ELEVATOR MAINTENANCE LOG BOOK. $250 $0 Apr 15, 2014
Feb 27, 2014 38230396X RESOLVE CLASS - 2 52M07,33I11,68B07. 52M07-PROVIDE SPINOUT DEVICE ON CWT SIDE OF HOIST ROPES SHACKLES; 33I11-REPLACE BROKEN SHACKLE SPR... $250 $0 Apr 15, 2014
Feb 27, 2014 38230398J RESOLVE CLASS - 2 42N11,68B07. 42N11-BYPASSED FUSES ON THE CONTROLLER; 68B07-UPDATE ELEVATOR MAINTENANCE LOGBOOK. $250 $0 Apr 15, 2014
Nov 20, 2013 35067859R ACTIVE CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE BLDG DEPT RECORDS. PREMISES FILE JOB PERMIT #410204363 TO LEGALIZE LAUNDRY ... $1,200 $0 Jan 28, 2014
Nov 9, 2013 38228584K RESOLVE CLASS - 3 08V01 - NOT LEVELING AT LANDING. $200 $0 Jan 28, 2014
Nov 9, 2013 38228583Z RESOLVE CLASS - 2 97X07 - RESTORE TO SERVICE. $500 $0 Jan 28, 2014